Aesculap
HI-Line XXS Disp.diamond Burr III D5.0MM
Who Else Makes It
Concentrated in Guangdong (5), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Shenzhen Jinlichang Electronic Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 1 |
| Dongguan Wanjin Industrial Co., Ltd. | Dongguang | Guangdong | Remanufacturer | 41 |
| Guangzhou Ajax Medical Equipment Co Ltd | Guangzhou | Guangdong | Manufacturer | 13 |
| Shenzhen Soga Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 7 |
| Ningbo Advan Electrical Co., Ltd. | Cixi | Zhejiang | Contract manufacturer | 5 |
Record
| Listed by | Aesculap AG, Germany |
|---|---|
| FDA product code | GEY |
| Device type | Motor, Surgical Instrument, Ac-Powered |
| Device class | Class 1 |
| Regulation | 21 CFR 878.4820 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2020-04-24 |
| Record revised | 2021-05-07 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, serial number |
| Distribution end date | 2026-05-29 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| GB551SU | In distribution | ||
| GD051R | In distribution | ||
| GD394R | 5 | In distribution | |
| GE848SU | In distribution | ||
| GC925R | In distribution | ||
| GD047R | In distribution | ||
| GD390R | 5 | In distribution | |
| GA263SU | In distribution | ||
| GD392R | 5 | In distribution | |
| GA261SU | In distribution | ||
| GB695R | In distribution | ||
| GD152R | In distribution | ||
| GC926R | In distribution | ||
| GD255R | In distribution | ||
| GD132R | In distribution | ||
| GD145R | In distribution | ||
| GE835SU | In distribution | ||
| GC380R | In distribution | ||
| GD393R | 5 | In distribution | |
| GD391R | 5 | In distribution | |
| GC314R | In distribution | ||
| GD397R | 5 | In distribution | |
| GD035R | In distribution | ||
| GD225R | In distribution | ||
| GD082R | In distribution | ||
| GD135R | In distribution | ||
| GD071R | In distribution | ||
| GC880R | In distribution | ||
| GB696R | In distribution | ||
| GD396R | 5 | In distribution | |
| GE818SU | In distribution | ||
| GA264SU | In distribution | ||
| GD062R | In distribution | ||
| GE805SU | In distribution | ||
| GA223R | In distribution | ||
| GA258SU | In distribution | ||
| GD024R | In distribution | ||
| GD072R | In distribution | ||
| GD951R | 5 | In distribution | |
| GD231R | In distribution | ||
| GB693 | 10 | In distribution | |
| GD248R | In distribution | ||
| GE842SU | In distribution | ||
| GD085R | In distribution | ||
| GC378R | In distribution | ||
| GD034R | In distribution | ||
| GD073R | In distribution | ||
| GD250R | In distribution | ||
| GD151R | In distribution | ||
| GA259SU | In distribution | ||
| GD232R | In distribution | ||
| GA262SU | In distribution | ||
| GD395R | 5 | In distribution | |
| GA156 | In distribution | ||
| GD230R | In distribution | ||
| GD044R | In distribution | ||
| GD063R | In distribution | ||
| GD950R | 5 | In distribution | |
| GD247R | In distribution | ||
| GD033R | In distribution | ||
| GD227R | In distribution | ||
| GC644R | Withdrawn | ||
| GP494R | 5 | Withdrawn | |
| GC491R | Withdrawn | ||
| GA222R | Withdrawn | ||
| GP545R | 5 | Withdrawn | |
| GP544R | 5 | Withdrawn | |
| GA228R | Withdrawn | ||
| GE812SU | Withdrawn | ||
| GP497R | 5 | Withdrawn | |
| GA227R | Withdrawn | ||
| GA221R | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| De Soutter Medical | DE Soutter Medical Ltd. | 1,481 |
| HI-Line XS | Aesculap AG | 169 |
| Zaguar | Imedicom Co., Ltd. | 131 |
| Elan 4 | Aesculap AG | 107 |
| HI-Line | Aesculap AG | 53 |
| Motor, Surgical Instrument, Ac-Powered | Anspach Effort, The | 37 |
| Zimmer Biomet™ | Zimmer Surgical, Inc. | 29 |
| Motor, Surgical Instrument, Ac-Powered | Synthes Gmbh | 29 |
| HI-Line XXS | Aesculap AG | 22 |
| Motor, Surgical Instrument, Ac-Powered | Smith & Nephew, Inc. | 20 |
| Eccos | Aesculap AG | 11 |
| Motor, Surgical Instrument, Ac-Powered | Richard Wolf Gmbh | 10 |
Showing 12 of 149. All products under Motor, Surgical Instrument, Ac-Powered
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K913262 | 1991-12-30 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-03-28 | Class II | Process control | Diamond particulates may break off the burr and fall into the surgical site. If the particles are not detected and are not removed from the surgical site a foreign body reaction may occur. These particulates could also lead to mechanically | total amount of burrs – 608 | 2018-02-06 |
| 2017-03-28 | Class II | Process control | Diamond particulates may break off the burr and fall into the surgical site. If the particles are not detected and are not removed from the surgical site a foreign body reaction may occur. These particulates could also lead to mechanically | total of all burrs 608 units | 2018-02-06 |
| 2017-03-28 | Class II | Process control | Diamond particulates may break off the burr and fall into the surgical site. If the particles are not detected and are not removed from the surgical site a foreign body reaction may occur. These particulates could also lead to mechanically | Total of all burrs – 608 units | 2018-02-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.