Anterior Column Plate, Left
Anterior Column Plate, Left, 14-Hole, PRS RX System
Who Else Makes It
Concentrated in Jiangsu (10), Shanghai (4), Zhejiang (3). 12 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Kingj Medical Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 7 |
| Hangzhou Sino-MIM Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 6 |
| Suzhou AND Science & Technology Development Corp. | Zhangjiagang | Jiangsu | Contract manufacturer | 5 |
| Beijing AK Medical Co., Ltd. | Changping District | Beijing | Contract manufacturer | 3 |
Showing 12 of 22. All 22 manufacturers in China registered for Plate, Fixation, Bone
Record
| Listed by | I.T.S. Gmbh, Austria |
|---|---|
| FDA product code | HRS |
| Device type | Plate, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Establishment | Complaint-file establishment, Manufacturer |
| Record published | 2017-02-01 |
| Record revised | 2026-06-22 (version 8) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 21218-14 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Pectus System | Biomet Microfixation | 4,662 |
| Arthrex® | Arthrex, Inc. | 3,031 |
| Evos | Smith & Nephew, Inc. | 2,235 |
| Peri-Loc | Smith & Nephew, Inc. | 2,196 |
| OsteoMed | Osteomed | 1,961 |
| VariAx | Stryker GmbH | 1,934 |
| Aptus | Medartis Inc. | 1,688 |
| TC-100 | Smith & Nephew, Inc. | 1,639 |
| Plate, Fixation, Bone | Synthes Gmbh | 1,613 |
| Anthem | Globus Medical, Inc. | 1,551 |
| Acumed | Acumed LLC | 1,360 |
| Signex | Osteonic Co., Ltd. | 1,310 |
Showing 12 of 3,530. All products under Plate, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K260958 | 2026-06-16 |
| K260054 | 2026-04-24 |
| K210935 | 2022-08-31 |
| K142418 | 2014-09-26 |
| K131722 | 2013-08-07 |
| K130008 | 2013-06-25 |
Recalls
16 of these are Class II. Class II means a temporary or reversible health consequence. 15 are recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 70 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 292 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 15,517 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 4 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 11 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 46,637 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 120 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 322 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 101 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 1,307 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 176 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 510 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 220 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 12,059 units |
| 2026-01-23 | Class II | No Marketing Application | Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU). | 869 units |
| 2019-05-09 | Class II | Labeling mix-ups | The titanium implant has the wrong article number laser marked on it. | 65 devices |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.