3.0mm X 20mm Gridlock Screw

Catalogue number 301-30-020, listed by Trilliant Surgical LLC, United States, under Screw, Fixation, Bone. 31 manufacturers in China are registered for this product code.

Registry build 21.09.26
31manufacturers in China registered for this device type
1catalogue number
7510(k) clearances naming this product code
15recalls on this code

Who Else Makes It

Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HWC
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11

Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone

Record

Regulatory record for 3.0mm x 20mm Gridlock Screw
Listed by Trilliant Surgical LLC, United States
FDA product code HWC
Device type Screw, Fixation, Bone
Device class Class 2
Regulation 21 CFR 888.3040
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K130964
Record published 2017-02-15
Record revised 2024-02-19 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Sizes Outer diameter 3 mm; length 20 mm

Catalogue Numbers

Catalogue numbers for 3.0mm x 20mm Gridlock Screw
Catalogue number Size Status
301-30-020 Outer Diameter 3.0 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Screw, Fixation, Bone Synthes Gmbh 3,975
Aptus Medartis Inc. 3,623
Acumed Acumed LLC 3,187
Arthrex® Arthrex, Inc. 2,781
OsteoMed Osteomed 2,764
Screw, Fixation, Bone AAP Implantate AG 2,176
Screw, Fixation, Bone Zimmer, Inc. 1,993
Arix System Bone Screw Jeil Medical Corporation 1,875
Cannulated Screw System + Tyber Medical 1,814
Cannulated Compression Headless Screw Tyber Medical 1,621
Microware Bone Plates and Bone Screws Microware Precision Co., Ltd. 1,601
Anthem Globus Medical, Inc. 1,538

Showing 12 of 5,775. All products under Screw, Fixation, Bone

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K181898 2018-10-26
K153338 2016-01-14
K122959 2012-11-07
K111834 2011-12-06
K112737 2011-10-20
K103183 2011-02-08
K081510 2008-08-04

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of 3.0mm x 20mm Gridlock Screw
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Trilliant Surgical LLC 510(k) number 2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 8 systems

Recalls

13 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 3 systems
2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 170 systems
2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 4 systems total for both Disco Sublatar and Twist Sublatar
2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 2 systems
2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 9 systems
2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 4 systems total for both Twist Sublatar and Disco Sublatar
2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 4 systems
2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 17 systems
2018-07-19 Class II Labeling Change Control Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. 28 systems
2016-12-08 Class II Under Investigation by firm Four lots of Tiger Screw Sterilization Tray Base Assemblies were released to the field with a printing error where k-wire description markings indicate diameters of 0.45 and 0.35 instead of 0.045″ and 0.035″, respectively. 50 units 2017-05-17
2016-09-02 Class II Nonconforming Material/Component Screws were identified as having the incorrect part number and lot number marked upon them. The part number incorrectly indicated a length of 115 mm rather than 110 mm. The lot number incorrectly indicated lot number of TSL003765 rather th 11 2017-05-19
2015-07-20 Class II Nonconforming Material/Component The cutting efficiency of the Countersinks was out of specification. 102 units 2017-01-26
2015-07-20 Class II Component design/selection Sterilization tray lids for the Tiger and Tiger Headless Cannulated Screw Systems were reported to occasionally be difficult to remove from the sterilization tray. 71 units 2017-01-26
2009-04-14 Not classified Other Firm received several complaints of field failures, e.g., “broke during surgery” and the firm initiated a design change. A communication to sales staff 04/14/2009 instructed them to recover and reconcile these products from user physicians. 32 units 2010-05-03

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer