HI-Line XS
HI-Line XS Disp.lindemann Cutter II 20MM
Who Else Makes It
Concentrated in Guangdong (5), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Shenzhen Jinlichang Electronic Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 1 |
| Dongguan Wanjin Industrial Co., Ltd. | Dongguang | Guangdong | Remanufacturer | 41 |
| Guangzhou Ajax Medical Equipment Co Ltd | Guangzhou | Guangdong | Manufacturer | 13 |
| Shenzhen Soga Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 7 |
| Ningbo Advan Electrical Co., Ltd. | Cixi | Zhejiang | Contract manufacturer | 5 |
Record
| Listed by | Aesculap AG, Germany |
|---|---|
| FDA product code | GEY |
| Device type | Motor, Surgical Instrument, Ac-Powered |
| Device class | Class 1 |
| Regulation | 21 CFR 878.4820 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2016-06-07 |
| Record revised | 2021-10-29 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2023-04-28 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| GE523SU | In distribution | |
| GE631SU | In distribution | |
| GE648SU | In distribution | |
| GE419SU | In distribution | |
| GE418SU | In distribution | |
| GE390SU | In distribution | |
| GE406SU | In distribution | |
| GE549SU | In distribution | |
| GE298SU | In distribution | |
| GE603SU | In distribution | |
| GE501SU | In distribution | |
| GE407SU | In distribution | |
| GE394SU | In distribution | |
| GE409SU | In distribution | |
| GE609SU | In distribution | |
| GE508SU | In distribution | |
| GE617SU | In distribution | |
| GE537SU | In distribution | |
| GE395SU | In distribution | |
| GE533SU | In distribution | |
| GE530SU | In distribution | |
| GE398SU | In distribution | |
| GE415SU | In distribution | |
| GE416SU | In distribution | |
| GE459SU | In distribution | |
| GE616SU | In distribution | |
| GE502SU | In distribution | |
| GB762SU | In distribution | |
| GE650SU | In distribution | |
| GE525SU | In distribution | |
| GE431SU | In distribution | |
| GE556SU | In distribution | |
| GE515SU | In distribution | |
| GE405SU | In distribution | |
| GE420SU | In distribution | |
| GE414SU | In distribution | |
| GE507SU | In distribution | |
| GE629SU | In distribution | |
| GE718SU | In distribution | |
| GE635SU | In distribution | |
| GE473SU | In distribution | |
| GE437SU | In distribution | |
| GE294SU | In distribution | |
| GE657SU | In distribution | |
| GE408SU | In distribution | |
| GE401SU | In distribution | |
| GE433SU | In distribution | |
| GE430SU | In distribution | |
| GE628SU | In distribution | |
| GE558SU | In distribution | |
| GE529SU | In distribution | |
| GE392SU | In distribution | |
| GE634SU | In distribution | |
| GE471SU | In distribution | |
| GE469SU | In distribution | |
| GE635TC-SU | In distribution | |
| GE391SU | In distribution | |
| GE619SU | In distribution | |
| GE555SU | In distribution | |
| GE432SU | In distribution | |
| GE500SU | In distribution | |
| GE425SU | In distribution | |
| GE600SU | In distribution | |
| GE608TC-SU | In distribution | |
| GE404SU | In distribution | |
| GE655SU | In distribution | |
| GE606SU | In distribution | |
| GE516SU | In distribution | |
| GE535TC-SU | In distribution | |
| GE508TC-SU | In distribution | |
| GE702SU | In distribution | |
| GE604SU | In distribution | |
| GE509SU | In distribution | |
| GE461SU | In distribution | |
| GE557SU | In distribution | |
| GE646SU | In distribution | |
| GE504SU | In distribution | |
| GE521SU | In distribution | |
| GE291SU | In distribution | |
| GE507TC-SU | In distribution | |
| GE534SU | In distribution | |
| GE658SU | In distribution | |
| GE615SU | In distribution | |
| GE613SU | In distribution | |
| GE505SU | In distribution | |
| GE708SU | In distribution | |
| GE653SU | In distribution | |
| GB767SU | In distribution | |
| GE511SU | In distribution | |
| GE535SU | In distribution | |
| GE417SU | In distribution | |
| GE656SU | In distribution | |
| GE540SU | In distribution | |
| GE607TC-SU | In distribution | |
| GE522SU | In distribution | |
| GE457SU | In distribution | |
| GE514SU | In distribution | |
| GE513SU | In distribution | |
| GE518SU | In distribution | |
| GE456SU | In distribution | |
| GE512SU | In distribution | |
| GE296SU | In distribution | |
| GE463SU | In distribution | |
| GE389SU | In distribution | |
| GE548SU | In distribution | |
| GE293SU | In distribution | |
| GE528SU | In distribution | |
| GE614SU | In distribution | |
| GB763SU | In distribution | |
| GE460SU | In distribution | |
| GE546SU | In distribution | |
| GE608SU | In distribution | |
| GE532SU | In distribution | |
| GE475SU | In distribution | |
| GE519SU | In distribution | |
| GE524SU | In distribution | |
| GE286SU | In distribution | |
| GE435SU | In distribution | |
| GE618SU | In distribution | |
| GE506SU | In distribution | |
| GE700SU | In distribution | |
| GE605SU | In distribution | |
| GE292SU | In distribution | |
| GE412SU | In distribution | |
| GE717SU | In distribution | |
| GE542SU | In distribution | |
| GE520SU | In distribution | |
| GE553SU | In distribution | |
| GE503SU | In distribution | |
| GE714SU | In distribution | |
| GE620SU | In distribution | |
| GE607SU | In distribution | |
| GB764SU | In distribution | |
| GB761SU | In distribution | |
| GE517SU | In distribution | |
| GE413SU | In distribution | |
| GE403SU | In distribution | |
| GE712SU | In distribution | |
| GE424SU | In distribution | |
| GE644SU | In distribution | |
| GE625SU | In distribution | |
| GE429SU | In distribution | |
| GE435TC-SU | Withdrawn | |
| GE411SU | Withdrawn | |
| GE704SU | Withdrawn | |
| GE706SU | Withdrawn | |
| GE719SU | Withdrawn | |
| GE288SU | Withdrawn | |
| GE397SU | Withdrawn | |
| GE716SU | Withdrawn | |
| GE654SU | Withdrawn | |
| GE290SU | Withdrawn | |
| GE707SU | Withdrawn | |
| GE550SU | Withdrawn | |
| GE711SU | Withdrawn | |
| GE531SU | Withdrawn | |
| GE464SU | Withdrawn | |
| GE407TC-SU | Withdrawn | |
| GE396SU | Withdrawn | |
| GE402SU | Withdrawn | |
| GE465SU | Withdrawn | |
| GE408TC-SU | Withdrawn | |
| GE574SU | Withdrawn | |
| GE729SU | Withdrawn | |
| GE295SU | Withdrawn | |
| GE434SU | Withdrawn | |
| GE649SU | Withdrawn | |
| GE624SU | Withdrawn | |
| GE709SU | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| De Soutter Medical | DE Soutter Medical Ltd. | 1,481 |
| Zaguar | Imedicom Co., Ltd. | 131 |
| Elan 4 | Aesculap AG | 107 |
| Aesculap | Aesculap AG | 72 |
| HI-Line | Aesculap AG | 53 |
| Motor, Surgical Instrument, Ac-Powered | Anspach Effort, The | 37 |
| Zimmer Biomet™ | Zimmer Surgical, Inc. | 29 |
| Motor, Surgical Instrument, Ac-Powered | Synthes Gmbh | 29 |
| HI-Line XXS | Aesculap AG | 22 |
| Motor, Surgical Instrument, Ac-Powered | Smith & Nephew, Inc. | 20 |
| Eccos | Aesculap AG | 11 |
| Motor, Surgical Instrument, Ac-Powered | Richard Wolf Gmbh | 10 |
Showing 12 of 149. All products under Motor, Surgical Instrument, Ac-Powered
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K913262 | 1991-12-30 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-03-28 | Class II | Process control | Diamond particulates may break off the burr and fall into the surgical site. If the particles are not detected and are not removed from the surgical site a foreign body reaction may occur. These particulates could also lead to mechanically | total amount of burrs – 608 | 2018-02-06 |
| 2017-03-28 | Class II | Process control | Diamond particulates may break off the burr and fall into the surgical site. If the particles are not detected and are not removed from the surgical site a foreign body reaction may occur. These particulates could also lead to mechanically | total of all burrs 608 units | 2018-02-06 |
| 2017-03-28 | Class II | Process control | Diamond particulates may break off the burr and fall into the surgical site. If the particles are not detected and are not removed from the surgical site a foreign body reaction may occur. These particulates could also lead to mechanically | Total of all burrs – 608 units | 2018-02-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.