Automatic Cutting Needle
18 ga (1.3mm) x 25 cm)
Who Else Makes It
Concentrated in Zhejiang (4), Jiangsu (3), Guangdong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Curaway Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 7 |
| Plexus (Xiamen) Co., Ltd., | Xiamen | Fujian | Contract manufacturer | 3 |
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Zhejiang Huanyi Sterilization Technology Co., Ltd. | Huzhou | Zhejiang | Contract manufacturer | 25 |
| Jiana Sterilization Technology (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 23 |
| Promisemed Hangzhou Meditech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 21 |
| Carbon (Shenzhen) Medical Device Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 6 |
| Canyon Medical Inc. | Nanjing | Jiangsu | Manufacturer | 4 |
| Suzhou Leapmed Healthcare Corporation | Suzhou | Jiangsu | Contract manufacturer | 3 |
Record
| Listed by | Remington Medical, Inc., United States |
|---|---|
| FDA product code | KNW |
| Device type | Instrument, Biopsy |
| Device class | Class 2 |
| Regulation | 21 CFR 876.1075 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K982401 |
| Record published | 2016-09-21 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Inner carton of 10, shipping carton of 10 |
| Sizes | Needle gauge 14 to 18 G |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| NAC-1816 | Needle Gauge 18 G | In distribution |
| NAC-1825MLL | Needle Gauge 18 G | In distribution |
| NAC-1816B | Needle Gauge 18 G | In distribution |
| NAC-1816BB | Needle Gauge 18 G | In distribution |
| NAC-1820 | Needle Gauge 18 G | In distribution |
| NAC-1825U | Needle Gauge 18 G | In distribution |
| NAC-1410MLL | Needle Gauge 14 G | In distribution |
| NAC-1825 ULTRA | Needle Gauge 18 G | In distribution |
| NAC-1825BB | Needle Gauge 18 G | In distribution |
| NAC-1820BB | Needle Gauge 18 G | In distribution |
| NAC-1825M | Needle Gauge 18 G | In distribution |
| NAC-1816M | Needle Gauge 18 G | In distribution |
| NAC-1820MLL | Needle Gauge 18 G | In distribution |
| NAC-1820 ULTRA | Needle Gauge 18 G | In distribution |
| NAC-1825B | Needle Gauge 18 G | In distribution |
| NAC-1820B | Needle Gauge 18 G | In distribution |
| NAC-1820M | Needle Gauge 18 G | In distribution |
| NAC-1410 | Needle Gauge 14 G | In distribution |
| NAC-1820U | Needle Gauge 18 G | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Curaway | Zhejiang Curaway Medical Technology Co., Ltd. | 910 |
| SureAim Coaxial Biopsy Needle | Canyon Medical Inc. | 157 |
| CorVocet™ | Merit Medical Systems, Inc. | 157 |
| SureCore Automatic Disposable Biopsy Needle | Canyon Medical Inc. | 156 |
| M Biopsy Automatic Disposable Biopsy Needle | Canyon Medical Inc. | 108 |
| M Biopsy Coaxial Biopsy Needle | Canyon Medical Inc. | 89 |
| Co-Axial Introducer Needle | Argon Medical Devices, Inc. | 80 |
| SureCore Semi-automatic Disposable Biopsy Needle | Canyon Medical Inc. | 76 |
| Invivo | Philips DS North America LLC | 71 |
| Coaxial needle | Möller Medical GmbH | 68 |
| Disposable needle for reusable biopsy gun | Möller Medical GmbH | 62 |
| Remington Medical, Inc. Automatic Cutting Needle (NAC) | Remington Medical, Inc. | 60 |
Showing 12 of 692. All products under Instrument, Biopsy
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K191315 | 2019-07-12 |
| K130282 | 2013-05-13 |
| K040266 | 2004-07-09 |
| K982401 | 1998-09-08 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Remington Medical, Inc. | UDI-DI | 2022-12-02 | Class II | Under Investigation by firm | The stylet is longer than specified on the label | 290 devices | 2026-03-16 |
| Remington Medical, Inc. | 510(k) number | 2012-08-29 | Class II | Material/Component Contamination | Sterility of the product may be compromised. | 800 needles | 2013-01-15 |
| Remington Medical, Inc. | 510(k) number | 2007-01-19 | Not classified | Other | Pouches were not sealed prior to sterilization. | 192 units | 2007-05-11 |
| Remington Medical, Inc. | 510(k) number | 2005-02-15 | Not classified | Other | The stylet hub detaches from the stylet needle. | 1737 units | 2005-05-17 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2011-02-07 | Not classified | Device Design | There is a potential for the needle hubs to break during use. | 10101 units | 2011-08-12 |
| 2011-02-07 | Not classified | Device Design | There is a potential for the needle hubs to break during use. | 8161 units | 2011-08-12 |
| 2011-02-07 | Not classified | Device Design | There is a potential for the needle hubs to break during use. | 4867 units | 2011-08-12 |
| 2011-02-07 | Not classified | Device Design | There is a potential for the needle hubs to break during use. | 23022 units | 2011-08-12 |
| 2011-02-07 | Not classified | Device Design | There is a potential for the needle hubs to break during use. | 727 units | 2011-08-12 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.