Kumar T-Anchors® Hernia Set
The Kumar T-ANCHORS® Hernia Set provides a means of Fixation of the Mesh in Laparoscopic or Open Repair of Abdominal Wall Hernia as Trans-fascial sutures, in addition to the tackers. Kumar…
The Kumar T-ANCHORS® Hernia Set provides a means of Fixation of the Mesh in Laparoscopic or Open Repair of Abdominal Wall Hernia as Trans-fascial sutures, in addition to the tackers. Kumar T-ANCHORS® eliminate the need for grasping and feeding of sutures into a Suture Passer.
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Zhejiang (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Hangzhou Fushan Medical Appliance Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 44 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Zhangjiagang Municipal Cnnc Huakang Radiation Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 17 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Beijing Biosis Healing Biological Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| B.j.zh.f.panther Medical Equipment Co., Ltd. | Beijing | Beijing | Manufacturer | 6 |
| Touchstone International Medical Science Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 5 |
| Sinolinks Medical Innovation, Inc. | Changzhou | Jiangsu | Complaint-file establishment | 5 |
| Victor Medical Instruments Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 5 |
| Lucky Star Lrradiation Science Co., Ltd. Shanghai | Shanghai | Shanghai | Contract manufacturer | 5 |
| Fengh Medical Co., Ltd. | Jiangyin | Jiangsu | Manufacturer | 4 |
| Medtronic (Shanghai) Medical Technology Co., Ltd. | Min Hang District | Shanghai | Specification developer | 4 |
Showing 12 of 16. All 16 manufacturers in China registered for Staple, Implantable
Record
| Listed by | Nashville Surgical Instruments, United States |
|---|---|
| FDA product code | GDW |
| Device type | Staple, Implantable |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4750 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K081366 |
| Record published | 2017-08-15 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment humidity 30 to 70 % RH; Storage environment temperature 45 to 85 °F |
| Packaging | Box of 10 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| TA-008 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Endo GIA | Covidien LP | 51 |
| Aeon | Lexington Medical, Inc. | 48 |
| Proximate | Ethicon Endo-Surgery, Inc. | 42 |
| Tri-Staple 2.0 | Covidien LP | 42 |
| EEA | Covidien LP | 37 |
| Echelon Endopath | Ethicon Endo-Surgery, Inc. | 33 |
| Reloading Unit for Endo Linear Cutter Stapler | B.j.zh.f.panther Medical Equipment Co., Ltd. | 28 |
| GIA | Covidien LP | 24 |
| easyEndoTM Universal Linear Cutting Stapler and Loading Units for Single Use | Ezisurg Medical Co., Ltd. | 23 |
| Circular Stapler | B.j.zh.f.panther Medical Equipment Co., Ltd. | 23 |
| Endopath | Ethicon Endo-Surgery, Inc. | 22 |
| Signia | Covidien LP | 19 |
Showing 12 of 105. All products under Staple, Implantable
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.