Trabecular Metal®

90 catalogue numbers from 00-4349-012-13, listed by Zimmer, Inc., United States, under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
90catalogue numbers in this listing
1510(k) clearance
3recalls on this code

Who Else Makes It

Concentrated in Shanghai (3), Jiangsu (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSD
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Trabecular Metal®
Listed by Zimmer, Inc., United States
FDA product code HSD
Device type Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
Device class Class 2
Regulation 21 CFR 888.3690
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K052906
Record published 2015-09-17
Record revised 2023-05-03 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Sizes Length 15 to 200 mm; height 15 to 21 mm

Catalogue Numbers

Catalogue numbers for Trabecular Metal®
Catalogue number Size Status
00-4349-012-13 12 mm Stem Diameter, 130 mm Stem Length In distribution
4342-106-13 6 mm Stem Diameter, 130 mm Stem Length, 42, Degrees In distribution
00-4309-036-00 Plus 0 mm Offset, 36 mm Diameter In distribution
4342-112-17 12 mm Stem Diameter, 170 mm Stem Length, 42, Degrees In distribution
00-4312-014-17 14 mm Diameter In distribution
4309-51-18 Height 18 mm In distribution
4342-111-13 11 mm Stem Diameter, 130 mm Stem Length, 42, Degrees In distribution
00-4309-045-20 7.5 mm Diameter In distribution
00-4309-065-03 Plus (+) 3 mm Offset, 36 mm Diameter, 65 Degree Neck Angle In distribution
00-4309-047-15 Length 15 mm In distribution
00-4350-017-13 17 mm, Stem, Diameter In distribution
00-4350-014-20 14 mm Stem Diameter, 200 mm Stem Length In distribution
00-4309-028-00 40 mm In distribution
00-4309-021-14 14 mm In distribution
4309-52-18 Height 18 mm In distribution
4309-18-10 48 Degrees, 9/10 mm Diameter In distribution
4309-17 In distribution
00-4312-008-02 Length 200 mm In distribution
00-4349-020-00 20 mm Post Length In distribution
4348-114-13 14 mm Stem Diameter, 130 mm Stem Length, 48, Degrees In distribution
00-4349-040-03 Plus 3 mm Offset, 40 mm, Diameter In distribution
00-4349-040-06 Plus 6 mm Offset, 40 mm, Diameter In distribution
4309-01-16 16 mm Diameter In distribution
4342-115-13 15 mm Stem Diameter, 130 mm Stem Length, 42, Degrees In distribution
00-4312-007-00 7 mm Diameter In distribution
00-4349-010-13 10 mm Stem Diameter, 130 mm Stem Length In distribution
4342-110-13 10 mm Stem Diameter, 130 mm Stem Length, 42, Degrees In distribution
00-4309-040-03 Plus 3 mm Offset, 40 mm Diameter In distribution
00-4312-008-17 Length 170 mm In distribution
00-4349-066-03 Plus 3 mm Offset, 65 Degree Neck Angle, 40 mm, Diameter In distribution
4309-52-15 Height 15 mm In distribution
4309-06 48 Degrees In distribution
00-4309-040-01 40 mm Diameter In distribution
4348-111-13 11 mm Stem Diameter, 130 mm Stem Length, 48, Degrees In distribution
00-4309-066-00 Plus (+) 0 mm Offset, 40 mm Diameter, 65 Degree Neck Angle In distribution
00-4312-018-02 18 mm Diameter In distribution
00-4312-018-00 18 mm Diameter In distribution
00-4312-009-02 9 mm Diameter In distribution
00-4309-045-02 7.5 mm Diameter In distribution
4348-110-13 10 mm Stem Diameter, 130 mm Stem Length, 48, Degrees In distribution
00-4309-021-18 18 mm Diameter In distribution
00-4350-015-13 15 mm Stem Diameter, 130 mm Stem Length In distribution
4342-110-17 10 mm Stem Diameter, 170 mm Stem Length, 42, Degrees In distribution
00-4312-013-13 Length 130 mm In distribution
00-4309-045-30 Length 30 mm In distribution
4309-01 42 Degrees In distribution
00-4309-026-00 In distribution
4348-113-13 13 mm Stem Diameter, 130 mm Stem Length, 48, Degrees In distribution
4342-116-13 16 mm Stem Diameter, 130 mm Stem Length, 42, Degrees In distribution
4309-12-06 Length 130 mm In distribution
00-4349-020-02 20 mm Post Length, +2 mm Lateral Offset In distribution
47-4309-046-01 2.5 mm Diameter In distribution
00-4309-023-10 10 mm In distribution
00-4312-006-00 6 mm Diameter In distribution
00-4349-066-00 Plus 0 mm Offset, 65 Degree Neck Angle, 40 mm, Diameter In distribution
00-4309-047-00 In distribution
00-4312-008-20 8 mm Diameter In distribution
47-4309-061-30 Length 30 mm In distribution
00-4349-039-12 Size 12 mm In distribution
00-4312-015-02 Length 200 mm In distribution
4348-115-13 15 mm Stem Diameter, 130 mm Stem Length, 48, Degrees In distribution
00-4312-019-02 Length 200 mm In distribution
00-4349-065-06 Plus 6 mm Offset, 65 Degree Neck Angle, 36 mm, Diameter In distribution
00-4349-012-17 12 mm Stem Diameter, 170 mm Stem Length In distribution
00-4350-012-13 12 mm Stem Diameter, 130 mm Stem Length In distribution
4348-109-13 9 mm Stem Diameter, 130 mm Stem Length, 48, Degrees In distribution
00-4312-014-20 Length 200 mm In distribution
00-4312-009-13 Length 130 mm In distribution
00-4309-029-02 In distribution
4309-51-15 Height 15 mm In distribution
4309-18-06 Length 130 mm In distribution
00-4312-010-20 10 mm Diameter In distribution
00-4309-042-01 40 mm In distribution
00-4350-018-20 18 mm, Stem, Diameter In distribution
4309-18-16 48 Degrees, 15/16 mm Diameter In distribution
00-4312-010-13 10 mm Diameter In distribution
00-4349-040-03 Plus 3 mm Offset, 40 mm, Diameter In distribution
00-4312-016-20 Length 200 mm In distribution
00-4309-023-14 14 mm In distribution
4309-51-21 Height 21 mm In distribution
00-4349-016-13 16 mm Stem Diameter, 130 mm Stem Length In distribution
00-4349-040-00 Plus 0 mm Offset, 40 mm, Diameter In distribution
4342-108-13 8 mm Stem Diameter, 130 mm Stem Length, 42, Degrees In distribution
00-4349-037-00 In distribution
00-4350-006-13 6 mm Stem Diameter, 130 mm Stem Length In distribution
00-4309-036-03 Plus 3 mm Offset, 36 mm Diameter In distribution
00-4349-015-00 15 mm Post Length In distribution
00-4349-025-02 25 mm Post Length, +2 mm Lateral Offset In distribution
4309-02 48 Degrees In distribution
00-4349-036-00 Plus 0 mm Offset, 36 mm, Diameter In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 345
SMR Shoulder Limacorporate 182
FX V135 Fx Shoulder Solutions SAS 127
Acumed Acumed LLC 112
Promos Smith & Nephew, Inc. 104
Bigliani/Flatow® Zimmer, Inc. 86
Comprehensive® Shoulder System Biomet Orthopedics 85
Arthrex® Arthrex, Inc. 75
SMR System Limacorporate 72
DJO Surgical Encore Medical, L.P. 70
Humeris Shoulder Fx Solutions 69
Prima Limacorporate 67

Showing 12 of 241. All products under Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K161620 2016-11-01

Recalls Naming This Product

18 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Trabecular Metal®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2019-10-10 Class II Packaging change control Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). 5,459,583 total devices 2020-05-19
Zimmer, Inc. 510(k) number 2017-05-22 Class II Process control Various trauma and extremity instruments (drill bits and screw taps) were manufactured from raw material with an anomaly. The anomaly may be on or below the surface and can increase the risk of instrument fracture. 2825 units 2019-03-29
Zimmer, Inc. 510(k) number 2014-01-10 Class II Nonconforming Material/Component This single manufacturing lot has the potential for the bond strength between the Trabecular Metal material and substrate to be below the minimum required specification. Testing found bond strength approximately 80% of the minimum required 10 units 2014-09-11
Zimmer, Inc. 510(k) number 2013-12-10 Class II Labeling mix-ups Zimmer is initiating a lot specific recall of the CPT Hip Stem, Versys Build-Up Block, and Trabecular Metal Reverse Glenosphere medical devices due to reports of the products being packaged in the incorrect outer carton. Product labels and 25 2014-09-11
Zimmer, Inc. 510(k) number 2013-10-17 Class II Device Design As a result of complaints for disassociation of the TM Reverse Glenosphere from the Baseplate, Zimmer updated the related surgical technique and released a video to provide additional instructions to users on how to properly assemble the Gl 73,002 units 2014-09-12
Zimmer, Inc. 510(k) number 2013-08-01 Class II Device Design Zimmer is initiating a lot specific recall of the Trabecular Metal” Reverse Glenosphere Distractor due to the potential of the device not functioning properly should it be utilized without proper lubrication. As a result, there is a potenti 771 2015-03-02
Zimmer, Inc. 510(k) number 2013-06-11 Class II Packaging process control The firm is initiating a removal of one lot of the Bigliani/Flatow Humeral Provisional Stem (00-4301-012-17, lot 62283991) as the stems manufactured under the lot are 14mm x 170mm devices incorrectly etched and packaged as 12mm x 170mm devi 1 2014-01-30
Zimmer, Inc. 510(k) number 2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 9,790 total distal pilots in distribution. 2012-09-14
Zimmer, Inc. 510(k) number 2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 9,790 total distal pilots in distribution. 2012-09-14
Zimmer, Inc. 510(k) number 2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 13,093 total reamers in distribution. 2012-09-14
Zimmer, Inc. 510(k) number 2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 2012-09-14
Zimmer, Inc. 510(k) number 2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 2012-09-14
Zimmer, Inc. 510(k) number 2010-09-10 Not classified Device Design The results of an investigation into complaints revealed that Trabecular Metal Humeral and/or Zimmer Trabecular Metal Reverse Humeral implants engaging in the canal earlier than expected could lead to incomplete seating of the implant, dela 2012-09-14
Zimmer, Inc. 510(k) number 2009-09-17 Not classified Other Some of the devices may possess a taper which will not mate with the humeral head, as intended. 12 2009-12-22
Zimmer, Inc. 510(k) number 2009-09-17 Not classified Other Some of the devices may possess a taper which will not mate with the humeral head, as intended. 12 2009-12-22
Zimmer, Inc. 510(k) number 2006-07-20 Not classified Other Components may not lock together as intended. 197 for all three recalls Z-1416-1418-06 2007-12-19
Zimmer, Inc. 510(k) number 2006-07-20 Not classified Other Components may not lock together as intended. 197 for all three recalls Z-1416-1418-06 2007-12-19
Zimmer, Inc. 510(k) number 2006-07-20 Not classified Other Components may not lock together as intended. 197 for all three recalls Z-1416-1418-06 2007-12-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer