Codman Microsensor

CODMAN MICROSENSOR Ventricular Catheter Kit With ICP Sensor Contains (1) Microsensor Ventricular Catheter, (1) Tunneling Trocar, (1) Catheter Anchoring Clip

Registry build 21.09.26
5manufacturers in China registered for this device type
12catalogue numbers in this listing
12recalls on this code

Who Else Makes It

Concentrated in Guangdong (3), Shanghai (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GWM
Manufacturer City Province Registered as Device types
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
PAN-International Precision Electronic Co., Ltd. Dongguan Guangdong Contract manufacturer 4
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
Shanghai Wilpower Industrial Co., Ltd. Shanghai Shanghai Exporter 33

Record

Regulatory record for Codman Microsensor
Listed by Cerenovus, Inc., United States
FDA product code GWM
Device type Device, Monitoring, Intracranial Pressure
Device class Class 2
Regulation 21 CFR 882.1620
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K153347
Record published 2016-12-14
Record revised 2023-09-15 (version 8)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Ethylene Oxide
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, serial number
Storage Special storage condition: Waste from electrical and electronic equipment
Distribution end date 2022-09-01

Catalogue Numbers

Catalogue numbers for Codman Microsensor
Catalogue number Size Status
626631US Withdrawn
626632US Withdrawn
82-6631 Withdrawn
82-6638 Withdrawn
82-6621 Withdrawn
82-6653 Withdrawn
626633US Withdrawn
626653US Withdrawn
82-6632 Withdrawn
82-6605SP Withdrawn
626638US Withdrawn
82-6633 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Licox® GMS, Gesellschaft für medizinische Sondentechnik mbH 38
Sophysa Sophysa 32
Becker® Medtronic PS Medical 31
Codman Cerenovus, Inc. 29
Device, Monitoring, Intracranial Pressure Medtronic PS Medical 28
Exacta™ Medtronic PS Medical 28
Braincare Braincare Desenvolvimento E Inovacao Tecnologica SA 24
Camino® Integra Lifesciences (Ireland) Limited 20
Codman® Integra LifeSciences Production Corporation 19
Integra® Integra Lifesciences (Ireland) Limited 17
Aura Branchpoint & Aura Development LLC 17
Natus Natus Medical Incorporated 15

Showing 12 of 133. All products under Device, Monitoring, Intracranial Pressure

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Codman Microsensor
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Integra Lifesciences Corporation 510(k) number 2025-12-12 Class II Process control Potential corrosion stains on the surface of the 14-gauge Tuohy Needle that is included in the Microsensor and Cerelink ICP Kits. 1,301 units
Integra Lifesciences Corporation 510(k) number 2023-04-11 Class II Under Investigation by firm Released with discoloration (rust) on the Drill Chuck and inner chuck of Codman Cranial Hand Drill may result in inflammation, local toxicity, systemic toxicity, sensitivity, revision surgery, procedural delay, inconvenience to user, and/or 337 units
Cerenovus, Inc. 510(k) number 2011-10-25 Not classified Labeling Change Control Incorrect version of Instructions for Use (IFU) for the Xylocaine product that is supplied with the Cranial kits. 861 units 2015-05-29
Cerenovus, Inc. 510(k) number 2011-10-25 Not classified Labeling Change Control Incorrect version of Instructions for Use (IFU) for the Xylocaine product that is supplied with the Cranial kits. 13845 units 2015-05-29

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2012-02-09 Not classified Nonconforming Material/Component Codman ICP Skull Bolt wrench is out of specification and cannot be used to turn the screw on the drill 4056 kits 2015-09-11
2011-10-25 Not classified Labeling Change Control Incorrect version of Instructions for Use (IFU) for the Xylocaine product that is supplied with the Cranial kits. 462 units 2015-05-29
2011-10-25 Not classified Labeling Change Control Incorrect version of Instructions for Use (IFU) for the Xylocaine product that is supplied with the Cranial kits. 2827 units 2015-05-29
2011-10-25 Not classified Labeling Change Control Incorrect version of Instructions for Use (IFU) for the Xylocaine product that is supplied with the Cranial kits. 254 units 2015-05-29
2010-11-30 Not classified Package design/selection Packaging defect may compromise sterility of device 1671 units 2013-03-14
2010-11-30 Not classified Package design/selection Packaging defect may compromise sterility of device 9038 units 2013-03-14
2010-11-30 Not classified Package design/selection Packaging defect may compromise sterility of device 44 units 2013-03-14
2010-11-30 Not classified Package design/selection Packaging defect may compromise sterility of device 226 units 2013-03-14
2010-11-30 Not classified Package design/selection Packaging defect may compromise sterility of device 2264 units 2013-03-14
2010-11-30 Not classified Package design/selection Packaging defect may compromise sterility of device 1549 units 2013-03-14

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer