Bard® InLay Optima® Ureteral Stent

Inlay Optima Ureteral Stent W/O Guidewire

Registry build 21.09.26
4manufacturers in China registered for this device type
28catalogue numbers in this listing
7510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Zhejiang (1), Guangdong (1).

Chinese manufacturers registered for FDA product code FAD
Manufacturer City Province Registered as Device types
Zhejiang Chuangxiang Medical Technology Co., Ltd. Hangzhou Zhejiang Contract manufacturer 27
Alton Shanghai Medical Instruments Co Ltd Shanghai Shanghai Complaint-file establishment 20
BQ Plus Medical Co., Ltd. Songjiang Shanghai Contract manufacturer 13
Shenzhen Trious Medical Technology Co., Ltd. Shenzhen Guangdong Manufacturer 6

Record

Regulatory record for Bard® InLay Optima® Ureteral Stent
Listed by C.R. Bard, Inc., United States
FDA product code FAD
Device type Stent, Ureteral
Device class Class 2
Regulation 21 CFR 876.4620
Establishment Contract manufacturer, Contract steriliser, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2015-05-29
Record revised 2018-03-29 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Sizes Catheter gauge 4.7 to 8 Fr; length 14 to 30 cm

Catalogue Numbers

Catalogue numbers for Bard® InLay Optima® Ureteral Stent
Catalogue number Size Status
788626 Catheter Gauge 6 Fr In distribution
788720 Catheter Gauge 7 Fr In distribution
788722 Catheter Gauge 7 Fr In distribution
788620 Catheter Gauge 6 Fr In distribution
788724 Length 24 cm In distribution
788828 Catheter Gauge 8 Fr In distribution
788420 Catheter Gauge 4.7 Fr In distribution
788630 Catheter Gauge 6 Fr In distribution
788428 Catheter Gauge 4.7 Fr In distribution
788728 Catheter Gauge 7 Fr In distribution
788822 Catheter Gauge 8 Fr In distribution
788814 Length 14 cm In distribution
788820 Catheter Gauge 8 Fr In distribution
788628 Length 28 cm In distribution
788714 Length 14 cm In distribution
788830 Catheter Gauge 8 Fr In distribution
788622 Length 22 cm In distribution
788426 Catheter Gauge 4.7 Fr In distribution
788624 Catheter Gauge 6 Fr In distribution
788824 Length 24 cm In distribution
788730 Length 30 cm In distribution
788422 Catheter Gauge 4.7 Fr In distribution
788826 Catheter Gauge 8 Fr In distribution
788424 Length 24 cm In distribution
788614 Catheter Gauge 6 Fr In distribution
788726 Catheter Gauge 7 Fr In distribution
788430 Catheter Gauge 4.7 Fr In distribution
788414 Length 14 cm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Porges Coloplast Coloplast A/S 509
Polaris™ Ultra Boston Scientific Corporation 406
Universa Cook Incorporated 384
Percuflex™ Plus Boston Scientific Corporation 300
Polaris™ Loop Boston Scientific Corporation 232
ImaJin Coloplast A/S 219
Contour™ Boston Scientific Corporation 205
Percuflex™ Boston Scientific Corporation 152
Tecoflex Gyrus Acmi, Inc. 92
Vortek Coloplast A/S 92
Sof-Flex Cook Incorporated 60
Tria™ Firm Boston Scientific Corporation 58

Showing 12 of 131. All products under Stent, Ureteral

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K043193 2004-12-07
K022447 2003-01-23
K983498 1998-12-15
K903345 1991-04-30
K883561 1988-11-15
K861478 1986-05-15
K823487 1983-05-27

Recalls Naming This Product

3 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Bard® InLay Optima® Ureteral Stent
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
C.R. Bard, Inc. UDI-DI 2025-11-06 Class II Under Investigation by firm Labeling discrepancy; Ureteral stent actual size may not match the actual product label. 4350 units
C.R. Bard, Inc. UDI-DI 2025-11-06 Class II Under Investigation by firm Labeling discrepancy; Ureteral stent actual size may not match the actual product label. 116 units
C.R. Bard, Inc. UDI-DI 2025-11-06 Class II Under Investigation by firm Labeling discrepancy; Ureteral stent actual size may not match the actual product label. 116 units

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-11-06 Class II Under Investigation by firm Labeling discrepancy; Ureteral stent actual size may not match the actual product label. 116 units
2016-10-13 Class II Labeling Change Control Labeling: Statement was added to the Warnings/Precautions section requesting end users to consider the presence of a knot if significant resistance is encountered during attempts at removal. 75,089 units 2022-02-10
2016-10-13 Class II Labeling Change Control Labeling: Statement was added to the Warnings/Precautions section requesting end users to consider the presence of a knot if significant resistance is encountered during attempts at removal. 75,089 units 2022-02-10
2016-10-13 Class II Labeling Change Control Labeling: Statement was added to the Warnings/Precautions section requesting end users to consider the presence of a knot if significant resistance is encountered during attempts at removal. 75,089 units 2022-02-10
2016-10-13 Class II Labeling Change Control Labeling: Statement was added to the Warnings/Precautions section requesting end users to consider the presence of a knot if significant resistance is encountered during attempts at removal. 75,089 units 2022-02-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer