AMSure ® Foley Catheters Tray
400mL. Urine Meter attached to 2600mL drainage bag Hydrophilic Latex Foley Catheter 5 cc Balloon 16 Fr.
11manufacturers in China registered for this device type
9catalogue numbers in this listing
3510(k) clearances naming this product code
Who Else Makes It
Concentrated in Jiangsu (6), Zhejiang (5). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Conod Medical Co., Limited | Changshu | Jiangsu | Contract manufacturer | 48 |
| Shaoxing Jiancheng Medical Products Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 9 |
| Integral Medical Products Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 7 |
| Shaoxing Fuqing Health Products Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 3 |
| Changshu Rozer Sterilization Technology Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 43 |
| Joykey Industrial (Pinghu) Limited | Pinghu | Zhejiang | Contract manufacturer | 43 |
| Rozer Sterilization Technology Shuyang Company Limited | Shuyang | Jiangsu | Contract manufacturer | 33 |
| Nanjing Anjian Medical Device Co., Ltd. | Nanjing | Jiangsu | Contract manufacturer | 22 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Integral Sterilization Technology (Shaoxing) Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 5 |
Record
| Listed by | Amsino Medical Inc., United States |
|---|---|
| FDA product code | FCM |
| Device type | Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit) |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5130 |
| Establishment | Repacker / relabeller |
| Record published | 2022-04-04 |
| Record revised | 2022-09-26 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Contains natural rubber latex |
| Label carries | lot or batch number, expiry date |
| Packaging | Case of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1 | In distribution | |
| 1 | In distribution | |
| 1 | In distribution | |
| 1 | In distribution | |
| 1 | In distribution | |
| 1 | In distribution | |
| 1 | In distribution | |
| 1 | In distribution | |
| 1 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Dover | Cardinal Health | 72 |
| Dover | Cardinal Health 200, LLC | 55 |
| Gentlecath | Convatec, Purchasing Department | 28 |
| AMSure® Foley Catheter Tray | Amsino Medical Inc. | 26 |
| Medline Industries, Inc. | Medline Industries, Inc. | 20 |
| Self-Cath Closed System | Coloplast A/S | 20 |
| Cure Catheter® Closed System | Convatec, Purchasing Department | 17 |
| Nurse Assist | Nurse Assist, LLC | 17 |
| Bard® Touchless® Plus Unisex Pre-Lubricated Vinyl Urethral Catheter | C.R. Bard, Inc. | 13 |
| Apogee Plus | Hollister Incorporated | 12 |
| Advance Plus | Hollister Incorporated | 9 |
| Medline | Medline Industries, Inc. | 8 |
Showing 12 of 45. All products under Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K082831 | 2008-10-23 |
| K030712 | 2003-05-23 |
| K030664 | 2003-05-23 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.