Slimline™ Blood Tubing SET With Transducer Protectors AND Priming SET
PUMP SEGMENT 8.0 mm PRIMING VOLUME 119 ML EQUIPMENT FRESENIUS 2008H, K, K2, T
Who Else Makes It
Concentrated in Guangdong (3), Zhejiang (1), Jiangxi (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Ningbo Tianyi Medical Appliance Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 11 |
| Guangzhou Kaiheng K&S Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 9 |
| Jiangxi Sanxin Medtec Co., Ltd. | Nanchang | Jiangxi | Manufacturer | 6 |
| Bain Medical Equipment(Guangzhou) Co., Ltd. | Guangzhou | Guangdong | Manufacturer | 3 |
| Vital Healthcare (Guangzhou) Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 3 |
Record
| Listed by | Nipro Medical Corporation, United States |
|---|---|
| FDA product code | FJK |
| Device type | Set, Tubing, Blood, With And Without Anti-Regurgitation Valve |
| Device class | Class 2 |
| Regulation | 21 CFR 876.5820 |
| Establishment | Complaint-file establishment, Exporter |
| Record published | 2015-09-16 |
| Record revised | 2019-06-07 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Case of 28 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| A226Y/V813 | In distribution | |
| BL+A226Y/V813-NIJ | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| ICU Medical | ICU Medical, Inc | 58 |
| Nipro SET Blood Tubing SET With Transducer Protectors AND Priming SET | Nipro Medical Corporation | 12 |
| Hemodialysis Bloodlines | B. Braun Medical Inc. | 12 |
| CombiSet | Fresenius Medical Care | 11 |
| Cartridge Blood Set | Gambro Renal Products S.A. DE C.V. | 8 |
| 5008X | Fresenius Medical Care Renal Therapies Group, LLC | 7 |
| Sunder | Sunder Biomedical Tech. Co., Ltd. | 6 |
| Streamline Airless System Set with Locksite Needleless Access Sites | Medisystems Corp. | 5 |
| Tablo(R) Cartridge | Outset Medical, Inc. | 5 |
| NovaLine | Bain Medical Equipment(Guangzhou) Co., Ltd. | 5 |
| Medisystems Hemodialysis Blood Tubing Sets | Medisystems Corp. | 4 |
| Diapact® | B. Braun Medical Inc. | 4 |
Showing 12 of 44. All products under Set, Tubing, Blood, With And Without Anti-Regurgitation Valve
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K112628 | 2012-09-28 |
| K072024 | 2007-10-04 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-12-19 | Class II | Process control | There is a possibility of the heparin line is occluded. | 307,944 units. | 2021-10-19 |
| 2015-03-30 | Class II | Device Design | Blood foaming was found during evaluation of the product. | 1,484 pieces. | 2016-02-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.