Leos

LEOS Straight Plate, 2 Hole, CMP, Med

Registry build 21.09.26
22manufacturers in China registered for this device type
45catalogue numbers in this listing
11510(k) clearances naming this product code
20recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Zhejiang (3). 12 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HRS
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11
Kingj Medical Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 7
Hangzhou Sino-MIM Technology Co., Ltd. Hangzhou Zhejiang Contract manufacturer 6
Suzhou AND Science & Technology Development Corp. Zhangjiagang Jiangsu Contract manufacturer 5
Beijing AK Medical Co., Ltd. Changping District Beijing Contract manufacturer 3

Showing 12 of 22. All 22 manufacturers in China registered for Plate, Fixation, Bone

Record

Regulatory record for Leos
Listed by Tyber Medical, United States
FDA product code HRS
Device type Plate, Fixation, Bone
Device class Class 2
Regulation 21 CFR 888.3030
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K222465
Record published 2022-10-04
Record revised 2025-11-20 (version 7)

Specifications

Specifications
MRI safety MR Conditional
Single use Yes
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Leos
Catalogue number Size Status
7622-0250 In distribution
7622-0350 In distribution
7622-0060 In distribution
7622-1050 In distribution
7622-1003 In distribution
7622-0020 In distribution
7622-0230 In distribution
7622-1053 In distribution
7622-0141 In distribution
7622-1051 In distribution
7622-2081 In distribution
7622-1250 In distribution
7622-0331 In distribution
7622-0023 In distribution
7622-0140 In distribution
7622-2041 In distribution
7622-0021 In distribution
7622-2000 In distribution
7622-1052 In distribution
7622-3231 In distribution
7622-1002 In distribution
7622-1000 In distribution
7622-0351 In distribution
7622-1001 In distribution
7622-2200 In distribution
7622-0451 In distribution
7622-2040 In distribution
7622-0431 In distribution
7622-3123 In distribution
7622-1252 In distribution
7622-3122 In distribution
7622-0450 In distribution
7622-0040 In distribution
7622-0024 In distribution
7622-1251 In distribution
7622-0022 In distribution
7622-3121 In distribution
7622-3230 In distribution
7622-0430 In distribution
7622-2001 In distribution
7622-0030 In distribution
7622-1253 In distribution
7622-3120 In distribution
7622-2080 In distribution
7622-0330 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Pectus System Biomet Microfixation 4,662
Arthrex® Arthrex, Inc. 3,031
Evos Smith & Nephew, Inc. 2,235
Peri-Loc Smith & Nephew, Inc. 2,196
OsteoMed Osteomed 1,961
VariAx Stryker GmbH 1,934
Aptus Medartis Inc. 1,688
TC-100 Smith & Nephew, Inc. 1,639
Plate, Fixation, Bone Synthes Gmbh 1,613
Anthem Globus Medical, Inc. 1,551
Acumed Acumed LLC 1,360
Signex Osteonic Co., Ltd. 1,310

Showing 12 of 3,530. All products under Plate, Fixation, Bone

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K261207 2026-06-12
K251361 2025-07-30
K242486 2025-03-19
K241218 2024-05-31
K233423 2023-12-21
K233017 2023-12-20
K232652 2023-12-13
K232693 2023-12-04
K222465 2023-03-07
K203817 2021-08-13
K193222 2020-01-20

Recalls

20 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-12-19 Class II Process control The supplier manufactured anatomical left plates with an incorrect thread orientation. 100 units
2025-12-19 Class II Process control The supplier manufactured anatomical left plates with an incorrect thread orientation. 64 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 408
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 200 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 212 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 412 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 201 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 109 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 418 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 100 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 219 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 214 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 208 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 397
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 197 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 100 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 115 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 209 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 220 units
2025-01-21 Class II Process control Complaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices 210 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer