Gentlecath
CVT Gentlecath IC Cath Insert Supplies KIT
Who Else Makes It
Concentrated in Jiangsu (6), Zhejiang (5). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Conod Medical Co., Limited | Changshu | Jiangsu | Contract manufacturer | 48 |
| Shaoxing Jiancheng Medical Products Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 9 |
| Integral Medical Products Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 7 |
| Shaoxing Fuqing Health Products Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 3 |
| Changshu Rozer Sterilization Technology Co., Ltd. | Changshu | Jiangsu | Contract manufacturer | 43 |
| Joykey Industrial (Pinghu) Limited | Pinghu | Zhejiang | Contract manufacturer | 43 |
| Rozer Sterilization Technology Shuyang Company Limited | Shuyang | Jiangsu | Contract manufacturer | 33 |
| Nanjing Anjian Medical Device Co., Ltd. | Nanjing | Jiangsu | Contract manufacturer | 22 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Integral Sterilization Technology (Shaoxing) Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 5 |
Record
| Listed by | Convatec, Purchasing Department |
|---|---|
| FDA product code | FCM |
| Device type | Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit) |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5130 |
| 510(k) | K010420 |
| Record published | 2016-09-09 |
| Record revised | 2022-05-23 (version 10) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Case of 100, pack of 100 |
| Distribution end date | 2022-05-20 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 421428 | 08 FR | Withdrawn |
| 421414 | 12 FR | Withdrawn |
| 421415 | 14 FR | Withdrawn |
| 421430 | 12 FR | Withdrawn |
| 421421 | 14 FR | Withdrawn |
| 421439 | 14 FR | Withdrawn |
| 421423 | 12 FR | Withdrawn |
| 421417 | 18 FR | Withdrawn |
| 421425 | 16 FR | Withdrawn |
| 421432 | 16 FR | Withdrawn |
| 421436 | 14 FR | Withdrawn |
| 421412 | 08 FR | Withdrawn |
| 421416 | 16 FR | Withdrawn |
| 421422 | 16 FR | Withdrawn |
| 421427 | 14 FR | Withdrawn |
| 421431 | 14 FR | Withdrawn |
| 421426 | 14 FR | Withdrawn |
| 421411 | 06 FR | Withdrawn |
| 421429 | 10 FR | Withdrawn |
| 421434 | 14 FR | Withdrawn |
| 421420 | 12 FR | Withdrawn |
| 503870 | Withdrawn | |
| 421437 | 16 FR | Withdrawn |
| 421413 | 10 FR | Withdrawn |
| 421433 | 12 FR | Withdrawn |
| 421418 | 12 FR | Withdrawn |
| 421424 | 14 FR | Withdrawn |
| 421419 | 14 FR | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Dover | Cardinal Health | 72 |
| Dover | Cardinal Health 200, LLC | 55 |
| AMSure® Foley Catheter Tray | Amsino Medical Inc. | 26 |
| Medline Industries, Inc. | Medline Industries, Inc. | 20 |
| Self-Cath Closed System | Coloplast A/S | 20 |
| Cure Catheter® Closed System | Convatec, Purchasing Department | 17 |
| Nurse Assist | Nurse Assist, LLC | 17 |
| Bard® Touchless® Plus Unisex Pre-Lubricated Vinyl Urethral Catheter | C.R. Bard, Inc. | 13 |
| Apogee Plus | Hollister Incorporated | 12 |
| Advance Plus | Hollister Incorporated | 9 |
| AMSure ® Foley Catheters Tray | Amsino Medical Inc. | 9 |
| Medline | Medline Industries, Inc. | 8 |
Showing 12 of 45. All products under Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Teleflex Medical LLC | 510(k) number | 2022-09-20 | Class II | Nonconforming Material/Component | Product may not be sterile | 7200 catheters | |
| Teleflex Medical LLC | 510(k) number | 2016-11-22 | Class II | Error in labeling | Labeling Inconsistency: The products have been labeled with the incorrect expiration date which exceeds the actual, validated 35-month shelf life. | 102,843 units | 2017-11-24 |
| Teleflex Medical LLC | 510(k) number | 2005-07-11 | Not classified | Other | There is a lack of assurance of sterility for parts of these lots of product. | 95,800 units | 2007-11-14 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.