Blood Circuit SET
Single Needle Expansion Chamber
5manufacturers in China registered for this device type
1catalogue number
1510(k) clearance
11recalls on this code
Who Else Makes It
Concentrated in Guangdong (3), Zhejiang (1), Jiangxi (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Ningbo Tianyi Medical Appliance Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 11 |
| Guangzhou Kaiheng K&S Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 9 |
| Jiangxi Sanxin Medtec Co., Ltd. | Nanchang | Jiangxi | Manufacturer | 6 |
| Bain Medical Equipment(Guangzhou) Co., Ltd. | Guangzhou | Guangdong | Manufacturer | 3 |
| Vital Healthcare (Guangzhou) Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 3 |
Record
| Listed by | Baxter Healthcare Corporation, United States |
|---|---|
| FDA product code | FJK |
| Device type | Set, Tubing, Blood, With And Without Anti-Regurgitation Valve |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5820 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K201809 |
| Record published | 2021-05-13 |
| Record revised | 2023-07-27 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Storage environment temperature 0 to 30 °C |
| Packaging | Case of 32 |
| Sizes | Weight 110 g |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 101739 | Weight 110 g | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| ICU Medical | ICU Medical, Inc | 58 |
| Nipro SET Blood Tubing SET With Transducer Protectors AND Priming SET | Nipro Medical Corporation | 12 |
| Hemodialysis Bloodlines | B. Braun Medical Inc. | 12 |
| CombiSet | Fresenius Medical Care | 11 |
| Cartridge Blood Set | Gambro Renal Products S.A. DE C.V. | 8 |
| 5008X | Fresenius Medical Care Renal Therapies Group, LLC | 7 |
| Sunder | Sunder Biomedical Tech. Co., Ltd. | 6 |
| Streamline Airless System Set with Locksite Needleless Access Sites | Medisystems Corp. | 5 |
| Tablo(R) Cartridge | Outset Medical, Inc. | 5 |
| NovaLine | Bain Medical Equipment(Guangzhou) Co., Ltd. | 5 |
| Medisystems Hemodialysis Blood Tubing Sets | Medisystems Corp. | 4 |
| Diapact® | B. Braun Medical Inc. | 4 |
Showing 12 of 44. All products under Set, Tubing, Blood, With And Without Anti-Regurgitation Valve
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K934803 | 1993-12-17 |
Recalls
11 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2021-04-14 | Class II | Under Investigation by firm | There is a potential leak between the venous patient connector and patient’s hemodialysis access. | 17,487 units | 2024-05-10 |
| 2020-12-30 | Class II | Under Investigation by firm | complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. | 1460 devices | |
| 2020-12-30 | Class II | Under Investigation by firm | complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. | 385 devices | |
| 2020-12-30 | Class II | Under Investigation by firm | complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. | 211155 devices | |
| 2020-12-30 | Class II | Under Investigation by firm | complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. | 7437480 units | |
| 2020-12-30 | Class II | Under Investigation by firm | complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. | 25785 devices | |
| 2020-12-30 | Class II | Under Investigation by firm | complaints of kinked access lines observed during treatment using cartridge sets for hemodialysis treatments were received. | 57825 devices | |
| 2020-04-17 | Class II | Process control | Potential disconnection of tubing set. | 4,065 | 2023-02-07 |
| 2020-04-17 | Class II | Process control | Potential disconnection of tubing set. | 53,895 units | 2023-02-07 |
| 2020-04-17 | Class II | Process control | Potential disconnection of tubing set. | 2,361,885 units | 2023-02-07 |
| 2020-04-17 | Class II | Process control | Potential disconnection of tubing set. | 19,800 units | 2023-02-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.