DuaFit®
Interphalangeal implants
Who Else Makes It
Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone
Record
| Listed by | In2Bones SAS, France |
|---|---|
| FDA product code | HWC |
| Device type | Screw, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| Establishment | Specification developer, Manufacturer, Exporter |
| 510(k) | K132912 |
| Record published | 2019-11-04 |
| Record revised | 2025-12-15 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Sizes | Angle 0 to 17 °; length 11 to 20 mm |
| Distribution end date | 2024-12-23 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| A60 SP171 B | Angle 17 ° | Withdrawn |
| A60 SP174 B | Angle 17 ° | Withdrawn |
| A60 SP001 B | Angle 0 ° | Withdrawn |
| A60 SP102 B | Angle 10 ° | Withdrawn |
| A60 SP004 B | Length 20 mm | Withdrawn |
| A60 SP101 B | Angle 10 ° | Withdrawn |
| A60 SP003 B | Angle 0 ° | Withdrawn |
| A60 SP002 B | Length 14 mm | Withdrawn |
| A60 SP172 B | Angle 17 ° | Withdrawn |
| A60 SP173 B | Angle 17 ° | Withdrawn |
| A60 SP104 B | Angle 10 ° | Withdrawn |
| A60 SP103 B | Angle 10 ° | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Screw, Fixation, Bone | Synthes Gmbh | 3,975 |
| Aptus | Medartis Inc. | 3,623 |
| Acumed | Acumed LLC | 3,187 |
| Arthrex® | Arthrex, Inc. | 2,781 |
| OsteoMed | Osteomed | 2,764 |
| Screw, Fixation, Bone | AAP Implantate AG | 2,176 |
| Screw, Fixation, Bone | Zimmer, Inc. | 1,993 |
| Arix System Bone Screw | Jeil Medical Corporation | 1,875 |
| Cannulated Screw System + | Tyber Medical | 1,814 |
| Cannulated Compression Headless Screw | Tyber Medical | 1,621 |
| Microware Bone Plates and Bone Screws | Microware Precision Co., Ltd. | 1,601 |
| Anthem | Globus Medical, Inc. | 1,538 |
Showing 12 of 5,775. All products under Screw, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K170688 | 2017-11-28 |
| K170594 | 2017-05-10 |
| K160174 | 2016-10-06 |
| K132912 | 2014-07-30 |
| K131920 | 2014-05-01 |
| K132911 | 2014-04-04 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| In2Bones SAS | 510(k) number | 2015-03-09 | Class II | Nonconforming Material/Component | Dimensional non-conformity leading to the impossibility to introduce the implant in the dedicated holder. | 35 units | 2016-05-19 |
| In2Bones SAS | 510(k) number | 2015-03-09 | Class II | Nonconforming Material/Component | Dimensional non-conformity leading to the impossibility to introduce the implant in the dedicated holder. | 15 units | 2016-05-19 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2024-01-26 | Class II | Process control | This Field Action is being conducted following the identification of a batch mix-up between I.B.S Compression screws diameter 6.5mm length 75mm and I.B.S Compression screws diameter 6.5mm length 80mm. The screws of the batches concerned by | 63 units | |
| 2024-01-26 | Class II | Process control | This Field Action is being conducted following the identification of a batch mix-up between I.B.S Compression screws diameter 6.5mm length 75mm and I.B.S Compression screws diameter 6.5mm length 80mm. The screws of the batches concerned by | 59 units | |
| 2015-11-18 | Class II | Nonconforming Material/Component | One batch of osteosynthesis screws were manufactured with the incorrect Torx imprint on the screw head. | 20 units | 2016-08-19 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.