PowerPort ClearVUE

PowerPort ClearVUE Slim Implantable Port with Attachable 6F Polyurethane Open-Ended Single-Lumen Venous Catheter Microintroducer Kit

Registry build 21.09.26
2manufacturers in China registered for this device type
28catalogue numbers in this listing
6510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Guangdong (1), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LJT
Manufacturer City Province Registered as Device types
Turnxon Precision Co., Ltd. Dongguan Guangdong Contract manufacturer 17
Forefront Medical Technology (Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 14

Record

Regulatory record for PowerPort ClearVUE
Listed by Bard Access Systems, Inc., United States
FDA product code LJT
Device type Port & Catheter, Implanted, Subcutaneous, Intravascular
Device class Class 2
Regulation 21 CFR 880.5965
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2016-01-06
Record revised 2024-08-28 (version 7)

Specifications

Specifications
MRI safety MR Safe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Packaging Case of 5
Sizes Catheter gauge 6 to 8 Fr; length 45 cm

Catalogue Numbers

Catalogue numbers for PowerPort ClearVUE
Catalogue number Size Status
5678300 Catheter Gauge 8 Fr In distribution
1676301 Length 45 cm In distribution
CP00004 Catheter Gauge 8 Fr In distribution
1618001 Length 45 cm In distribution
1666362 Catheter Gauge 6 Fr In distribution
1668362 Catheter Gauge 8 Fr In distribution
1676300 Length 45 cm In distribution
1608062 Catheter Gauge 8 Fr In distribution
5676301 Length 45 cm In distribution
5616000 Catheter Gauge 6 Fr In distribution
1616070 Catheter Gauge 6 Fr In distribution
5676300 Length 45 cm In distribution
5618000 Catheter Gauge 8 Fr In distribution
1606052 Catheter Gauge 6 Fr In distribution
5678301 Length 45 cm In distribution
1678300 Catheter Gauge 8 Fr In distribution
1618000 Length 45 cm In distribution
1606062 Length 45 cm In distribution
5668362 Catheter Gauge 8 Fr In distribution
1616001 Catheter Gauge 6 Fr In distribution
CP00005 Length 45 cm In distribution
5608062 Length 45 cm In distribution
1608052 Length 45 cm In distribution
5666362 Catheter Gauge 6 Fr In distribution
1678301 Length 45 cm In distribution
1618070 Length 45 cm In distribution
1616000 Length 45 cm In distribution
1616071 Length 45 cm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Dignity® Medical Components Inc 168
Deltec ICU Medical, Inc 130
NorPort Vascular Access Port Norfolk Medical 106
BioFlo Vortex AngioDynamics, Inc. 60
BioFlo Vortex Navilyst Medical, Inc. 59
Dignity® MID-Sized CT Port Medical Components Inc 55
TidalPort Vascular Access Port Norfolk Medical 52
Pro-Fuse® Low Profile CT Port Medical Components Inc 45
Dignity® Low Profile CT Port Medical Components Inc 45
Dignity® Mini CT Port Medical Components Inc 44
Medcomp GEN III Power Injectable Portmedcomp GEN III Power Injectable Port Medical Components Inc 29
PRO-Fuse® Medical Components Inc 28

Showing 12 of 96. All products under Port & Catheter, Implanted, Subcutaneous, Intravascular

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252478 2025-09-05
K251253 2025-06-18
K242328 2024-10-31
K050310 2005-04-18
K926139 1995-01-03
K924250 1993-10-04

Recalls Naming This Product

15 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of PowerPort ClearVUE
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Bard Peripheral Vascular, Inc. UDI-DI 2020-01-15 Class II Employee error The catheter locks for the lot may contain an 8Fr catheter lock instead of a 6Fr catheter lock per device labeling. 200 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 359 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 2395 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 1551 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 216 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 2835 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 383 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 876 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 4044 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 3196 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 835 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 1411 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 181 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 15 units
Bard Peripheral Vascular, Inc. UDI-DI 2018-02-08 Class II Error in labeling The Patient ID Card packaged with the POWERPORT ClearVUE Implantable Port with Smooth Septum contains incorrect port flushing instructions. 10 units

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2014-08-08 Class II Nonconforming Material/Component Some unit packages of BD PosiFlush SF Saline Flush Syringe 10 mL may exhibit open seals, which could impact product sterility. Bard includes these pouched syringes, attached to some configurations of PICC kits, Port Access kits (PAK), Power 16,410 units 2015-08-05
2014-02-27 Class II Packaging Labeling discrepancy.The label states that the implantable port contains silicone suture plugs, however approximately 23% of the units contained in the affected lots have a PowerPort Slim titanium implantable port without silicone suture pl 777 2014-09-05
2012-02-16 Not classified Labeling Change Control The end flap label on the kit incorrectly describes the product as “Bard Port” MRI DUAL Implanted Port instead of a “Bard Port MRI Implanted Port” as correctly indicated on the main label of the kit. 545 units (Lot RESF0856 – 150 units; Lot RESH0067 – 295 unit 2012-03-30
2010-03-18 Not classified Mixed-up of materials/components 8F PowerPort stems were mixed with 6F PowerPorts and packaged. 200 units total (100 units of each lot, see code information 2010-10-01

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer