Beaver-Visitec

Malosa Core SMILE Pack 2-Beaver-Visitec International Ltd (30/SP)

Registry build 21.09.26
3manufacturers in China registered for this device type
6catalogue numbers in this listing
6recalls on this code

Who Else Makes It

Concentrated in Zhejiang (1), Hubei (1), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code PZG
Manufacturer City Province Registered as Device types
Malosa Medical Instruments (Changshu) Limited Changshu Jiangsu Contract manufacturer 24
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
Hubei Lanbin Medical Group Co., Ltd. Xiaogan Hubei Contract manufacturer 33

Record

Regulatory record for Beaver-Visitec
Listed by Beaver-Visitec International, Ltd, United Kingdom
FDA product code PZG
Device type Surgical Eye Tray
Device class Class 1
Regulation 21 CFR 886.4350
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2021-11-15
Record revised 2022-02-17 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Beaver-Visitec
Catalogue number Size Per pack Status
MMK834/1 30 In distribution
MMK967 30 In distribution
MMK100/2 20 In distribution
MMK884 20 In distribution
MMK883/2 30 In distribution
MMK110/3 20 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Readypak Beaver-Visitec International, Ltd 72
Stradis Healthcare Stradis Healthcare 49
Stradis Stradis Healthcare 17
Kaiser Permanente Kit Pack Oasis Medical, Inc. 16
Surgeon’s Choice Card Oasis Medical, Inc. 16
CustomEyes® Beaver-Visitec International, Ltd 9
Anodyne Surgical Psi/Eye-Ko, Inc. 7
Invenio GRI Medical & Electronic Technology Co., Ltd. 3
Stockton Kit 2 Blink Medical Ltd 2
Cataract Inst Set – Spokane Anderson Blink Medical Ltd 2
Sub Tenon Set – Fine Tip Blink Medical Ltd 2
Stockton Kit 1 Blink Medical Ltd 2

Showing 12 of 79. All products under Surgical Eye Tray

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 920 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 1170 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 30 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 680 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 120 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 380 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer