LifeShield Infusion Safety Software Suite – LifeShield CDR

LifeShield Clinical Dashboards & Reports is the reporting component of the LifeShield Infusion Safety Software Suite. It displays infusion and device information received from compatible…

Registry build 21.09.26

LifeShield Clinical Dashboards & Reports is the reporting component of the LifeShield Infusion Safety Software Suite. It displays infusion and device information received from compatible Plum Duo pumps through LifeShield Data Flow Management.

Clinical administrators can view ongoing infusion status, pump asset information and operational status. Dashboards summarize infusion or asset metrics, while an analytics viewer provides historical data. Information can cover one or several facilities within the customer account.

Listed Item

Infusion Safety Management Software

Data and Clinical Roles

The cloud-based suite manages connected pump data for trained healthcare professionals. CDR supports review, trending and quality-improvement analysis; its information does not generate patient treatment decisions or pathways. The suite also contains separate drug-library and device-management services. Infusion-parameter entry and validation remain with the trained healthcare professional.

1manufacturer
2catalogue numbers in this listing
3510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Registered in Shanghai. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code PHC
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31

Record

Regulatory record for LifeShield Infusion Safety Software Suite – LifeShield CDR
Listed by ICU Medical, Inc, United States
FDA product code PHC
Device type Infusion Safety Management Software
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K223606
Record published 2023-10-03

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for LifeShield Infusion Safety Software Suite – LifeShield CDR
Catalogue number Size Status
2.1 In distribution
2.1 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Ivenix Infusion System Fresenius Kabi AB 6
BD Intelliport Becton, Dickinson AND Company 5
PharmGuard ICU Medical, Inc 4
LifeShield Infusion Safety Software Suite ICU Medical, Inc 3
Dose IQ Safety Software Baxter Healthcare Corporation 3
Alaris CareFusion 303, Inc 3
ICU Medical MedNet ICU Medical, Inc 3
Alaris™ Guardrails™ Editor Software Kit, Model 8961 CareFusion 303, Inc 2
BD Alaris CareFusion 303, Inc 1
BD Alaris™ System Manager 9601, Software CareFusion 303, Inc 1
Vigilant Software Suite Fresenius Kabi AB 1
BD Intelliport System Becton, Dickinson AND Company 1

Showing 12 of 20. All products under Infusion Safety Management Software

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252130 2026-04-02
K242117 2025-04-02
K223606 2023-08-24

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of LifeShield Infusion Safety Software Suite – LifeShield CDR
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
ICU Medical, Inc 510(k) number 2025-05-02 Class II Software Design Change Firm has identified Drug Library Management defects in the software: 1) DLM software does not allow user to create percentage dose rate or rate change values with certain limits, potentially resulting in over-delivery to patient. 2) An unau 12 US, 3 OUS

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-11-24 Class II Software Design Change Software issue only allows Concentration Limits to be defined to one digit of precision past the decimal point (0.1) instead of three digits (0.001). If the user is unable to use Concentration Limits as intended, they may need to change the 12 customers
2025-11-24 Class II Software Design Change For certain customers, the Change Summary review option ceases to operate as expected for any migrated library after the migration has been completed. Users must use alternate methods to review changes. Failure to do so may lead in over del 7 customers

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer