Variable Angle Locking Screw, Low Profile
22 catalogue numbers from FLP 208, listed by Flower Orthopedics Corporation, United States, under Screw, Fixation, Bone. 31 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone
Record
| Listed by | Flower Orthopedics Corporation, United States |
|---|---|
| FDA product code | HWC |
| Device type | Screw, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| 510(k) | K131657 |
| Record published | 2015-09-15 |
| Record revised | 2024-02-19 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Contains natural rubber latex |
| Label carries | lot or batch number, expiry date |
| Sizes | Length 8 to 65 mm; outer diameter 2.7 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| FLP 208 | Length 8 mm | In distribution |
| FLP 224 | Length 24 mm | In distribution |
| FLP 260 | Length 60 mm | In distribution |
| FLP 210 | Length 10 mm | In distribution |
| FLP 236 | Length 36 mm | In distribution |
| FLP 240 | Length 40 mm | In distribution |
| FLP 245 | Length 45 mm | In distribution |
| FLP 218 | Length 18 mm | In distribution |
| FLP 265 | Length 65 mm | In distribution |
| FLP 234 | Length 34 mm | In distribution |
| FLP 212 | Length 12 mm | In distribution |
| FLP 260 | Length 60 mm | In distribution |
| FLP 216 | Length 16 mm | In distribution |
| FLP 228 | Length 28 mm | In distribution |
| FLP 250 | Length 50 mm | In distribution |
| FLP 230 | Length 30 mm | In distribution |
| FLP 238 | Length 38 mm | In distribution |
| FLP 222 | Length 22 mm | In distribution |
| FLP 226 | Length 26 mm | In distribution |
| FLP 214 | Length 14 mm | In distribution |
| FLP 220 | Length 20 mm | In distribution |
| FLP 232 | Length 32 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Screw, Fixation, Bone | Synthes Gmbh | 3,975 |
| Aptus | Medartis Inc. | 3,623 |
| Acumed | Acumed LLC | 3,187 |
| Arthrex® | Arthrex, Inc. | 2,781 |
| OsteoMed | Osteomed | 2,764 |
| Screw, Fixation, Bone | AAP Implantate AG | 2,176 |
| Screw, Fixation, Bone | Zimmer, Inc. | 1,993 |
| Arix System Bone Screw | Jeil Medical Corporation | 1,875 |
| Cannulated Screw System + | Tyber Medical | 1,814 |
| Cannulated Compression Headless Screw | Tyber Medical | 1,621 |
| Microware Bone Plates and Bone Screws | Microware Precision Co., Ltd. | 1,601 |
| Anthem | Globus Medical, Inc. | 1,538 |
Showing 12 of 5,775. All products under Screw, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K170687 | 2017-06-06 |
| K132248 | 2013-10-30 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Flower Orthopedics Corporation DBA Conventus Flower | 510(k) number | 2015-02-16 | Class II | Device Design | Locking pegs were not locking during distal radius procedures. There has been one (1) report of revision surgery scheduled to remove a loosened peg. | 901 | 2015-08-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.