LifeShield Infusion Safety Software Suite

LifeShield Infusion Safety Software Suite manages data for compatible Plum Duo and Plum Solo infusion pumps. The cloud-based platform provides drug library management, clinical dashboards…

Registry build 21.09.26

LifeShield Infusion Safety Software Suite manages data for compatible Plum Duo and Plum Solo infusion pumps. The cloud-based platform provides drug library management, clinical dashboards and data exchange with hospital information systems.

Pharmacists use Drug Library Management to configure approved pump libraries. Clinical Dashboards and Reports displays infusion or device information, while Data Flow Management routes pharmacy-validated orders and pump information between connected systems.

Listed Item

GTIN for 17005-02, 1/EA

Clinical Control

The suite does not remotely control or program pumps or manage alarms by clearing or silencing them. A trained healthcare professional enters and validates infusion parameters at the pump. Its use follows the connected pump’s adult, pediatric or neonatal indications.

1manufacturer
3catalogue numbers in this listing
3510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Registered in Shanghai. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code PHC
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31

Record

Regulatory record for LifeShield Infusion Safety Software Suite
Listed by ICU Medical, Inc, United States
FDA product code PHC
Device type Infusion Safety Management Software
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K242117
Record published 2025-05-23
Record revised 2025-10-17 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for LifeShield Infusion Safety Software Suite
Catalogue number Size Status
17005-02 In distribution
17003-02 In distribution
17002-02 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Ivenix Infusion System Fresenius Kabi AB 6
BD Intelliport Becton, Dickinson AND Company 5
PharmGuard ICU Medical, Inc 4
Dose IQ Safety Software Baxter Healthcare Corporation 3
Alaris CareFusion 303, Inc 3
ICU Medical MedNet ICU Medical, Inc 3
LifeShield Infusion Safety Software Suite – LifeShield CDR ICU Medical, Inc 2
Alaris™ Guardrails™ Editor Software Kit, Model 8961 CareFusion 303, Inc 2
BD Alaris CareFusion 303, Inc 1
BD Alaris™ System Manager 9601, Software CareFusion 303, Inc 1
Vigilant Software Suite Fresenius Kabi AB 1
BD Intelliport System Becton, Dickinson AND Company 1

Showing 12 of 20. All products under Infusion Safety Management Software

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252130 2026-04-02
K242117 2025-04-02
K223606 2023-08-24

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of LifeShield Infusion Safety Software Suite
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
ICU Medical, Inc 510(k) number 2025-11-24 Class II Software Design Change For certain customers, the Change Summary review option ceases to operate as expected for any migrated library after the migration has been completed. Users must use alternate methods to review changes. Failure to do so may lead in over del 7 customers
ICU Medical, Inc 510(k) number 2025-11-24 Class II Software Design Change Software issue only allows Concentration Limits to be defined to one digit of precision past the decimal point (0.1) instead of three digits (0.001). If the user is unable to use Concentration Limits as intended, they may need to change the 12 customers

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-05-02 Class II Software Design Change Firm has identified Drug Library Management defects in the software: 1) DLM software does not allow user to create percentage dose rate or rate change values with certain limits, potentially resulting in over-delivery to patient. 2) An unau 12 US, 3 OUS

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer