Imhs
Intramedullary HIP Screw CP Subtrochanteric LAG Screw 12.7MM X 120MM
Who Else Makes It
Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | HWC |
| Device type | Screw, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K040656 |
| Record published | 2015-08-25 |
| Record revised | 2025-02-06 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2018-05-12 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 71683132L | In distribution | |
| 71683632R | In distribution | |
| 71682514L | In distribution | |
| 71683632L | In distribution | |
| 71683538R | In distribution | |
| 71682638R | In distribution | |
| 71683638R | In distribution | |
| 71682638L | In distribution | |
| 71682544L | In distribution | |
| 71684090 | In distribution | |
| 71683134R | In distribution | |
| 71683014R | In distribution | |
| 71661246 | In distribution | |
| 71683144R | In distribution | |
| 71683014L | In distribution | |
| 71683040L | In distribution | |
| 71682636L | In distribution | |
| 71683640R | In distribution | |
| 71684085 | In distribution | |
| 71684075 | In distribution | |
| 71683542L | In distribution | |
| 71684135 | In distribution | |
| 71683138L | In distribution | |
| 71682636R | In distribution | |
| 71684120 | In distribution | |
| 71683532R | In distribution | |
| 71683142L | In distribution | |
| 71682514R | In distribution | |
| 71682734R | In distribution | |
| 71683534R | In distribution | |
| 71682634L | In distribution | |
| 71661250 | In distribution | |
| 71683940 | In distribution | |
| 71661260 | In distribution | |
| 71683040R | In distribution | |
| 71683012L | In distribution | |
| 71683136L | In distribution | |
| 71683032R | In distribution | |
| 71683540R | In distribution | |
| 71683034L | In distribution | |
| 71682512L | In distribution | |
| 71682632L | In distribution | |
| 71684105 | In distribution | |
| 71684125 | In distribution | |
| 71661252 | In distribution | |
| 71682540L | In distribution | |
| 71683544L | In distribution | |
| 71683044R | In distribution | |
| 71683144L | In distribution | |
| 71683512R | In distribution | |
| 71682512R | In distribution | |
| 71661232 | In distribution | |
| 71683016L | In distribution | |
| 71683644R | In distribution | |
| 71661228 | In distribution | |
| 71683514R | In distribution | |
| 71661254 | In distribution | |
| 71683638L | In distribution | |
| 71683140R | In distribution | |
| 71661234 | In distribution | |
| 71683510R | In distribution | |
| 71682540R | In distribution | |
| 71683036R | In distribution | |
| 71682642R | In distribution | |
| 71682544R | In distribution | |
| 71683134L | In distribution | |
| 71684070 | In distribution | |
| 71683510L | In distribution | |
| 71661236 | In distribution | |
| 71683634L | In distribution | |
| 71683542R | In distribution | |
| 71683044L | In distribution | |
| 71683534L | In distribution | |
| 71661264 | In distribution | |
| 71683642L | In distribution | |
| 71661230 | In distribution | |
| 71682510L | In distribution | |
| 71661242 | In distribution | |
| 71682644R | In distribution | |
| 71661224 | In distribution | |
| 71682542L | In distribution | |
| 71661238 | In distribution | |
| 71683012R | In distribution | |
| 71682536R | In distribution | |
| 71661244 | In distribution | |
| 71683038L | In distribution | |
| 71682632R | In distribution | |
| 71683138R | In distribution | |
| 71683516L | In distribution | |
| 71683036L | In distribution | |
| 71683034R | In distribution | |
| 71682532L | In distribution | |
| 71683536R | In distribution | |
| 71661226 | In distribution | |
| 71682640R | In distribution | |
| 71682542R | In distribution | |
| 71682640L | In distribution | |
| 71682532R | In distribution | |
| 71683032L | In distribution | |
| 71683532L | In distribution | |
| 71684140 | In distribution | |
| 71683945 | In distribution | |
| 71683010R | In distribution | |
| 71661240 | In distribution | |
| 71683132R | In distribution | |
| 71682510R | In distribution | |
| 71682516L | In distribution | |
| 71684080 | In distribution | |
| 71683042L | In distribution | |
| 71682642L | In distribution | |
| 71682644L | In distribution | |
| 71684110 | In distribution | |
| 71682538L | In distribution | |
| 71683644L | In distribution | |
| 71683010L | In distribution | |
| 71684130 | In distribution | |
| 71683016R | In distribution | |
| 71683540L | In distribution | |
| 71683136R | In distribution | |
| 71682538R | In distribution | |
| 71683516R | In distribution | |
| 71682516R | In distribution | |
| 71682634R | In distribution | |
| 71661256 | In distribution | |
| 71683038R | In distribution | |
| 71683142R | In distribution | |
| 71661248 | In distribution | |
| 71683642R | In distribution | |
| 71682534R | In distribution | |
| 71682536L | In distribution | |
| 71683634R | In distribution | |
| 71661262 | In distribution | |
| 71683042R | In distribution | |
| 71683140L | In distribution | |
| 71683544R | In distribution | |
| 71684095 | In distribution | |
| 71683538L | In distribution | |
| 71683636R | In distribution | |
| 71683536L | In distribution | |
| 71661258 | In distribution | |
| 71684115 | In distribution | |
| 71683636L | In distribution | |
| 71683514L | In distribution | |
| 71684100 | In distribution | |
| 71683640L | In distribution | |
| 71683512L | In distribution | |
| 71661222 | In distribution | |
| 71682534L | In distribution | |
| 71661695 | Withdrawn | |
| 71664311 | Withdrawn | |
| 71661685 | Withdrawn | |
| 71664128L | Withdrawn | |
| 71663000 | Withdrawn | |
| 71664124L | Withdrawn | |
| 71664409 | Withdrawn | |
| 71664513 | Withdrawn | |
| 71664509 | Withdrawn | |
| 71664126L | Withdrawn | |
| 71664211 | Withdrawn | |
| 71664132L | Withdrawn | |
| 71661700 | Withdrawn | |
| 71663002 | Withdrawn | |
| 71660290 | Withdrawn | |
| 71664413 | Withdrawn | |
| 71664130R | Withdrawn | |
| 71664213 | Withdrawn | |
| 71661680 | Withdrawn | |
| 71660270 | Withdrawn | |
| 71660300 | Withdrawn | |
| 71663005 | Withdrawn | |
| 71664511 | Withdrawn | |
| 71660280 | Withdrawn | |
| 71663003 | Withdrawn | |
| 71664128R | Withdrawn | |
| 71664411 | Withdrawn | |
| 71663006 | Withdrawn | |
| 71663004 | Withdrawn | |
| 71664309 | Withdrawn | |
| 71664132R | Withdrawn | |
| 71664130L | Withdrawn | |
| 71664209 | Withdrawn | |
| 71664126R | Withdrawn | |
| 71664124R | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Screw, Fixation, Bone | Synthes Gmbh | 3,975 |
| Aptus | Medartis Inc. | 3,623 |
| Acumed | Acumed LLC | 3,187 |
| Arthrex® | Arthrex, Inc. | 2,781 |
| OsteoMed | Osteomed | 2,764 |
| Screw, Fixation, Bone | AAP Implantate AG | 2,176 |
| Screw, Fixation, Bone | Zimmer, Inc. | 1,993 |
| Arix System Bone Screw | Jeil Medical Corporation | 1,875 |
| Cannulated Screw System + | Tyber Medical | 1,814 |
| Cannulated Compression Headless Screw | Tyber Medical | 1,621 |
| Microware Bone Plates and Bone Screws | Microware Precision Co., Ltd. | 1,601 |
| Anthem | Globus Medical, Inc. | 1,538 |
Showing 12 of 5,775. All products under Screw, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K233396 | 2023-12-21 |
| K133662 | 2014-05-15 |
| K122596 | 2012-11-20 |
| K111994 | 2011-10-11 |
| K100325 | 2010-05-04 |
| K090656 | 2009-06-03 |
| K082516 | 2008-09-17 |
| K073509 | 2008-03-04 |
| K060736 | 2006-04-18 |
| K053344 | 2006-02-23 |
| K051310 | 2005-07-26 |
| K050226 | 2005-02-11 |
| K040542 | 2004-08-19 |
| K040656 | 2004-05-25 |
| K040331 | 2004-04-14 |
| K032224 | 2003-08-08 |
| K031685 | 2003-07-01 |
| K023021 | 2002-10-04 |
| K020159 | 2002-03-26 |
| K002274 | 2001-03-07 |
| K003599 | 2001-02-15 |
| K994202 | 2000-02-25 |
| K992945 | 1999-11-18 |
| K984320 | 1999-01-28 |
| K980841 | 1998-05-20 |
| K965073 | 1997-02-27 |
| K943539 | 1994-10-19 |
Recalls
11 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-11-24 | Class II | Packaging process control | Removal of affected lot of screws due to labeling error. | 168 units (US 83; OUS 85) | |
| 2021-09-20 | Class II | Process control | The product label incorrectly indicated that the screws are fully threaded, but the screws contained in the package were partially threaded. | 5 units | 2023-03-24 |
| 2018-03-07 | Class II | Under Investigation by firm | One lot of D-RAD Self-Taping Locking Screws used with the Distal Radius Fracture Kit were machined out of specification. Screws measured over tolerance within the head thread form by 0.002-0.003 inch. | 59 units | 2018-10-31 |
| 2017-03-09 | Class II | Labeling Change Control | The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. | 197 units | 2019-08-21 |
| 2017-03-09 | Class II | Labeling Change Control | The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. | 100 units | 2019-08-21 |
| 2017-03-09 | Class II | Labeling Change Control | The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. | 19 units | 2019-08-21 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 43385 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 24574 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 1735 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 240 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 725 US | 2016-04-20 |
| 2012-02-06 | Not classified | Packaging process control | Mislabeled: The device was labeled as a standard thread screw (P/N 72201772) on pouch and box, however the device contained in the packaging is a reverse thread screw (P/N 72201773). | 194 units | 2016-02-29 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 5530 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 6775 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 1274 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2375 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 600 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 6925 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2780 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 1461 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 278 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2903 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 3251 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2357 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 1990 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 3001 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 537 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 7805 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2569 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 275 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 952 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 3791 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 3870 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 4411 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 53 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 500 units | 2012-05-09 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.