Rhead

Rim Plate, Standard, Long, Fix. Angle Locking

Registry build 21.09.26
22manufacturers in China registered for this device type
64catalogue numbers in this listing
25510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Zhejiang (3). 12 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HRS
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11
Kingj Medical Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 7
Hangzhou Sino-MIM Technology Co., Ltd. Hangzhou Zhejiang Contract manufacturer 6
Suzhou AND Science & Technology Development Corp. Zhangjiagang Jiangsu Contract manufacturer 5
Beijing AK Medical Co., Ltd. Changping District Beijing Contract manufacturer 3

Showing 12 of 22. All 22 manufacturers in China registered for Plate, Fixation, Bone

Record

Regulatory record for Rhead
Listed by Stryker GmbH, Switzerland
FDA product code HRS
Device type Plate, Fixation, Bone
Device class Class 2
Regulation 21 CFR 888.3030
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
Record published 2015-09-24
Record revised 2025-04-14 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Sizes Length 6 to 40 mm
Distribution end date 2022-11-01

Catalogue Numbers

Catalogue numbers for Rhead
Catalogue number Size Status
173-2418 Diameter: 2.4 Millimeter In distribution
173-2710 Diameter: 2.7 Millimeter In distribution
171-2408 Diameter: 2.4 Millimeter In distribution
171-2708 Diameter: 2.7 Millimeter In distribution
173-2716 Length 16.0 mm In distribution
173-2408 Length 8.0 mm In distribution
173-2426 Length 26.0 mm In distribution
171-2726 Length 26.0 mm In distribution
171-2414 Length 14.0 mm In distribution
173-2726 Diameter: 2.7 Millimeter In distribution
173-2720 Diameter: 2.7 Millimeter In distribution
173-2428 Length 28.0 mm In distribution
173-2414 Diameter: 2.4 Millimeter In distribution
171-2716 Length 16.0 mm In distribution
171-2426 Diameter: 2.4 Millimeter In distribution
173-2718 Length 18.0 mm In distribution
173-2724 Length 24.0 mm In distribution
171-2410 Diameter: 2.4 Millimeter In distribution
171-2724 Diameter: 2.7 Millimeter In distribution
173-2422 Length 22.0 mm In distribution
103-0303 In distribution
173-2712 Length 12.0 mm In distribution
173-2728 Length 28.0 mm In distribution
171-2718 Length 18.0 mm In distribution
173-2420 Length 20.0 mm In distribution
171-2720 Length 20.0 mm In distribution
171-2424 Length 24.0 mm In distribution
171-2722 Diameter: 2.7 Millimeter In distribution
171-2412 Length 12.0 mm In distribution
171-2710 Diameter: 2.7 Millimeter In distribution
103-0300 In distribution
171-2418 Length 18.0 mm In distribution
173-2722 Length 22.0 mm In distribution
171-2416 Length 16.0 mm In distribution
171-2714 Diameter: 2.7 Millimeter In distribution
171-2422 Length 22.0 mm In distribution
173-2714 Length 14.0 mm In distribution
103-0302 In distribution
171-2428 Diameter: 2.4 Millimeter In distribution
173-2412 Diameter: 2.4 Millimeter In distribution
173-2708 Diameter: 2.7 Millimeter In distribution
173-2410 Diameter: 2.4 Millimeter In distribution
171-2712 Length 12.0 mm In distribution
173-2424 Length 24.0 mm In distribution
173-2416 Diameter: 2.4 Millimeter In distribution
103-0102 In distribution
171-2420 Length 20.0 mm In distribution
171-2728 Length 28.0 mm In distribution
171-2040 Length 40.0 mm Withdrawn
171-2026 Diameter: 2.0 Millimeter Withdrawn
171-2018 Diameter: 2.0 Millimeter Withdrawn
171-2020 Length 20.0 mm Withdrawn
171-2024 Length 24.0 mm Withdrawn
171-2038 Length 38.0 mm Withdrawn
171-2032 Diameter: 2.0 Millimeter Withdrawn
171-2730 Length 30.0 mm Withdrawn
171-2028 Length 28.0 mm Withdrawn
171-2030 Diameter: 2.0 Millimeter Withdrawn
171-2406 Length 6.0 mm Withdrawn
171-2706 Length 6.0 mm Withdrawn
171-2430 Diameter: 2.4 Millimeter Withdrawn
171-2036 Diameter: 2.0 Millimeter Withdrawn
171-2022 Diameter: 2.0 Millimeter Withdrawn
171-2034 Diameter: 2.0 Millimeter Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Pectus System Biomet Microfixation 4,662
Arthrex® Arthrex, Inc. 3,031
Evos Smith & Nephew, Inc. 2,235
Peri-Loc Smith & Nephew, Inc. 2,196
OsteoMed Osteomed 1,961
VariAx Stryker GmbH 1,934
Aptus Medartis Inc. 1,688
TC-100 Smith & Nephew, Inc. 1,639
Plate, Fixation, Bone Synthes Gmbh 1,613
Anthem Globus Medical, Inc. 1,551
Acumed Acumed LLC 1,360
Signex Osteonic Co., Ltd. 1,310

Showing 12 of 3,530. All products under Plate, Fixation, Bone

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K242445 2024-10-06
K233919 2024-03-25
K231257 2023-08-18
K231262 2023-08-18
K222381 2023-04-27
K223772 2023-04-07
K221346 2022-07-08
K212581 2022-01-19
K200398 2020-06-05
K192675 2019-11-22
K191412 2019-08-23
K183172 2019-03-05
K181091 2018-10-11
K172148 2018-03-19
K172350 2017-12-15
K170727 2017-06-22
K170771 2017-05-08
K162841 2017-02-21
K162439 2017-02-03
K153379 2016-05-26
K151769 2015-10-27
K151879 2015-08-06
K113109 2011-12-23
K112926 2011-12-19
K110476 2011-03-18

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-12-05 Class II Under Investigation by firm Instrument can break at the level of the thread when being exposed to high forces during nail implantation or removal which can lead to complications during nail insertion and removal. 433 (289 units U.S. / 144 units OUS) 2020-10-09

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer