PremierPro Air Transfer Mat
INTENDED USE/ CONTRAINDICATIONS PremierPro™ Air Transfer Mats are indicated for patients: Who are unable to transfer or turn by their own effort, both assisted and unassisted. Whose size…
INTENDED USE/ CONTRAINDICATIONS PremierPro™ Air Transfer Mats are indicated for patients: Who are unable to transfer or turn by their own effort, both assisted and unassisted. Whose size and weight present possible risks to caregivers involved in the transfer of the patient. PRECAUTIONS & WARNINGS Use two or more caregivers during patient transfers. Do not use transfer mat until user manual is reviewed. Do not leave patient unattended on inflated transfer mat. Do not attempt to move patient on uninflated transfer mat. The maximum safe working load for all PremierPro™ Air Transfer Mats is l,000lbs (450kg). AIR SUPPLY Air supply units may be compatible with Premier™ Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75″ diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating instructions, observing all precautions and warnings. All safety guidelines within the air supply unit’s operating instructions should be followed. MRI SAFETY PremierPro™ Air Transfer Mats may be used in situations that require transferring patients undergoing Magnetic Resonance Imaging (MRI). PremierPro™ Air Transfer Mats have been evaluated for use with MRI and have been determined to be safe for use. This conclusion is based on the following factors: Materials of construction for top and bottom fabrics include Nylon, PVC and Mesh. Safety strap buckles are constructed from Polypropylene. Air supply fasteners are manufactured from non-ferrous metal. Air supply fasteners are not in the radio frequency field or the field of imaging and will not cause artifacts. Evaluation of these factors indicates PremierPro™ Air Transfer Mats are safe when used with patients undergoing MRI. CLEANING The PremierPro™ Disposable Air Transfer Mat is not intended to be laundered and reused. Check Local, State and Federal Guidelines before disposing of this product.
Who Else Makes It
Concentrated in Guangdong (13), Jiangsu (5), Zhejiang (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Kunshan Hi-Fortune Health Products Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 32 |
| Hubei Yinkang Medical Equipment Co., Ltd. | Xiaogan | Hubei | Contract manufacturer | 8 |
| Gcmedica Enterprise Ltd.(Wuxi) | Wuxi | Jiangsu | Contract manufacturer | 55 |
| Dragon Medical Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 48 |
| Yearstar Healthcare Technology Co., Ltd. | Jiangyin | Jiangsu | Contract manufacturer | 43 |
| Foshan Fuzikon Medical Technology Co., Ltd. | Foshan | Guangdong | Manufacturer | 21 |
| Zhejiang Mateside Medical Devices Technology Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 21 |
| Hebei Jiede Medical Equipment Co., Ltd. | Hengshui | Hebei | Contract manufacturer | 20 |
| Shenzhen Zhouyang Medical Care Product Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 18 |
| Metacare Industrial Ltd | Guangzhou | Guangdong | Contract manufacturer | 17 |
| Foshan Dahao Medical Technology Co., Ltd. | Foshan | Guangdong | Manufacturer | 13 |
| Zhongshan Juncheng Medical Technology Co., Ltd. | Zhongshan | Guangdong | Manufacturer | 12 |
Showing 12 of 27. All 27 manufacturers in China registered for Device, Patient Transfer, Powered
Record
| Listed by | Prestige Ameritech, United States |
|---|---|
| FDA product code | FRZ |
| Device type | Device, Patient Transfer, Powered |
| Device class | Class 2 |
| Regulation | 21 CFR 880.6775 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2018-04-10 |
| Record revised | 2026-03-23 (version 3) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Single use | Yes |
| Latex | Labelled latex-free |
| Packaging | Pack of 10 |
| Sizes | Length 34 to 39 in |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 3710 | Length 34 in | In distribution |
| 3711 | Length 39 in | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Zephyr Patient Positioning and Transfer System | Diacor, Inc. | 83 |
| Single Patient Use HoverMatt | Hovertech International | 38 |
| Sustainable Technologies | Cardinal Health 200, LLC | 21 |
| Hovertech | Hygia Health Services, Inc. | 19 |
| Device, Patient Transfer, Powered | Stryker Sustainability Solutions | 18 |
| HoverMatt | Hovertech International | 11 |
| PremierPro Air Transfer Mats | Prestige Ameritech | 10 |
| Medline | Medline Industries, Inc. | 10 |
| Airpal | Caremed Supply, Inc. | 9 |
| HoverSling | Hovertech International | 6 |
| HoverTech Air Supply | Hovertech International | 6 |
| PPS Glide | Patient Positioning Systems, LLC | 6 |
Showing 12 of 46. All products under Device, Patient Transfer, Powered
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.