Comprehensive® Shoulder System

85 catalogue numbers from 113648, listed by Biomet Orthopedics, United States, under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
85catalogue numbers in this listing
1510(k) clearance

Who Else Makes It

Concentrated in Shanghai (3), Jiangsu (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSD
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Comprehensive® Shoulder System
Listed by Biomet Orthopedics, United States
FDA product code HSD
Device type Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
Device class Class 2
Regulation 21 CFR 888.3690
510(k) K060692
Record published 2019-08-30
Record revised 2025-10-31 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Comprehensive® Shoulder System
Catalogue number Size Status
113648 8 mm 122mm Long In distribution
407024 6 mm / 7 mm In distribution
407318 In distribution
110004319 In distribution
407346 6 mm In distribution
TI-113042 46MM HEAD Ø 18MM HEIGHT 53MM Ø OF CURV In distribution
113651 11 mm 122mm Long In distribution
11-113564 14 MM 122MM LONG In distribution
407319 19 mm In distribution
407315 15 mm In distribution
41-405814 14 mm In distribution
407325 5 mm In distribution
113134 42MM HEAD Ø 21MM HEIGHT 43MM Ø OF CURV In distribution
41-405810 10 mm In distribution
407330 10MM In distribution
113626 6 MM 83MM LONG In distribution
407028 10 mm / 11 mm In distribution
113610 10 MM 55MM LONG In distribution
31-406914 14 mm In distribution
TI-113046 46MM HEAD Ø 24MM HEIGHT 47MM Ø OF CURV In distribution
407304 4 mm In distribution
TI-113057 50MM HEAD Ø 27MM HEIGHT 50MM Ø OF CURV In distribution
407008 10 mm In distribution
407327 7MM In distribution
113648 8 MM 122MM LONG In distribution
113612 12 MM 55MM LONG In distribution
113644 4 mm 122mm Long In distribution
113611 11 mm 55mm Long In distribution
113635 15 mm 83mm Long In distribution
405308 8 mm In distribution
31-406914 In distribution
407324 4 mm In distribution
407320 In distribution
113632 12 mm 83mm Long In distribution
407332 12 mm In distribution
407316 16 mm In distribution
113639 19 MM 83MM LONG In distribution
113612 12 mm 55mm Long In distribution
113607 7 MM 55MM LONG In distribution
31-406910 In distribution
407015 17 mm In distribution
407313 13 mm In distribution
407326 6MM In distribution
113651 11 MM 122MM LONG In distribution
407333 13 mm In distribution
407013 15 mm In distribution
113652 12 MM 122MM LONG In distribution
407354 In distribution
407336 16 mm Standard In distribution
407010 12MM In distribution
113346 46MM HEAD Ø 24MM HEIGHT 47MM Ø OF CURV In distribution
12-113556 6 MM 122MM LONG In distribution
113609 9 MM 55MM LONG In distribution
407015 17MM In distribution
113615 15 MM 55MM LONG In distribution
113632 12 MM 83MM LONG In distribution
31-406906 In distribution
113645 5 MM 122MM LONG In distribution
113653 13 MM 122MM LONG In distribution
407005 7MM In distribution
113344 46MM HEAD Ø 21MM HEIGHT 50MM Ø OF CURV In distribution
113656 16 mm 122mm Long In distribution
113633 13 MM 83MM LONG In distribution
407004 6MM In distribution
113639 19 mm 83mm Long In distribution
407024 In distribution
407011 In distribution
407334 14 mm In distribution
113654 14 mm 122mm Long In distribution
113067 54MM HEAD Ø 27MM HEIGHT 55MM Ø OF CURV In distribution
405315 15 mm In distribution
405316 16 mm In distribution
12-113558 8 MM 122MM LONG In distribution
407010 12 mm In distribution
407308 In distribution
41-405815 15 mm In distribution
113654 14 MM 122MM LONG In distribution
113613 13 mm 55mm Long In distribution
113625 5 MM 83MM LONG In distribution
11-113560 10 MM 122MM LONG In distribution
407307 7 mm In distribution
113630 10 MM 83MM LONG In distribution
407350 In distribution
407319 In distribution
113046 46MM HEAD Ø 24MM HEIGHT 47MM Ø OF CURV In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 345
SMR Shoulder Limacorporate 182
FX V135 Fx Shoulder Solutions SAS 127
Acumed Acumed LLC 112
Promos Smith & Nephew, Inc. 104
Trabecular Metal® Zimmer, Inc. 90
Bigliani/Flatow® Zimmer, Inc. 86
Arthrex® Arthrex, Inc. 75
SMR System Limacorporate 72
DJO Surgical Encore Medical, L.P. 70
Humeris Shoulder Fx Solutions 69
Prima Limacorporate 67

Showing 12 of 241. All products under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K010827 2001-09-14

Recalls Naming This Product

28 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Comprehensive® Shoulder System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer Orthopedics Manufacturing Limited-Galway 510(k) number 2025-03-03 Class II Nonconforming Material/Component Five complaints received where surgeon was unable to remove and/or connect the inserter with the stem during surgery due to excess material remaining within the taper. Issue may lead to clinically significant extension of surgery to find a 90 US; 136 OUS
Biomet, Inc. UDI-DI 2022-01-07 Class II Process control The products in scope underwent an incorrect rework operation for the porous plasma sprayed coating. Internal testing indicated that the parts may not have sufficient adhesion strength. The scope was identified to be all lots that were poro 12 units 2023-04-13
Biomet, Inc. UDI-DI 2022-01-07 Class II Process control The products in scope underwent an incorrect rework operation for the porous plasma sprayed coating. Internal testing indicated that the parts may not have sufficient adhesion strength. The scope was identified to be all lots that were poro 9 units 2023-04-13
Biomet, Inc. 510(k) number 2020-02-17 Class II Under Investigation by firm A 15mm Shoulder Mini Humeral Stem was misidentified as a 9mm Shoulder Mini Humeral Stem. 14 units 2022-05-31
Biomet, Inc. 510(k) number 2018-10-10 Class II Under Investigation by firm Zimmer Biomet is conducting a lot specific medical device recall for two lots of the Orthopedic Salvage System (OSS) and the Comprehensive Shoulder System. The investigation determined that the Mini Humeral Stem is potentially labeled as th 3 total 2020-04-28
Biomet, Inc. 510(k) number 2017-12-08 Class II Under Investigation by firm Zimmer Biomet is conducting a medical device recall for two lots of Comprehensive Humeral stems. The lots were commingled during the manufacturing process and were etched with incorrect lot numbers. The size difference between the two stem 12 2018-09-04
Biomet, Inc. 510(k) number 2017-12-08 Class II Under Investigation by firm Zimmer Biomet is conducting a medical device recall for two lots of Comprehensive Humeral stems. The lots were commingled during the manufacturing process and were etched with incorrect lot numbers. The size difference between the two stem 12 2018-09-04
Biomet, Inc. 510(k) number 2017-06-05 Class II Labeling False and Misleading Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect. 2018-03-06
Biomet, Inc. 510(k) number 2017-06-05 Class II Labeling False and Misleading Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect. 2018-03-06
Biomet, Inc. 510(k) number 2017-04-26 Class II Under Investigation by firm Zimmer Biomet is conducting a voluntary recall for a single lot of the Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System after it was determined that two pieces from the lot were moved to finished goods and shipped des 16 2018-03-30
Biomet, Inc. 510(k) number 2017-02-17 Class II Process design Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components. 28,253 in total 2018-01-29
Biomet, Inc. 510(k) number 2016-12-20 Class I Device Design Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing. 4388 2017-08-29
Biomet, Inc. 510(k) number 2015-04-16 Class III Labeling mix-ups Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes. 2 2016-05-16
Biomet, Inc. 510(k) number 2013-05-15 Class II Device Design Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction.
When the slot on the resection guide is offset in the wrong direction, the Steinman pin that
17 2014-06-09
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1,575 units all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1,575 units all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 units all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products. 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1,575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2010-09-13 Not classified Pending The firm received complaints regarding fracturing of the device. 45 both products 2011-07-27
Biomet, Inc. 510(k) number 2010-09-13 Not classified Pending The firm received complaints regarding fracturing of the device. 45 both products 2011-07-27
Biomet, Inc. 510(k) number 2008-03-13 Not classified Device Design The glenoid implant may not seat fully on the face of the natural glenoid due to inadequate measurement tolerances (tolerance stack-up) in the design of the cutter. Use of the instrument may lead to incomplete seating of the glenoid implan 189 2008-10-15
Biomet, Inc. 510(k) number 0012-12-06 Class II Nonconforming Material/Component Biomet is recalling Part Number PT-113950 PT Hybrid Glenoid Post, following an investigation which identified that the male thread of the post may be oversized. This oversized condition can vary in degree and may lead to the following thre 1050 2013-11-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer