Screw, Fixation, Bone
7 X 25 MM RCI Screw Reverse Thread 2.0 MM Cannulation. Sterile, 1 PER BOX.
Who Else Makes It
Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | HWC |
| Device type | Screw, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K240061 |
| Record published | 2015-08-25 |
| Record revised | 2026-04-01 (version 11) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: : – |
| Distribution end date | 2025-06-30 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 71125056 | In distribution | |
| 72700472 | In distribution | |
| 7210040 | In distribution | |
| 71935430 | In distribution | |
| 71106860S | In distribution | |
| 71124080 | In distribution | |
| 71106850S | In distribution | |
| 71109875S | In distribution | |
| 71109300S | In distribution | |
| 71107330S | In distribution | |
| 71106260S | In distribution | |
| 71107550S | In distribution | |
| 71107360S | In distribution | |
| 71935435 | In distribution | |
| 72720570 | In distribution | |
| 71107820S | In distribution | |
| 71106770S | In distribution | |
| 72700540 | In distribution | |
| 71125044 | In distribution | |
| 71126065 | In distribution | |
| 72700570 | In distribution | |
| 72700605 | In distribution | |
| 72720537 | In distribution | |
| 7209410 | In distribution | |
| 6900790 | In distribution | |
| 71108600S | In distribution | |
| 71106330S | In distribution | |
| 72700547 | In distribution | |
| 72720547 | In distribution | |
| 71108660S | In distribution | |
| 71106570S | In distribution | |
| 71106345S | In distribution | |
| 71125032 | In distribution | |
| 71108870S | In distribution | |
| 71109785S | In distribution | |
| 71107665S | In distribution | |
| 71106680S | In distribution | |
| 71109540S | In distribution | |
| 72700520 | In distribution | |
| 72710545 | In distribution | |
| 71935431 | In distribution | |
| 71108795S | In distribution | |
| 72700575 | In distribution | |
| 71109585S | In distribution | |
| 71109375S | In distribution | |
| 71108245S | In distribution | |
| 71108310S | In distribution | |
| 71109310S | In distribution | |
| 71107345S | In distribution | |
| 71108775S | In distribution | |
| 71108765S | In distribution | |
| 71125115 | In distribution | |
| 21-1038 | In distribution | |
| 71107840S | In distribution | |
| 72720535 | In distribution | |
| 71109840S | In distribution | |
| 71106640S | In distribution | |
| 72202232 | In distribution | |
| E0014878-1 | In distribution | |
| 72700495 | In distribution | |
| 71107680S | In distribution | |
| 71106310S | In distribution | |
| 71107860S | In distribution | |
| 7204773 | In distribution | |
| 71106865S | In distribution | |
| 72710590 | In distribution | |
| 71108640S | In distribution | |
| 71124052 | In distribution | |
| 71109565S | In distribution | |
| 71107540S | In distribution | |
| 7204771 | In distribution | |
| 71126090 | In distribution | |
| 71106630S | In distribution | |
| 7209414 | In distribution | |
| 7209415 | In distribution | |
| 71108610S | In distribution | |
| 71126058 | In distribution | |
| 71126048 | In distribution | |
| 71106610S | In distribution | |
| 71935429 | In distribution | |
| 71108655S | In distribution | |
| 72700435 | In distribution | |
| 71106380S | In distribution | |
| 71107760S | In distribution | |
| 71108250S | In distribution | |
| 71106840S | In distribution | |
| 71935425 | In distribution | |
| 71107610S | In distribution | |
| 71109630S | In distribution | |
| 71126028 | In distribution | |
| 7207250 | In distribution | |
| 71107365S | In distribution | |
| 71109575S | In distribution | |
| 72700572 | In distribution | |
| 71107660S | In distribution | |
| 72710460 | In distribution | |
| 71107355S | In distribution | |
| 71125110 | In distribution | |
| 71108785S | In distribution | |
| 71107765S | In distribution | |
| 21-1048 | In distribution | |
| 72710432 | In distribution | |
| 71109250S | In distribution | |
| 71107375S | In distribution | |
| 71108805S | In distribution | |
| 71106815S | In distribution | |
| 71107615S | In distribution | |
| 71126060 | In distribution | |
| 72700455 | In distribution | |
| 72720575 | In distribution | |
| 72710430 | In distribution | |
| 71108855S | In distribution | |
| 72700457 | In distribution | |
| 71126075 | In distribution | |
| 72710445 | In distribution | |
| 71107545S | In distribution | |
| 75006097 | In distribution | |
| 72700477 | In distribution | |
| 72202233 | In distribution | |
| 71935442 | In distribution | |
| 71935436 | In distribution | |
| 71106285S | In distribution | |
| 71107340S | In distribution | |
| 71109665S | In distribution | |
| 7207301 | In distribution | |
| 71124085 | In distribution | |
| 72710522 | In distribution | |
| 72710455 | In distribution | |
| 71101690S | In distribution | |
| 71106845S | In distribution | |
| 71935427 | In distribution | |
| 71106545S | In distribution | |
| 71109610S | In distribution | |
| 71126042 | In distribution | |
| 71106315S | In distribution | |
| 71107370S | In distribution | |
| 71108850S | In distribution | |
| 72710532 | In distribution | |
| 71109590S | In distribution | |
| 71107790S | In distribution | |
| 71126120 | In distribution | |
| 71109580S | In distribution | |
| 71106590S | In distribution | |
| 71108255S | In distribution | |
| 71108650S | In distribution | |
| 71109635S | In distribution | |
| 71107530S | In distribution | |
| 72710420 | In distribution | |
| 72710560 | In distribution | |
| 71109800S | In distribution | |
| 71125042 | In distribution | |
| 71125058 | In distribution | |
| 71101693S | In distribution | |
| 71106780S | In distribution | |
| 71106835S | In distribution | |
| 71126020 | In distribution | |
| 71107855S | In distribution | |
| 72710577 | In distribution | |
| 71125038 | In distribution | |
| 71108620S | In distribution | |
| 71106360S | In distribution | |
| 71108345S | In distribution | |
| 71125070 | In distribution | |
| 71106300S | In distribution | |
| 71107785S | In distribution | |
| 72700465 | In distribution | |
| 72710605 | In distribution | |
| 71107350S | In distribution | |
| 71106775S | In distribution | |
| 71935424 | In distribution | |
| 7204775 | In distribution | |
| 71106575S | In distribution | |
| 71106560S | In distribution | |
| 71126070 | In distribution | |
| 71106600S | In distribution | |
| 71109245S | In distribution | |
| 71107640S | In distribution | |
| 71107645S | In distribution | |
| 72201865 | In distribution | |
| 71109550S | In distribution | |
| 71107245S | In distribution | |
| 71108540S | In distribution | |
| 71107250S | In distribution | |
| 71109645S | In distribution | |
| 72700420 | In distribution | |
| 71106275S | In distribution | |
| 72710555 | In distribution | |
| 72720552 | In distribution | |
| 72720555 | In distribution | |
| 7204765 | In distribution | |
| 71107285S | In distribution | |
| 71108375S | In distribution | |
| 71108365S | In distribution | |
| 71106365S | In distribution | |
| 71109355S | In distribution | |
| 72710422 | In distribution | |
| 71109765S | In distribution | |
| 71124056 | In distribution | |
| 71106550S | In distribution | |
| 71108325S | In distribution | |
| 71106635S | In distribution | |
| 71106565S | In distribution | |
| 71108835S | In distribution | |
| 71108315S | In distribution | |
| 71109805S | In distribution | |
| 71109255S | In distribution | |
| 71108280S | In distribution | |
| 71109675S | In distribution | |
| 71106605S | In distribution | |
| 72720565 | In distribution | |
| 71108645S | In distribution | |
| 71124075 | In distribution | |
| 71126054 | In distribution | |
| 013124D | In distribution | |
| 71107300S | In distribution | |
| 71935438 | In distribution | |
| 71108575S | In distribution | |
| 72700425 | In distribution | |
| 71107315S | In distribution | |
| 7207186 | In distribution | |
| 71125036 | In distribution | |
| 71126036 | In distribution | |
| 71107270S | In distribution | |
| 72710447 | In distribution | |
| 71106620S | In distribution | |
| 71935440 | In distribution | |
| 72710427 | In distribution | |
| 71124120 | In distribution | |
| 72700480 | In distribution | |
| 71107620S | In distribution | |
| 71108570S | In distribution | |
| 72710450 | In distribution | |
| 71109280S | In distribution | |
| 71109600S | In distribution | |
| 71107675S | In distribution | |
| 71124095 | In distribution | |
| 7207249 | In distribution | |
| 71106320S | In distribution | |
| 72202235 | In distribution | |
| 013140 | In distribution | |
| 72700485 | In distribution | |
| 72720572 | In distribution | |
| 71124048 | In distribution | |
| 71125090 | In distribution | |
| 72710435 | In distribution | |
| 72700490 | In distribution | |
| 71109780S | In distribution | |
| 71107570S | In distribution | |
| 7209413 | In distribution | |
| 71106235S | In distribution |
Showing 250 of 300 catalogue numbers.
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Screw, Fixation, Bone | Synthes Gmbh | 3,975 |
| Aptus | Medartis Inc. | 3,623 |
| Acumed | Acumed LLC | 3,187 |
| Arthrex® | Arthrex, Inc. | 2,781 |
| OsteoMed | Osteomed | 2,764 |
| Screw, Fixation, Bone | AAP Implantate AG | 2,176 |
| Screw, Fixation, Bone | Zimmer, Inc. | 1,993 |
| Arix System Bone Screw | Jeil Medical Corporation | 1,875 |
| Cannulated Screw System + | Tyber Medical | 1,814 |
| Cannulated Compression Headless Screw | Tyber Medical | 1,621 |
| Microware Bone Plates and Bone Screws | Microware Precision Co., Ltd. | 1,601 |
| Anthem | Globus Medical, Inc. | 1,538 |
Showing 12 of 5,775. All products under Screw, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K233396 | 2023-12-21 |
| K133662 | 2014-05-15 |
| K122596 | 2012-11-20 |
| K111994 | 2011-10-11 |
| K100325 | 2010-05-04 |
| K090656 | 2009-06-03 |
| K082516 | 2008-09-17 |
| K073509 | 2008-03-04 |
| K060736 | 2006-04-18 |
| K053344 | 2006-02-23 |
| K051310 | 2005-07-26 |
| K050226 | 2005-02-11 |
| K040542 | 2004-08-19 |
| K040656 | 2004-05-25 |
| K040331 | 2004-04-14 |
| K032224 | 2003-08-08 |
| K031685 | 2003-07-01 |
| K023021 | 2002-10-04 |
| K020159 | 2002-03-26 |
| K002274 | 2001-03-07 |
| K003599 | 2001-02-15 |
| K994202 | 2000-02-25 |
| K992945 | 1999-11-18 |
| K984320 | 1999-01-28 |
| K980841 | 1998-05-20 |
| K965073 | 1997-02-27 |
| K943539 | 1994-10-19 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Smith & Nephew, Inc. | 510(k) number | 2021-09-20 | Class II | Process control | The product label incorrectly indicated that the screws are fully threaded, but the screws contained in the package were partially threaded. | 5 units | 2023-03-24 |
Recalls
10 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-11-24 | Class II | Packaging process control | Removal of affected lot of screws due to labeling error. | 168 units (US 83; OUS 85) | |
| 2018-03-07 | Class II | Under Investigation by firm | One lot of D-RAD Self-Taping Locking Screws used with the Distal Radius Fracture Kit were machined out of specification. Screws measured over tolerance within the head thread form by 0.002-0.003 inch. | 59 units | 2018-10-31 |
| 2017-03-09 | Class II | Labeling Change Control | The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. | 197 units | 2019-08-21 |
| 2017-03-09 | Class II | Labeling Change Control | The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. | 100 units | 2019-08-21 |
| 2017-03-09 | Class II | Labeling Change Control | The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. | 19 units | 2019-08-21 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 43385 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 24574 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 1735 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 240 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 725 US | 2016-04-20 |
| 2012-02-06 | Not classified | Packaging process control | Mislabeled: The device was labeled as a standard thread screw (P/N 72201772) on pouch and box, however the device contained in the packaging is a reverse thread screw (P/N 72201773). | 194 units | 2016-02-29 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 5530 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 6775 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 1274 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2375 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 600 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 6925 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2780 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 1461 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 278 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2903 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 3251 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2357 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 1990 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 3001 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 537 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 7805 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 2569 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 275 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 952 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 3791 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 3870 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 4411 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 53 units | 2012-05-09 |
| 2007-08-21 | Not classified | Nonconforming Material/Component | Patient Reaction: Post operative condition sterile fluid pocket has been identified, including the potential for graft failure and premature material degradation. | 500 units | 2012-05-09 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.