Omnipod 5 Controller
Omnipod 5 Controller (mg/dl) Included in Starter Kits (variable options w/ or w/out Pods or PodPals)
Who Else Makes It
All of them in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
Record
| Listed by | Insulet Corporation, United States |
|---|---|
| FDA product code | QFG |
| Device type | Alternate Controller Enabled Insulin Infusion Pump |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5730 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2022-02-25 |
| Record revised | 2025-12-02 (version 4) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date, serial number |
| Packaging | Starter kit w/ p&p, starter kit w/ pals, starter kit w/o pals, starter kit w/pals |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| PDM-H001-G-XX | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Tandem Mobi Autosoft XC Kit | Tandem Diabetes Care, Inc. | 13 |
| t:slim X2 Insulin Pump with Control-IQ+ Technology | Tandem Diabetes Care, Inc. | 12 |
| t:slim X2 Insulin Pump with Control-IQ | Tandem Diabetes Care, Inc. | 11 |
| t:slim X2 Insulin Pump with Basal-IQ | Tandem Diabetes Care, Inc. | 9 |
| Tandem Mobi | Tandem Diabetes Care, Inc. | 5 |
| MiniMed Flex | Medtronic Minimed | 4 |
| Tandem Mobi Autosoft 30 Kit | Tandem Diabetes Care, Inc. | 4 |
| Omnipod 5 Pod | Insulet Corporation | 3 |
| Tandem Mobi TruSteel Kit | Tandem Diabetes Care, Inc. | 3 |
| Tandem Mobi Cartridge | Tandem Diabetes Care, Inc. | 3 |
| MiniMed Flex Starter Kit | Medtronic, Inc. | 2 |
| Omnipod 5 Controller APP | Insulet Corporation | 2 |
Showing 12 of 36. All products under Alternate Controller Enabled Insulin Infusion Pump
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K231826 | 2023-10-18 |
| K203768 | 2022-01-27 |
| K191679 | 2019-09-20 |
Recalls
3 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-05-20 | Class I | Process design | External soft cannula damage during manufacturing that results in insulin leaking around the Pod instead of being delivered to the user regardless of basal or bolus delivery. The primary failure mode is pump under-delivery due to loss of in | 4,936,056 units |
| 2026-03-12 | Class I | Process design | Due to a manufacturing defect, certain Omnipod 5 Pods from 49 lots have an internal soft cannula tear that results in insulin leaking into the Pod instead of being delivered to the user regardless of basal or bolus delivery. This defect res | 1,240,115 units |
| 2023-11-30 | Class I | Software design | The bolus calculator is not recording the decimal point if it is the first value entered when changing a bolus dose. This may lead to an over-delivery of insulin to the user if the user does not recognize the error on the bolus calculator s | 27000 users |
| 2023-02-28 | Class II | Software Design Change | An error message was received when using the Omnipod 5 App on compatible smartphones that prevented phone control users from controlling the Omnipod 5 Automated Insulin Delivery System from their Omnipod 5 App which may cause a delay in the | 11,016 users |
| 2022-11-14 | Class II | Device Design | The firm has become aware of an issue with the Omnipod 5 Controller where the Controller charging port and charging cable are melting, deforming, or discoloring due to heat generated by increased resistance in the Controller port. The exces | 129,086 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.