CoverLoc™ Volar Plate
Fully Threaded Screw - Cortical
Who Else Makes It
Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone
Record
| Listed by | Tornier Inc., United States |
|---|---|
| FDA product code | HWC |
| Device type | Screw, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2015-09-25 |
| Record revised | 2025-11-20 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number |
| Sizes | Length 8 to 24 mm; outer diameter 2 to 3.3 mm; width 22 mm |
| Distribution end date | 2022-11-01 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 0011202 | Width 22 mm | Withdrawn |
| 0014124 | Length 24 mm | Withdrawn |
| 0011210 | Length 22 mm | Withdrawn |
| 0014120 | Outer Diameter 2.7 mm | Withdrawn |
| 0013314 | Outer Diameter 3.3 mm | Withdrawn |
| 0011203 | Width 22 mm | Withdrawn |
| 0014114 | Outer Diameter 2.7 mm | Withdrawn |
| 0014820 | Outer Diameter 2.7 mm | Withdrawn |
| 0011217 | Size 22/25 mm | Withdrawn |
| 0014816 | Length 16 mm | Withdrawn |
| 0014818 | Length 18 mm | Withdrawn |
| 0011219 | Size 22/25 mm | Withdrawn |
| 0014322 | Length 22 mm | Withdrawn |
| 0013308 | Length 8 mm | Withdrawn |
| 0014112 | Outer Diameter 2.7 mm | Withdrawn |
| 0014318 | Outer Diameter 2 mm | Withdrawn |
| 0013318 | Length 18 mm | Withdrawn |
| 0011205 | Width 22 mm | Withdrawn |
| 0014824 | Length 24 mm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Screw, Fixation, Bone | Synthes Gmbh | 3,975 |
| Aptus | Medartis Inc. | 3,623 |
| Acumed | Acumed LLC | 3,187 |
| Arthrex® | Arthrex, Inc. | 2,781 |
| OsteoMed | Osteomed | 2,764 |
| Screw, Fixation, Bone | AAP Implantate AG | 2,176 |
| Screw, Fixation, Bone | Zimmer, Inc. | 1,993 |
| Arix System Bone Screw | Jeil Medical Corporation | 1,875 |
| Cannulated Screw System + | Tyber Medical | 1,814 |
| Cannulated Compression Headless Screw | Tyber Medical | 1,621 |
| Microware Bone Plates and Bone Screws | Microware Precision Co., Ltd. | 1,601 |
| Anthem | Globus Medical, Inc. | 1,538 |
Showing 12 of 5,775. All products under Screw, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K150871 | 2015-08-04 |
| K970829 | 1998-12-22 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2010-03-23 | Not classified | Employee error | On 3/9/10 it was discovered that the recalling firm packaged MFT-021-35-24 Screws from lot 0964092 as MFT-021-35-22 lot 0964081. | 62 pieces | 2012-09-10 |
| 2010-01-29 | Class II | Software design (manufacturing process) | The tips of the drivers are breaking while being used to drive the screws into patients. | 120 Pieces | 2013-02-20 |
| 2010-01-29 | Class II | Software design (manufacturing process) | The tips of the drivers are breaking while being used to drive the screws into patients. | 47 Pieces | 2013-02-20 |
| 2009-04-07 | Not classified | Other | A pinhead sized disc was found in the cannulation of a MSD-010-55-60S screw. | 45 pieces | 2010-10-20 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.