Catalogue number 91-6604, listed by Biomet Microfixation, United States, under Screw, Fixation, Bone. 31 manufacturers in China are registered for this product code.

Registry build 21.09.26
31manufacturers in China registered for this device type
1catalogue number
2510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HWC
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11

Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone

Record

Regulatory record for Rapidfire® System
Listed by Biomet Microfixation, United States
FDA product code HWC
Device type Screw, Fixation, Bone
Device class Class 2
Regulation 21 CFR 888.3040
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K031751
Record published 2015-10-11
Record revised 2025-05-30 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Rapidfire® System
Catalogue number Size Status
91-6604 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Screw, Fixation, Bone Synthes Gmbh 3,975
Aptus Medartis Inc. 3,623
Acumed Acumed LLC 3,187
Arthrex® Arthrex, Inc. 2,781
OsteoMed Osteomed 2,764
Screw, Fixation, Bone AAP Implantate AG 2,176
Screw, Fixation, Bone Zimmer, Inc. 1,993
Arix System Bone Screw Jeil Medical Corporation 1,875
Cannulated Screw System + Tyber Medical 1,814
Cannulated Compression Headless Screw Tyber Medical 1,621
Microware Bone Plates and Bone Screws Microware Precision Co., Ltd. 1,601
Anthem Globus Medical, Inc. 1,538

Showing 12 of 5,775. All products under Screw, Fixation, Bone

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K151173 2015-05-26
K111908 2011-11-29

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Rapidfire® System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2020-11-25 Class II Process control Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device. 7428 2024-05-08

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2010-05-17 Not classified Labeling mix-ups On May 17, 2010, Biomet Microfixation issued a Safety Alert on their Thinflap System Cross Drive, Self Drilling Screw, 1.5x4mm, Model #: 91-6704, Lot#: 173770. The product is labeled incorrectly. Some packages of 91-6704 lot 173770 are labe 927 2011-10-12
2009-09-15 Not classified Component change control Biomet Microfixation is recalling LactoSorb Self Drilling Adjustable Tap Model Numbers 915-2075 Lot # 064350 and 915-2185 Lot # 885580. The two lots identified have a new style stop and an old style tap; they are not compatible, as the dep 15 pieces 2010-01-23
2009-09-15 Not classified Component change control Biomet Microfixation is recalling LactoSorb Self Drilling Adjustable Tap Model Numbers 915-2075 Lot # 064350 and 915-2185 Lot # 885580. The two lots identified have a new style stop and an old style tap; they are not compatible, as the dep 7 pieces 2010-01-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer