5MS™
Compression Drill Guide, Ø1.6 & Ø1.9, Assy
Who Else Makes It
Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone
Record
| Listed by | IN2BONES USA, LLC, United States |
|---|---|
| FDA product code | HWC |
| Device type | Screw, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K170518 |
| Record published | 2017-08-14 |
| Record revised | 2025-11-20 (version 10) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| P60 ST547 | In distribution | |
| P60 ST032 | In distribution | |
| P06 N1031 | In distribution | |
| P62 ST711 | In distribution | |
| P62 ST426 | In distribution | |
| P62 ST408 | In distribution | |
| P64 ST413 | In distribution | |
| P06 N0251 | In distribution | |
| P06 N1032 | In distribution | |
| P06 N1041 | In distribution | |
| P64 ST422 | In distribution | |
| P64 ST430 | In distribution | |
| P64 ST711 | In distribution | |
| P06 N0581 | In distribution | |
| P60 ST565 | In distribution | |
| P62 ST414 | In distribution | |
| P60 ST552 | In distribution | |
| P64 ST722 | In distribution | |
| P60 ST645 | In distribution | |
| P62 ST709 | In distribution | |
| P62 ST718 | In distribution | |
| P60 ST050 | In distribution | |
| P60 ST022 | In distribution | |
| P62 ST713 | In distribution | |
| P06 N1042 | In distribution | |
| P64 ST730 | In distribution | |
| P06 N1012 | In distribution | |
| P60 ST640 | In distribution | |
| P62 ST418 | In distribution | |
| P62 ST430 | In distribution | |
| P64 ST426 | In distribution | |
| P06 N1023 | In distribution | |
| P60 ST542 | In distribution | |
| P60 ST447 | In distribution | |
| P60 ST442 | In distribution | |
| P60 ST012 | In distribution | |
| P64 ST713 | In distribution | |
| P64 ST415 | In distribution | |
| P64 ST411 | In distribution | |
| P60 ST660 | In distribution | |
| P06 N0591 | In distribution | |
| P62 ST722 | In distribution | |
| P64 ST718 | In distribution | |
| P64 ST709 | In distribution | |
| P64 ST715 | In distribution | |
| P62 ST730 | In distribution | |
| P62 ST410 | In distribution | |
| P06 N0011 | In distribution | |
| P64 ST409 | In distribution | |
| P60 ST042 | In distribution | |
| P06 N1024 | In distribution | |
| P64 ST418 | In distribution | |
| P06 N1021 | In distribution | |
| P60 ST470 | In distribution | |
| P62 ST422 | In distribution | |
| P62 ST715 | In distribution | |
| P06 N0141 | In distribution | |
| P60 ST034 | In distribution | |
| P06 N0131 | In distribution | |
| P62 ST412 | In distribution | |
| P62 ST726 | In distribution | |
| P60 ST557 | In distribution | |
| P06 N1011 | In distribution | |
| P60 ST452 | In distribution | |
| P60 ST650 | In distribution | |
| P64 ST726 | In distribution | |
| P06 N1022 | In distribution | |
| P60 ST457 | In distribution | |
| P60 ST670 | In distribution | |
| P60 ST655 | In distribution | |
| P62 ST416 | In distribution | |
| P06 N1051 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Screw, Fixation, Bone | Synthes Gmbh | 3,975 |
| Aptus | Medartis Inc. | 3,623 |
| Acumed | Acumed LLC | 3,187 |
| Arthrex® | Arthrex, Inc. | 2,781 |
| OsteoMed | Osteomed | 2,764 |
| Screw, Fixation, Bone | AAP Implantate AG | 2,176 |
| Screw, Fixation, Bone | Zimmer, Inc. | 1,993 |
| Arix System Bone Screw | Jeil Medical Corporation | 1,875 |
| Cannulated Screw System + | Tyber Medical | 1,814 |
| Cannulated Compression Headless Screw | Tyber Medical | 1,621 |
| Microware Bone Plates and Bone Screws | Microware Precision Co., Ltd. | 1,601 |
| Anthem | Globus Medical, Inc. | 1,538 |
Showing 12 of 5,775. All products under Screw, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K261154 | 2026-05-30 |
| K231236 | 2023-07-27 |
| K180377 | 2018-06-20 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-07-16 | Class II | Process control | CoLink(TM) Lapidus Plate +2mm Right and Left, were laser marked incorrectly. In these lots, right plates were laser marked as left plates and the left plates were laser marked as right plates. | 48 units | 2019-02-22 |
| 2018-07-16 | Class II | Process control | CoLink(TM) Lapidus Plate +2mm Right and Left, were laser marked incorrectly. In these lots, right plates were laser marked as left plates and the left plates were laser marked as right plates. | 47 units | 2019-02-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.