Readypak

Custom Readypak #584089 (1/EA)

Registry build 21.09.26
3manufacturers in China registered for this device type
72catalogue numbers in this listing
6recalls on this code

Who Else Makes It

Concentrated in Zhejiang (1), Hubei (1), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code PZG
Manufacturer City Province Registered as Device types
Malosa Medical Instruments (Changshu) Limited Changshu Jiangsu Contract manufacturer 24
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
Hubei Lanbin Medical Group Co., Ltd. Xiaogan Hubei Contract manufacturer 33

Record

Regulatory record for Readypak
Listed by Beaver-Visitec International, Ltd, United Kingdom
FDA product code PZG
Device type Surgical Eye Tray
Device class Class 1
Regulation 21 CFR 886.4350
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2024-06-27

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Radiation Sterilization
Supplied sterile Yes
Single use Yes
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Storage Special storage condition: Store in a dry place.

Catalogue Numbers

Catalogue numbers for Readypak
Catalogue number Size Status
58000601 In distribution
584838 In distribution
584846 In distribution
584825 In distribution
584854 In distribution
58000089 In distribution
58000783 In distribution
583813 In distribution
58000609 In distribution
58000156 In distribution
584961 In distribution
584922 In distribution
584089 In distribution
583926 In distribution
584999 In distribution
58000090 In distribution
584940 In distribution
583909 In distribution
584007 In distribution
58000113 In distribution
584949 In distribution
584088 In distribution
584895 In distribution
58000130 In distribution
584888 In distribution
584997 In distribution
584852 In distribution
584843 In distribution
58000131 In distribution
584936 In distribution
584822 In distribution
584884 In distribution
584971 In distribution
583922 In distribution
583928 In distribution
58000073 In distribution
584845 In distribution
584933 In distribution
584863 In distribution
583904 In distribution
584824 In distribution
58000220 In distribution
58000173 In distribution
58000129 In distribution
58000098 In distribution
58000187 In distribution
584839 In distribution
58000132 In distribution
584939 In distribution
583840 In distribution
584934 In distribution
58000216 In distribution
584952 In distribution
58000602 In distribution
584842 In distribution
584886 In distribution
584935 In distribution
583865 In distribution
584823 In distribution
58000095 In distribution
584998 In distribution
58000074 In distribution
584983 In distribution
584844 In distribution
58000117 In distribution
58000558 In distribution
584880 In distribution
584938 In distribution
584084 In distribution
583896 In distribution
584937 In distribution
58000186 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Stradis Healthcare Stradis Healthcare 49
Stradis Stradis Healthcare 17
Kaiser Permanente Kit Pack Oasis Medical, Inc. 16
Surgeon’s Choice Card Oasis Medical, Inc. 16
CustomEyes® Beaver-Visitec International, Ltd 9
Anodyne Surgical Psi/Eye-Ko, Inc. 7
Beaver-Visitec Beaver-Visitec International, Ltd 6
Invenio GRI Medical & Electronic Technology Co., Ltd. 3
Stockton Kit 2 Blink Medical Ltd 2
Cataract Inst Set – Spokane Anderson Blink Medical Ltd 2
Sub Tenon Set – Fine Tip Blink Medical Ltd 2
Stockton Kit 1 Blink Medical Ltd 2

Showing 12 of 79. All products under Surgical Eye Tray

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 920 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 1170 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 30 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 680 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 120 units
2021-11-17 Class II Packaging change control Kit packaging may have small holes compromising product sterility 380 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer