System 1e Liquid Chemical Sterilant Processing System – Reworked Placement Progr
The SYSTEM 1E Liquid Chemical Sterilant Processing System is for safe and effective reprocessing of heat-sensitive critical and semi-critical medical devices. This unit is distributed…
The SYSTEM 1E Liquid Chemical Sterilant Processing System is for safe and effective reprocessing of heat-sensitive critical and semi-critical medical devices. This unit is distributed through the STERIS Reworked Placement Program.
Who Else Makes It
Registered in Zhejiang. One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Saint-Gobain Life Sciences (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 5 |
Record
| Listed by | Corporation Steris Canada |
|---|---|
| FDA product code | MED |
| Device type | Sterilant, Medical Devices |
| Device class | Class 2 |
| Regulation | 21 CFR 880.6885 |
| 510(k) | K090036 |
| Record published | 2016-09-13 |
| Record revised | 2026-04-27 (version 10) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Over the counter | Yes |
| Label carries | manufacturing date, serial number |
| Distribution end date | 2021-06-14 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1E | In distribution | |
| 1E | In distribution | |
| 1E | Withdrawn | |
| 1E | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Sterilant, Medical Devices | Steris Corporation | 149 |
| Formed Irrigating Cystotomes | Sterimedix Ltd. | 37 |
| Hydrodissection Cannulae | Sterimedix Ltd. | 29 |
| Sterilant, Medical Devices | Corporation Steris Canada | 29 |
| Anterior Chamber Maintenance Cannulae | Sterimedix Ltd. | 17 |
| Anaesthetic Needles | Sterimedix Ltd. | 14 |
| Formed Capsularhexis Cystotomes | Sterimedix Ltd. | 8 |
| Refractive Cannulae | Sterimedix Ltd. | 8 |
| enspire | Corporation Steris Canada | 8 |
| Cidex™ | Advanced Sterilization Products Services Inc. | 8 |
| Bimanual Cannulae and Hand Pieces | Sterimedix Ltd. | 7 |
| Bimanual I/A Systems | Sterimedix Ltd. | 7 |
Showing 12 of 96. All products under Sterilant, Medical Devices
Recalls Naming This Product
6 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Steris Corporation | 510(k) number | 2015-12-04 | Class II | Nonconforming Material/Component | The firm discovered that one of the hysteroscope models listed for processing in four existing Quick Connects has one inlet port rather than two inlet ports as indicated in the Quick Connect processing instructions. | 809 units | 2016-08-26 |
| Steris Corporation | 510(k) number | 2013-03-04 | Class II | Labeling Change Control | During a routine label review, the firm identified four SYSTEM 1E Quick Connects that will be updated to reflect the removal of obsolete device models. This labeling review process also highlighted the opportunity to combine two existing q | QLC1677E: 38; QRC1699E: 128 & QPC1721E/QFC1683E: 0 | 2013-07-02 |
| Steris Corporation | 510(k) number | 2012-08-10 | Class II | Device Design | STERIS has been actively seeking devices for quick connect revalidation projects. STERIS was unable to obtain two (2) of the needed devices; these two devices represent the design of seven (7) models in one quick connect. Due to the unava | 64 units | 2013-07-05 |
| Steris Corporation | 510(k) number | 2012-08-01 | Class II | Nonconforming Material/Component | The firm initiated a recall after complaint investigations revealed that when the units are left on and not in use at night and/or on weekends the hose disconnects/separates resulting in water leakage that can cause damage to property. | 6,051 units | 2014-06-06 |
| Steris Corporation | 510(k) number | 2011-12-07 | Not classified | Software design | Software deficiency. STERIS identified that water specifications were not being met at some of their customer sites. Critical parameters for initiating cycles are: water quality, water pressure and water temperature. Failure to meet thes | 3,882 units were distributed | 2014-05-13 |
| Steris Corporation | 510(k) number | 2011-03-14 | Not classified | Other | The printout, display and Operator Manual for the STERIS System 1E Liquid Chemical Sterilant Processing System are subject to recall/correction by the firm because in the event of an incomplete or aborted cycle, the language of the warnin | 106 units | 2013-03-13 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.