Primus Sterlizer

The PRIMUS PSS11-HC sterilizer uses pressurized steam to process heat and moisture stable medical materials in surgical and central sterile departments. Its validated uses include porous…

Registry build 21.09.26

The PRIMUS PSS11-HC sterilizer uses pressurized steam to process heat and moisture stable medical materials in surgical and central sterile departments. Its validated uses include porous and nonporous loads. Materials must withstand the selected cycle’s operating temperature and moisture conditions.

A stainless steel chamber and surrounding jacket form the sterilizer vessel. Steam enters the chamber through a baffled inlet, while the drainage system removes condensate. A vacuum system reduces chamber pressure during conditioning and drying, and filtered air restores atmospheric pressure after the drying phase.

Listed Item

PRIMUS Healthcare Sterilizer (Model PSS11-HC)

Cycle Control

A touchscreen provides access to programmed processing cycles and operating controls. The integrated thermal printer records cycle data at the start, at transitions and at completion, providing a paper record of the run. Cycle and load selection must follow the validated configurations.

3manufacturers in China registered for this device type
1catalogue number
6510(k) clearances naming this product code

Who Else Makes It

Concentrated in Shanghai (1), Guangdong (1), Zhejiang (1).

Chinese manufacturers registered for FDA product code FLE
Manufacturer City Province Registered as Device types
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Guangzhou Ajax Medical Equipment Co Ltd Guangzhou Guangdong Manufacturer 13
Ningbo Ican Machines Co., Ltd. Ningbo Zhejiang Manufacturer 1

Record

Regulatory record for Primus Sterlizer
Listed by Primus Sterilizer Company, LLC., United States
FDA product code FLE
Device type Sterilizer, Steam
Device class Class 2
Regulation 21 CFR 880.6880
Establishment Manufacturer
510(k) K221474
Record published 2023-12-14

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Over the counter Yes
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Primus Sterlizer
Catalogue number Size Status
PSS11-HC In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Amsco Steris Mexico, S. de R.L. de C.V. 434
Getinge 500 Series Getinge IC Production Poland sp. z o.o. 133
Getinge 700 Series Getinge IC Production Poland sp. z o.o. 82
Aesculap Aesculap AG 67
Getinge 600 Series Getinge IC Production Poland sp. z o.o. 61
Sterilizer, Steam Steris Mexico, S. de R.L. de C.V. 53
Getinge 800 Series Getinge IC Production Poland sp. z o.o. 41
Getinge 400 Series Getinge IC Production Poland sp. z o.o. 37
Primus Sterilizer Primus Sterilizer Company, LLC. 24
Midmark Midmark Corporation 21
Bravo 17V Autoclave Scican Ltd. 19
Atlas Steris Mexico, S. de R.L. de C.V. 18

Showing 12 of 119. All products under Sterilizer, Steam

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K233132 2023-12-19
K221474 2023-02-10
K093333 2010-04-02
K082817 2009-05-21
K991575 1999-12-03
K926185 1994-05-09

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer