“1MM” System
7 catalogue numbers from 01-7585, listed by Biomet Microfixation, United States, under Fastener, Plate, Cranioplasty. 3 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (1), Shanghai (1), Fujian (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Quanzhou Apex Hygiene Products Co., Ltd. | Jinjiang | Fujian | Manufacturer | 8 |
Record
| Listed by | Biomet Microfixation, United States |
|---|---|
| FDA product code | HBW |
| Device type | Fastener, Plate, Cranioplasty |
| Device class | Class 2 |
| Regulation | 21 CFR 882.5360 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K121589 |
| Record published | 2015-10-11 |
| Record revised | 2025-06-09 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 01-7585 | In distribution | |
| 01-7413 | In distribution | |
| 01-7405 | In distribution | |
| 01-7403 | In distribution | |
| 01-7402 | In distribution | |
| 01-7504 | In distribution | |
| 01-7404 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| 1.5MM System | Biomet Microfixation | 87 |
| Neuro Plating System | Osteonic Co., Ltd. | 55 |
| Universal Neuro 3 | Stryker Leibinger Gmbh & Co. KG | 40 |
| “2.0MM” System | Biomet Microfixation | 26 |
| Resorb XG, Sterile | KLS-Martin L.P. | 18 |
| Leforte Neuro System Bone Plate | Jeil Medical Corporation | 15 |
| CMF System | Biomet Microfixation | 14 |
| Fastener, Plate, Cranioplasty | Biomet Microfixation | 14 |
| AXS | Stryker Leibinger Gmbh & Co. KG | 14 |
| Raas Cranial Plating System | Alliance Partners, LLC | 12 |
| Thinflap System | Biomet Microfixation | 12 |
| Delta | Stryker Leibinger Gmbh & Co. KG | 11 |
Showing 12 of 45. All products under Fastener, Plate, Cranioplasty
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet Microfixation | 510(k) number | 2015-08-06 | Class II | Component change control | The lids on implant caddies within P/N 17-5000 and 19-5000 could not be opened by the user without application of undesirable/unexpected excessive force. | 37 cases | 2017-10-13 |
| Biomet Microfixation | 510(k) number | 2015-08-06 | Class II | Component change control | The lids on implant caddies within P/N 17-5000 and 19-5000 could not be opened by the user without application of undesirable/unexpected excessive force. | 5 units | 2017-10-13 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.