Rayhack

Cortical Screw

Registry build 21.09.26
22manufacturers in China registered for this device type
85catalogue numbers in this listing
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Zhejiang (3). 12 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HRS
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11
Kingj Medical Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 7
Hangzhou Sino-MIM Technology Co., Ltd. Hangzhou Zhejiang Contract manufacturer 6
Suzhou AND Science & Technology Development Corp. Zhangjiagang Jiangsu Contract manufacturer 5
Beijing AK Medical Co., Ltd. Changping District Beijing Contract manufacturer 3

Showing 12 of 22. All 22 manufacturers in China registered for Plate, Fixation, Bone

Record

Regulatory record for Rayhack
Listed by Wright Medical Technology, Inc., United States
FDA product code HRS
Device type Plate, Fixation, Bone
Device class Class 2
Regulation 21 CFR 888.3030
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2015-10-01
Record revised 2025-02-06 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number, manufacturing date
Storage Storage environment temperature 15 to 30 °C
Sizes Outer diameter 2.7 to 3.5 mm; length 10 to 24 mm
Distribution end date 2015-11-10

Catalogue Numbers

Catalogue numbers for Rayhack
Catalogue number Size Status
40100776 Outer Diameter 2.7 mm In distribution
958 Length 18 mm In distribution
988 Outer Diameter 2.7 mm In distribution
990 Outer Diameter 2.7 mm In distribution
40100916 Length 16 mm In distribution
4010982T Length 12 mm In distribution
40100772 Locking In distribution
40100211 In distribution
40100780 Outer Diameter 2.7 mm In distribution
938 Length 18 mm In distribution
40100109 In distribution
4010936T Outer Diameter 3.5 mm In distribution
4010990T Length 20 mm In distribution
40100782 Outer Diameter 2.7 mm In distribution
954 Outer Diameter 2.7 mm In distribution
950 Outer Diameter 2.7 mm In distribution
40100956 Length 16 mm In distribution
40100924 Length 24 mm In distribution
944 Outer Diameter 3.5 mm In distribution
40100774 Outer Diameter 2.7 mm In distribution
479 In distribution
4010932T Length 12 mm In distribution
40100778 Length 18 mm In distribution
40100962 Length 22 mm In distribution
4010984T Outer Diameter 2.7 mm In distribution
4010992T Length 22 mm In distribution
4010940T Length 20 mm In distribution
770 Length 10 mm In distribution
960 Outer Diameter 2.7 mm In distribution
774 Outer Diameter 2.7 mm In distribution
952 Outer Diameter 2.7 mm In distribution
778 Outer Diameter 2.7 mm In distribution
40100922 Length 22 mm In distribution
912 Outer Diameter 3.5 mm In distribution
956 Outer Diameter 2.7 mm In distribution
922 Outer Diameter 3.5 mm In distribution
211 In distribution
40100964 Outer Diameter 2.7 mm In distribution
4010938T Outer Diameter 3.5 mm In distribution
40100910 Length 10 mm In distribution
40100479 Locking In distribution
40100950 Length 10 mm In distribution
940 Length 20 mm In distribution
40100914 Outer Diameter 3.5 mm In distribution
4010994T Length 24 mm In distribution
962 Length 22 mm In distribution
910 Outer Diameter 3.5 mm In distribution
932 Outer Diameter 3.5 mm In distribution
40100912 Length 12 mm In distribution
40100770 Length 10 mm In distribution
920 Outer Diameter 3.5 mm In distribution
4010313T In distribution
930 Outer Diameter 3.5 mm In distribution
776 Outer Diameter 2.7 mm In distribution
984 Outer Diameter 2.7 mm In distribution
918 Length 18 mm In distribution
4010986T Outer Diameter 2.7 mm In distribution
40100952 Outer Diameter 2.7 mm In distribution
942 Outer Diameter 3.5 mm In distribution
4010980T Length 10 mm In distribution
40100920 Length 20 mm In distribution
4010988T Length 18 mm In distribution
924 Outer Diameter 3.5 mm In distribution
40100958 Length 18 mm In distribution
782 Outer Diameter 2.7 mm In distribution
934 Length 14 mm In distribution
772 Outer Diameter 2.7 mm In distribution
4010942T Length 22 mm In distribution
4010944T Outer Diameter 3.5 mm In distribution
986 Length 16 mm In distribution
4010211T In distribution
4010930T Length 10 mm In distribution
936 Length 16 mm In distribution
40100555 In distribution
4010934T Length 14 mm In distribution
40100954 Length 14 mm In distribution
555 In distribution
964 Outer Diameter 2.7 mm In distribution
40100918 Length 18 mm In distribution
980 Outer Diameter 2.7 mm In distribution
40100960 Length 20 mm In distribution
780 Locking In distribution
916 Outer Diameter 3.5 mm In distribution
914 Length 14 mm In distribution
109 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Pectus System Biomet Microfixation 4,662
Arthrex® Arthrex, Inc. 3,031
Evos Smith & Nephew, Inc. 2,235
Peri-Loc Smith & Nephew, Inc. 2,196
OsteoMed Osteomed 1,961
VariAx Stryker GmbH 1,934
Aptus Medartis Inc. 1,688
TC-100 Smith & Nephew, Inc. 1,639
Plate, Fixation, Bone Synthes Gmbh 1,613
Anthem Globus Medical, Inc. 1,551
Acumed Acumed LLC 1,360
Signex Osteonic Co., Ltd. 1,310

Showing 12 of 3,530. All products under Plate, Fixation, Bone

Recalls

40 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-04-10 Class II Employee error Two lots of Ortholoc 3Di Fusion plates contain incorrect dorsiflexion descriptions laser marked on the parts. 50 units
2023-04-10 Class II Employee error Two lots of Ortholoc 3Di Fusion plates contain incorrect dorsiflexion descriptions laser marked on the parts. 41 units
2023-02-02 Class II Employee error Stryker has identified an issue that impacts two specific lots of CLAW” II plates. The plates within these two lots were found to have been comingled, resulting in the incorrect product in packages. Packaging for 402S0425 incorrectly contai 10 units
2023-02-02 Class II Employee error Stryker has identified an issue that impacts two specific lots of CLAW” II plates. The plates within these two lots were found to have been comingled, resulting in the incorrect product in packages. Packaging for 402S0425 incorrectly contai 4 units
2022-02-15 Class II Process control An incorrect screw is packaged in the product, which contains a locking screw instead of a non-locking screw. 1 package 2022-10-05
2022-02-09 Class II Packaging process control Product was labelled with the incorrect manufacturing and distribution dates. 12 units 2024-01-25
2021-12-03 Class II Under Investigation by firm Incorrect product is contained in the packaging. 22 units
2021-12-03 Class II Under Investigation by firm The incorrect product is contained in the packaging. 23 units
2021-12-03 Class II Under Investigation by firm The incorrect product is contained in the packaging. 250 units
2016-11-08 Class II Process control The firm discovered a lack of adequate documentation confirming sterility on certain products. 30 units 2020-11-03
2016-11-08 Class II Process control The firm discovered a lack of adequate documentation confirming sterility on certain products. 42 units 2020-11-03
2015-07-21 Class II Employee error These screws have a potential of passing through the plate in the case when torque is applied in excessive amounts, which may result in intraoperative malfunction. 5687 units 2018-08-01
2015-07-21 Class II Employee error These screws have a potential of passing through the plate in the case when torque is applied in excessive amounts, which may result in intraoperative malfunction. 107 units 2018-08-01
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 167 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 100 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 233 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction. 52 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction. 92 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 142 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 242 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 270 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 128 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 138 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 102 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 372 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction. 51 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction. 151 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 308 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 172 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 148 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 102 units 2018-08-05
2015-03-06 Class II Nonconforming Material/Component The minor diameter, major diameter, thread pitch, and pitch on the Crosscheck are out of specification, which may result in intraoperative malfunction 301 units 2018-08-05
2014-07-30 Class II Device Design Plates manufactured from an incorrect raw material. 0 2018-06-15
2014-07-30 Class II Device Design Plates manufactured from an incorrect raw material. 50 units 2018-06-15
2014-07-30 Class II Device Design Plates manufactured from an incorrect raw material. 1127 units 2018-06-15
2014-07-30 Class II Device Design Plates manufactured from an incorrect raw material. 400 units 2018-06-15
2014-07-30 Class II Device Design Plates manufactured from an incorrect raw material. 9 units 2018-06-15
2014-07-30 Class II Device Design Plates manufactured from an incorrect raw material. 178 units 2018-06-15
2014-07-30 Class II Device Design Plates manufactured from an incorrect raw material. 18 units 2018-06-15
2014-07-30 Class II Device Design Plates manufactured from an incorrect raw material. 66 units 2018-06-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer