Triway

Triway Headed Cotter Screw 5.0 MM Titanium Sterile LG 30 MM

Registry build 21.09.26
31manufacturers in China registered for this device type
25catalogue numbers in this listing
6510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HWC
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11

Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone

Record

Regulatory record for Triway
Listed by In2Bones SAS, France
FDA product code HWC
Device type Screw, Fixation, Bone
Device class Class 2
Regulation 21 CFR 888.3040
Establishment Specification developer, Manufacturer, Exporter
510(k) K173811
Record published 2019-03-06
Record revised 2025-12-15 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Sizes Length 25 to 110 mm; outer diameter 5 mm

Catalogue Numbers

Catalogue numbers for Triway
Catalogue number Size Status
N20 ST550 Length 50 mm In distribution
N20 ST575 Outer Diameter 5 mm In distribution
N20 ST525 Length 25 mm In distribution
N20 ST530 Length 25 mm In distribution
N20 ST730 In distribution
N20 ST535 Outer Diameter 5 mm In distribution
N20 ST555 Outer Diameter 5 mm In distribution
N20 ST722 In distribution
N20 ST610 Length 110 mm In distribution
N20 ST545 Outer Diameter 5 mm In distribution
N20 ST540 Length 40 mm In distribution
N20 ST600 Length 100 mm In distribution
N20 ST560 Length 60 mm In distribution
N20 ST732 In distribution
N20 ST727 In distribution
N20 ST570 Length 70 mm In distribution
N20 ST565 Outer Diameter 5 mm In distribution
N20 ST735 In distribution
N20 ST725 In distribution
N20 ST605 Outer Diameter 5 mm In distribution
N20 ST585 Outer Diameter 5 mm In distribution
N20 ST580 Length 80 mm In distribution
N20 ST720 In distribution
N20 ST590 Length 90 mm In distribution
N20 ST595 Outer Diameter 5 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Screw, Fixation, Bone Synthes Gmbh 3,975
Aptus Medartis Inc. 3,623
Acumed Acumed LLC 3,187
Arthrex® Arthrex, Inc. 2,781
OsteoMed Osteomed 2,764
Screw, Fixation, Bone AAP Implantate AG 2,176
Screw, Fixation, Bone Zimmer, Inc. 1,993
Arix System Bone Screw Jeil Medical Corporation 1,875
Cannulated Screw System + Tyber Medical 1,814
Cannulated Compression Headless Screw Tyber Medical 1,621
Microware Bone Plates and Bone Screws Microware Precision Co., Ltd. 1,601
Anthem Globus Medical, Inc. 1,538

Showing 12 of 5,775. All products under Screw, Fixation, Bone

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K170688 2017-11-28
K170594 2017-05-10
K160174 2016-10-06
K132912 2014-07-30
K131920 2014-05-01
K132911 2014-04-04

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-01-26 Class II Process control This Field Action is being conducted following the identification of a batch mix-up between I.B.S Compression screws diameter 6.5mm length 75mm and I.B.S Compression screws diameter 6.5mm length 80mm.
The screws of the batches concerned by
63 units
2024-01-26 Class II Process control This Field Action is being conducted following the identification of a batch mix-up between I.B.S Compression screws diameter 6.5mm length 75mm and I.B.S Compression screws diameter 6.5mm length 80mm.
The screws of the batches concerned by
59 units
2015-11-18 Class II Nonconforming Material/Component One batch of osteosynthesis screws were manufactured with the incorrect Torx imprint on the screw head. 20 units 2016-08-19
2015-03-09 Class II Nonconforming Material/Component Dimensional non-conformity leading to the impossibility to introduce the implant in the dedicated holder. 35 units 2016-05-19
2015-03-09 Class II Nonconforming Material/Component Dimensional non-conformity leading to the impossibility to introduce the implant in the dedicated holder. 15 units 2016-05-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer