Large Cannulated Screws

This bone screw washer is an accessory used with Smith & Nephew cannulated screws during bone fixation. It extends the surface area beneath the screw head when additional support at that…

Registry build 21.09.26

This bone screw washer is an accessory used with Smith & Nephew cannulated screws during bone fixation. It extends the surface area beneath the screw head when additional support at that interface is needed.

The washer is used as part of the compatible screw construct. The system includes screws and associated washers for fracture fixation, reconstruction, osteotomy and joint fusion, with the application selected for the size of the device.

Listed Item

Titanium WASHER-12.7MM Outer Diameter 6.5MM Inner Diameter

Washer Range

The system offers round washers with internal diameters from four to eight millimetres, as well as a butterfly-shaped option. Washers are available in titanium and stainless steel.

31manufacturers in China registered for this device type
23catalogue numbers in this listing
27510(k) clearances naming this product code
36recalls on this code

Who Else Makes It

Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HWC
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11

Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone

Record

Regulatory record for Large Cannulated Screws
Listed by Smith & Nephew, Inc., United States
FDA product code HWC
Device type Screw, Fixation, Bone
Device class Class 2
Regulation 21 CFR 888.3040
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K111994
Record published 2015-09-28
Record revised 2025-11-17 (version 9)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Box of 6
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Large Cannulated Screws
Catalogue number Size Status
71934766 In distribution
71934759 In distribution
71934763 In distribution
71934760 In distribution
71101693 In distribution
71934765 In distribution
71934758 In distribution
71934764 In distribution
71934771 In distribution
71934768 In distribution
71934752 In distribution
71934757 In distribution
71102000 In distribution
71934751 In distribution
71934761 In distribution
71934756 In distribution
71934770 In distribution
71934767 In distribution
71934755 In distribution
71934762 In distribution
71934769 In distribution
71934753 In distribution
71934754 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Screw, Fixation, Bone Synthes Gmbh 3,975
Aptus Medartis Inc. 3,623
Acumed Acumed LLC 3,187
Arthrex® Arthrex, Inc. 2,781
OsteoMed Osteomed 2,764
Screw, Fixation, Bone AAP Implantate AG 2,176
Screw, Fixation, Bone Zimmer, Inc. 1,993
Arix System Bone Screw Jeil Medical Corporation 1,875
Cannulated Screw System + Tyber Medical 1,814
Cannulated Compression Headless Screw Tyber Medical 1,621
Microware Bone Plates and Bone Screws Microware Precision Co., Ltd. 1,601
Anthem Globus Medical, Inc. 1,538

Showing 12 of 5,775. All products under Screw, Fixation, Bone

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K233396 2023-12-21
K133662 2014-05-15
K122596 2012-11-20
K111994 2011-10-11
K100325 2010-05-04
K090656 2009-06-03
K082516 2008-09-17
K073509 2008-03-04
K060736 2006-04-18
K053344 2006-02-23
K051310 2005-07-26
K050226 2005-02-11
K040542 2004-08-19
K040656 2004-05-25
K040331 2004-04-14
K032224 2003-08-08
K031685 2003-07-01
K023021 2002-10-04
K020159 2002-03-26
K002274 2001-03-07
K003599 2001-02-15
K994202 2000-02-25
K992945 1999-11-18
K984320 1999-01-28
K980841 1998-05-20
K965073 1997-02-27
K943539 1994-10-19

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Large Cannulated Screws
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Smith & Nephew, Inc. 510(k) number 2021-09-20 Class II Process control The product label incorrectly indicated that the screws are fully threaded, but the screws contained in the package were partially threaded. 5 units 2023-03-24

Recalls

10 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-11-24 Class II Packaging process control Removal of affected lot of screws due to labeling error. 168 units (US 83; OUS 85)
2018-03-07 Class II Under Investigation by firm One lot of D-RAD Self-Taping Locking Screws used with the Distal Radius Fracture Kit were machined out of specification. Screws measured over tolerance within the head thread form by 0.002-0.003 inch. 59 units 2018-10-31
2017-03-09 Class II Labeling Change Control The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. 197 units 2019-08-21
2017-03-09 Class II Labeling Change Control The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. 100 units 2019-08-21
2017-03-09 Class II Labeling Change Control The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. 19 units 2019-08-21
2013-08-06 Class II Packaging Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. 43385 US 2016-04-20
2013-08-06 Class II Packaging Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. 24574 US 2016-04-20
2013-08-06 Class II Packaging Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. 1735 US 2016-04-20
2013-08-06 Class II Packaging Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. 240 US 2016-04-20
2013-08-06 Class II Packaging Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. 725 US 2016-04-20
2012-02-06 Not classified Packaging process control Mislabeled: The device was labeled as a standard thread screw (P/N 72201772) on pouch and box,
however the device contained in the packaging is a reverse thread screw (P/N 72201773).
194 units 2016-02-29
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 5530 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 6775 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 1274 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 2375 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 600 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 6925 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 2780 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 1461 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 278 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 2903 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 3251 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 2357 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 1990 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 3001 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 537 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 7805 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 2569 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 275 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 952 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 3791 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 3870 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 4411 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 53 units 2012-05-09
2007-08-21 Not classified Nonconforming Material/Component Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. 500 units 2012-05-09

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer