NexGen®

26 catalogue numbers from 5988-04-20, listed by Zimmer, Inc., United States, under Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer. 6 manufacturers in China are registered for this product code.

Registry build 21.09.26
6manufacturers in China registered for this device type
26catalogue numbers in this listing
9510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Zhejiang (2), Jiangsu (2), Shanghai (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSX
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Turnxon Precision Co., Ltd. Dongguan Guangdong Contract manufacturer 17
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74

Record

Regulatory record for NexGen®
Listed by Zimmer, Inc., United States
FDA product code HSX
Device type Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3520
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K152494
Record published 2015-09-17
Record revised 2023-02-03 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for NexGen®
Catalogue number Size Status
5988-04-20 Size 4, 16 Degrees In distribution
5988-07-26 Size 7, 5 mm Thickness In distribution
5988-08-27 Size 8, 10 mm Thickness In distribution
5988-05-23 Size 5, 7 Degrees In distribution
5988-02-21 Size 2, 26 Degrees In distribution
5988-08-22 Size 8, 22 Degrees In distribution
5988-02-26 Size 2, 5 mm Thickness In distribution
5988-02-27 Size 2, 10 mm Thickness In distribution
5990-36-01 Size F, 5 mm Augment In distribution
5988-04-22 Size 4, 22 Degrees In distribution
5988-03-22 Size 3, 22 Degrees In distribution
5988-07-22 Size 7, 22 Degrees In distribution
5988-02-20 Size 2, 16 Degrees In distribution
5988-03-23 Size 3, 7 Degrees In distribution
5988-05-21 Size 5, 26 Degrees In distribution
5988-06-21 Size 6, 26 Degrees In distribution
5990-36-10 Size F, 5 mm Augment In distribution
5990-36-20 Size F, 10 mm Augment In distribution
5988-04-26 Size 4, 5 mm Thickness In distribution
5988-08-20 Size 8, 16 Degrees In distribution
5988-02-23 Size 2, 7 Degrees In distribution
5988-06-27 Size 6, 10 mm Thickness In distribution
5988-08-23 Size 8, 7 Degrees In distribution
5988-04-23 Size 4, 7 Degrees In distribution
5988-07-20 Size 7, 16 Degrees In distribution
5988-08-21 Size 8, 26 Degrees In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Journey Smith & Nephew, Inc. 517
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer Ortho Development Corp. 303
BKS® Uni Ortho Development Corp. 240
LinkSymphoKnee Waldemar Link GmbH & Co. KG 210
Moto Partial Knee System Medacta International SA 205
Arthrex® Arthrex, Inc. 199
Stride Smith & Nephew, Inc. 190
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer Zimmer, Inc. 175
ZUK Smith & Nephew, Inc. 161
Tahoe Uni Knee System Shalby Advanced Technologies, Inc. 134
Moto Partial Knee System – Medial Medacta International SA 132
Journey II Smith & Nephew, Inc. 119

Showing 12 of 171. All products under Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K200151 2020-03-17
K122529 2012-11-16
K033363 2004-01-16
K010685 2001-04-02
K952068 1995-09-19
K942263 1995-07-11
K880155 1988-08-03
K862632 1987-03-25
K803235 1981-02-04

Recalls Naming This Product

20 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of NexGen®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2025-01-06 Class II Process change control It was identified internally that two commingle events occurred where the metal support post within the polyethylene articular surface was assembled incorrectly for three units within the scope. 155 units
Zimmer, Inc. 510(k) number 2025-01-06 Class II Process change control It was identified internally that two commingle events occurred where the metal support post within the polyethylene articular surface was assembled incorrectly for three units within the scope. 155 units
Zimmer, Inc. 510(k) number 2023-05-19 Class II Under Investigation by firm Device outer packaging was incorrectly labeled. 2026-05-29
Zimmer, Inc. 510(k) number 2019-10-10 Class II Packaging change control Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). 5,459,583 total devices 2020-05-19
Zimmer, Inc. 510(k) number 2018-10-31 Class II Process control Screw is missing from the package 19 units 2019-04-08
Zimmer, Inc. 510(k) number 2017-11-29 Class II Packaging The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag. 13,227 in total 2020-04-02
Zimmer, Inc. 510(k) number 2017-11-29 Class II Packaging The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag. 13,227 in total 2020-04-02
Zimmer, Inc. 510(k) number 2016-01-11 Class II Process control LDPE bag containing the implant adheres to the highly polished implant surface. 88389 2017-05-23
Zimmer Manufacturing B.V. 510(k) number 2016-01-11 Class II Packaging As a result of the insufficient sealer calibration data for product packaged in firm’s Building II between August 2010 and April 2013. The affected products are sterile. 0 2017-04-13
Zimmer, Inc. 510(k) number 2015-04-02 Class II Mixed-up of materials/components The affected lot is being recalled because it was packaged without the locking screw. The locking screw packaged with the augment is used to fix the augment to the femoral component. This has the potential to delay surgery 20 units 2015-09-23
Zimmer, Inc. 510(k) number 2010-09-15 Not classified Process design These lots of Zimmer NexGen Complete Knee Solution LPS Femoral Component and Zimmer NexGen Complete Knee Solution LPS Flex Gender Femoral Component exhibit a nonconforming internal CAM radius. The condition is intermittent and not all dev 192 all sizes of 5996 products 2011-07-27
Zimmer, Inc. 510(k) number 2010-09-15 Not classified Process design These lots of Zimmer NexGen Complete Knee Solution LPS Femoral Component and Zimmer NexGen Complete Knee Solution LPS Flex Gender Femoral Component exhibit a nonconforming internal CAM radius. The condition is intermittent and not all dev 192 all sizes of 5996 2011-07-27
Zimmer, Inc. 510(k) number 2010-09-15 Not classified Process design These lots of Zimmer NexGen Complete Knee Solution LPS Femoral Component and Zimmer NexGen Complete Knee Solution LPS Flex Gender Femoral Component exhibit a nonconforming internal CAM radius. The condition is intermittent and not all dev 192 all sizes of 5996 2011-07-27
Zimmer, Inc. 510(k) number 2010-09-15 Not classified Process design These lots of Zimmer NexGen Complete Knee Solution LPS Femoral Component and Zimmer NexGen Complete Knee Solution LPS Flex Gender Femoral Component exhibit a nonconforming internal CAM radius. The condition is intermittent and not all dev 192 all sizes of 5996. 2011-07-27
Zimmer, Inc. 510(k) number 2010-09-15 Not classified Process design These lots of Zimmer NexGen Complete Knee Solution LPS Femoral Component and Zimmer NexGen Complete Knee Solution LPS Flex Gender Femoral Component exhibit a nonconforming internal CAM radius. The condition is intermittent and not all dev 192 all sizes of 5996. 2011-07-27
Zimmer, Inc. 510(k) number 2010-09-15 Not classified Process design These lots of Zimmer NexGen Complete Knee Solution LPS Femoral Component and Zimmer NexGen Complete Knee Solution LPS Flex Gender Femoral Component exhibit a nonconforming internal CAM radius. The condition is intermittent and not all dev 158 all sizes of 5764 2011-07-27
Zimmer, Inc. 510(k) number 2010-09-15 Not classified Process design These lots of Zimmer NexGen Complete Knee Solution LPS Femoral Component and Zimmer NexGen Complete Knee Solution LPS Flex Gender Femoral Component exhibit a nonconforming internal CAM radius. The condition is intermittent and not all dev 158 all sizes of 5764 2011-07-27
Zimmer, Inc. 510(k) number 2010-09-15 Not classified Process design These lots of Zimmer NexGen Complete Knee Solution LPS Femoral Component and Zimmer NexGen Complete Knee Solution LPS Flex Gender Femoral Component exhibit a nonconforming internal CAM radius. The condition is intermittent and not all dev 158 all sizes of 5764 2011-07-27
Zimmer, Inc. 510(k) number 2010-09-15 Not classified Process design These lots of Zimmer NexGen Complete Knee Solution LPS Femoral Component and Zimmer NexGen Complete Knee Solution LPS Flex Gender Femoral Component exhibit a nonconforming internal CAM radius. The condition is intermittent and not all dev 158 all sizes of 5764 2011-07-27
Zimmer, Inc. 510(k) number 2009-02-26 Not classified Process control Smaller diameter screws than required were included in the package. 13 2011-02-28

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-11-29 Class II Packaging The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag. 13,227 in total 2020-04-02
2017-11-29 Class II Packaging The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag. 13,227 in total 2020-04-02
2016-01-11 Class II Process control LDPE bag containing the implant adheres to the highly polished implant surface. 32537 2017-05-23
2013-08-30 Class II Package design/selection The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices. 32537 2014-09-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer