Sterilizer, Steam

The P2131-2 Water Recovery System (WRS) is the water recycling and vacuum source component of the P2131 Automated Field Sterilizer system. The WRS reclaims hot condensate and exhaust steam…

Registry build 21.09.26

The P2131-2 Water Recovery System (WRS) is the water recycling and vacuum source component of the P2131 Automated Field Sterilizer system. The WRS reclaims hot condensate and exhaust steam for re-use by the sterilizer. The WRS also includes a water eductor, which provides the vacuum capability for the pre and post-vacuum phases of sterilization. The P2131 is an automated, pre- and post-vacuum steam sterilizer designed for sterilization of porous and non-porous, heat- and moisture-stable materials (e.g., surgical instruments and textiles) used in healthcare facilities. The P2131 sterilizer is a transportable device designed for field use in a variety of austere environments. The P2131 sterilizer consists of three components that work together as one integrated system. These components are the (1) Sterilizer Main Unit (SMU), (2) Water Recovery System (WRS), and (3) the Sterilizer Water Softener (SWS).

3manufacturers in China registered for this device type
6catalogue numbers in this listing
3510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Shanghai (1), Guangdong (1), Zhejiang (1).

Chinese manufacturers registered for FDA product code FLE
Manufacturer City Province Registered as Device types
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Guangzhou Ajax Medical Equipment Co Ltd Guangzhou Guangdong Manufacturer 13
Ningbo Ican Machines Co., Ltd. Ningbo Zhejiang Manufacturer 1

Record

Regulatory record for Sterilizer, Steam
Listed by Fort Defiance Industries LLC, United States
FDA product code FLE
Device type Sterilizer, Steam
Device class Class 2
Regulation 21 CFR 880.6880
Establishment Complaint-file establishment, Manufacturer
510(k) K141009
Record published 2016-09-20
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries serial number
Sizes Weight 50 to 532 lb; height 21.625 to 62 in; width 13 to 39.75 in; length 20 to 38 in

Catalogue Numbers

Catalogue numbers for Sterilizer, Steam
Catalogue number Size Status
P2131-3 Weight 50 lb In distribution
P2131-2 Weight 170 lb In distribution
P2131-1 Weight 295 lb In distribution
P2131 Weight 532 lb In distribution
FRONT-LINE FL120 Length 31.3125 in In distribution
FRONT-LINE FL135 Length 31.875 in In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Amsco Steris Mexico, S. de R.L. de C.V. 434
Getinge 500 Series Getinge IC Production Poland sp. z o.o. 133
Getinge 700 Series Getinge IC Production Poland sp. z o.o. 82
Aesculap Aesculap AG 67
Getinge 600 Series Getinge IC Production Poland sp. z o.o. 61
Sterilizer, Steam Steris Mexico, S. de R.L. de C.V. 53
Getinge 800 Series Getinge IC Production Poland sp. z o.o. 41
Getinge 400 Series Getinge IC Production Poland sp. z o.o. 37
Primus Sterilizer Primus Sterilizer Company, LLC. 24
Midmark Midmark Corporation 21
Bravo 17V Autoclave Scican Ltd. 19
Atlas Steris Mexico, S. de R.L. de C.V. 18

Showing 12 of 119. All products under Sterilizer, Steam

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K243801 2025-03-07
K213457 2022-03-02
K141009 2014-12-16

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Sterilizer, Steam
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Fort Defiance Industries LLC 510(k) number 2026-07-08 Class II Component design/selection The Automated Field Steam Sterilizer’s water recovery system 120V Amphenol connector may experience an intermittent loss of ground continuity, which could result in an unreliable fault current return path.
Fort Defiance Industries LLC 510(k) number 2021-08-19 Class II Device Design The rear heater plate and cover assembly that contains the electrical wiring for the heaters does not have sufficient bonding to ground. 380 devices
Fort Defiance Industries LLC 510(k) number 2018-05-24 Class II Device Design During long-term storage (i.e. military depot), the interaction of stagnant water and dissimilar metals in the plumbing of the P2131 device produces deposits in the water system that can potentially interfere with the rear sight gauge and / 199 units 2023-06-27

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer