Iuni® Femoral Kit

2 catalogue numbers from RUK101111203, listed by ConforMIS, Inc., United States, under Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer. 6 manufacturers in China are registered for this product code.

Registry build 21.09.26
6manufacturers in China registered for this device type
2catalogue numbers in this listing
8510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Zhejiang (2), Jiangsu (2), Shanghai (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSX
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Turnxon Precision Co., Ltd. Dongguan Guangdong Contract manufacturer 17
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74

Record

Regulatory record for iUni® Femoral Kit
Listed by ConforMIS, Inc., United States
FDA product code HSX
Device type Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3520
Establishment Remanufacturer, Reprocessor, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K132640
Record published 2015-10-26
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries expiry date, serial number

Catalogue Numbers

Catalogue numbers for iUni® Femoral Kit
Catalogue number Size Status
RUK101111203 Patient Specific In distribution
RUK101111202 Patient Specific In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Journey Smith & Nephew, Inc. 517
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer Ortho Development Corp. 303
BKS® Uni Ortho Development Corp. 240
LinkSymphoKnee Waldemar Link GmbH & Co. KG 210
Moto Partial Knee System Medacta International SA 205
Arthrex® Arthrex, Inc. 199
Stride Smith & Nephew, Inc. 190
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer Zimmer, Inc. 175
ZUK Smith & Nephew, Inc. 161
Tahoe Uni Knee System Shalby Advanced Technologies, Inc. 134
Moto Partial Knee System – Medial Medacta International SA 132
Journey II Smith & Nephew, Inc. 119

Showing 12 of 171. All products under Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K132640 2013-12-05
K121974 2012-09-06
K111916 2011-09-29
K092441 2009-09-09
K072586 2007-11-08
K072368 2007-09-20
K063432 2007-03-16
K043570 2005-03-14

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of iUni® Femoral Kit
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
ConforMIS, Inc. 510(k) number 2015-08-31 Class II Process design May contain small amounts of ethylene glycol residue 7 units 2016-03-02
ConforMIS, Inc. 510(k) number 2015-08-31 Class II Process design May contain small amounts of ethylene glycol residue 71 units 2016-03-02
ConforMIS, Inc. 510(k) number 2015-08-31 Class II Process design May contain small amounts of ethylene glycol residue 6 units 2016-03-02

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2009-04-23 Not classified Process control Microscopic cracks potential for pre-mature revisions in patients implanted with the system. 6 units 2009-10-14
2009-04-23 Not classified Process control Microscopic cracks potential for pre-mature revisions in patients implanted with the system. 1 unit 2009-10-14
2009-04-23 Not classified Process control Microscopic cracks potential for pre-mature revisions in patients implanted with the system. 10 Units 2009-10-14

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer