B.braun
Celsite STL201L ST SET SIL 8,5F L IV USA
Who Else Makes It
Concentrated in Guangdong (1), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Forefront Medical Technology (Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 14 |
Record
| Listed by | B. Braun Interventional Systems, Inc., United States |
|---|---|
| FDA product code | LJT |
| Device type | Port & Catheter, Implanted, Subcutaneous, Intravascular |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5965 |
| Record published | 2015-07-29 |
| Record revised | 2023-09-07 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Store at room temp; Special storage condition: Avoid extreme temperature; Special storage condition: Keep away from sunlight; Special storage condition: KEEP DRY |
| Sizes | Catheter gauge 8.5 Fr |
| Distribution end date | 2021-12-10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5430144 | Catheter Gauge 8.50 Fr | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Dignity® | Medical Components Inc | 168 |
| Deltec | ICU Medical, Inc | 130 |
| NorPort Vascular Access Port | Norfolk Medical | 106 |
| BioFlo Vortex | AngioDynamics, Inc. | 60 |
| BioFlo Vortex | Navilyst Medical, Inc. | 59 |
| Dignity® MID-Sized CT Port | Medical Components Inc | 55 |
| TidalPort Vascular Access Port | Norfolk Medical | 52 |
| Pro-Fuse® Low Profile CT Port | Medical Components Inc | 45 |
| Dignity® Low Profile CT Port | Medical Components Inc | 45 |
| Dignity® Mini CT Port | Medical Components Inc | 44 |
| Medcomp GEN III Power Injectable Portmedcomp GEN III Power Injectable Port | Medical Components Inc | 29 |
| PRO-Fuse® | Medical Components Inc | 28 |
Showing 12 of 96. All products under Port & Catheter, Implanted, Subcutaneous, Intravascular
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K130576 | 2013-04-02 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2015-06-16 | Class II | Unknown/Undetermined by firm | The manufacturer, B. Braun medical France, received endotoxin test results that are out of specification for the peelable sheath (A1537). | 11 units | 2015-11-20 |
| 2011-04-13 | Not classified | Process design | The affected products contain the incorrect winged Surecan needle accessory component in certain Celsite Access Port package configurations. The winged Surecan needle is used to deliver medications and fluids into implanted Celsite Access P | 83 | 2012-07-06 |
| 2009-06-22 | Not classified | Nonconforming Material/Component | B. Braun Interventional Systems was notified by B. Braun Medical France, the manufacturer of the Celsite Access port that they had received 11 reports of polyurethane (type P) catheter disconnections. B. Braun Medical France has decided to | 40 in US | 2012-06-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.