Omnipod 5 Starter Kit

Omnipod 5 Starter Kit mg/dl

Registry build 21.09.26
2manufacturers in China registered for this device type
1catalogue number
3510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

All of them in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code QFG
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44

Record

Regulatory record for Omnipod 5 Starter Kit
Listed by Insulet Corporation, United States
FDA product code QFG
Device type Alternate Controller Enabled Insulin Infusion Pump
Device class Class 2
Regulation 21 CFR 880.5730
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2024-02-22
Record revised 2024-07-29 (version 2)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Storage environment temperature 32 to 86 °F; Storage environment humidity 20 to 90 % RH; Storage environment atmospheric pressure 700 to 1060 KiloPascal

Catalogue Numbers

Catalogue numbers for Omnipod 5 Starter Kit
Catalogue number Size Status
SKT-M001-G-X9 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Tandem Mobi Autosoft XC Kit Tandem Diabetes Care, Inc. 13
t:slim X2 Insulin Pump with Control-IQ+ Technology Tandem Diabetes Care, Inc. 12
t:slim X2 Insulin Pump with Control-IQ Tandem Diabetes Care, Inc. 11
t:slim X2 Insulin Pump with Basal-IQ Tandem Diabetes Care, Inc. 9
Tandem Mobi Tandem Diabetes Care, Inc. 5
MiniMed Flex Medtronic Minimed 4
Tandem Mobi Autosoft 30 Kit Tandem Diabetes Care, Inc. 4
Omnipod 5 Pod Insulet Corporation 3
Tandem Mobi TruSteel Kit Tandem Diabetes Care, Inc. 3
Tandem Mobi Cartridge Tandem Diabetes Care, Inc. 3
MiniMed Flex Starter Kit Medtronic, Inc. 2
Omnipod 5 Controller APP Insulet Corporation 2

Showing 12 of 36. All products under Alternate Controller Enabled Insulin Infusion Pump

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K231826 2023-10-18
K203768 2022-01-27
K191679 2019-09-20

Recalls

3 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-05-20 Class I Process design External soft cannula damage during manufacturing that results in insulin leaking around the Pod instead of being delivered to the user regardless of basal or bolus delivery. The primary failure mode is pump under-delivery due to loss of in 4,936,056 units
2026-03-12 Class I Process design Due to a manufacturing defect, certain Omnipod 5 Pods from 49 lots have an internal soft cannula tear that results in insulin leaking into the Pod instead of being delivered to the user regardless of basal or bolus delivery. This defect res 1,240,115 units
2023-11-30 Class I Software design The bolus calculator is not recording the decimal point if it is the first value entered when changing a bolus dose. This may lead to an over-delivery of insulin to the user if the user does not recognize the error on the bolus calculator s 27000 users
2023-02-28 Class II Software Design Change An error message was received when using the Omnipod 5 App on compatible smartphones that prevented phone control users from controlling the Omnipod 5 Automated Insulin Delivery System from their Omnipod 5 App which may cause a delay in the 11,016 users
2022-11-14 Class II Device Design The firm has become aware of an issue with the Omnipod 5 Controller where the Controller charging port and charging cable are melting, deforming, or discoloring due to heat generated by increased resistance in the Controller port. The exces 129,086

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer