Multi-RF Therapy Cable

Catalogue number SRX-CRG-MRF, listed by Avanos Medical, Inc., United States, under Generator, Lesion, Radiofrequency. 2 manufacturers in China are registered for this product code.

Registry build 21.09.26
2manufacturers in China registered for this device type
1catalogue number
2510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Guangdong (1), Shanghai (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code GXD
Manufacturer City Province Registered as Device types
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
Cathay Manufacturing Corp. Shanghai Shanghai Contract manufacturer 5

Record

Regulatory record for Multi-RF Therapy Cable
Listed by Avanos Medical, Inc., United States
FDA product code GXD
Device type Generator, Lesion, Radiofrequency
Device class Class 2
Regulation 21 CFR 882.4400
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K192491
Record published 2020-10-16
Record revised 2023-06-22 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Multi-RF Therapy Cable
Catalogue number Size Status
SRX-CRG-MRF In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Generator, Lesion, Radiofrequency Boston Scientific Neuromodulation Corporation 68
Generator, Lesion, Radiofrequency Stryker Leibinger Gmbh & Co. KG 58
OneRF Ablation System Neuroone Medical Technologies Corp. 7
GX1™ Boston Scientific Neuromodulation Corporation 7
Accurian Medtronic Sofamor Danek, Inc. 7
Multigen 2 Stryker GmbH 6
Avanos* Avanos Medical, Inc. 4
OWL Diros Technology, Inc. 4
NeuroTherm™ Neurotherm, Inc. 3
Halyard Avanos Medical, Inc. 3
Venom Multigen 2 Stryker GmbH 2
Relievant Relievant Medsystems 2

Showing 12 of 26. All products under Generator, Lesion, Radiofrequency

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K242057 2024-08-14
K192491 2020-02-21

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Multi-RF Therapy Cable
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Avanos Medical, Inc. 510(k) number 2023-08-01 Class II Process change control Avanos has received an increase in complaints from customers for COOLIEF RF Generators producing F100 and F101 faults. 24 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer