DJO Surgical

Disc Ulna 2.5X53MM LT W/ E+ Brng

Registry build 21.09.26
1manufacturer
74catalogue numbers in this listing

Who Else Makes It

Registered in Shanghai.

Chinese manufacturers registered for FDA product code JDC
Manufacturer City Province Registered as Device types
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106

Record

Regulatory record for DJO Surgical
Listed by Encore Medical, L.P., United States
FDA product code JDC
Device type Prosthesis, Elbow, Constrained, Cemented
Device class Class 2
Regulation 21 CFR 888.3150
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
510(k) K013042
Record published 2017-04-12
Record revised 2025-07-14 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for DJO Surgical
Catalogue number Size Status
540-45-100 In distribution
540-44-150 In distribution
540-34-150 In distribution
540-00-000 In distribution
540-35-100 In distribution
540-35-150 In distribution
540-45-200 In distribution
540-00-001 In distribution
540-44-100 In distribution
540-24-115 In distribution
540-00-004 In distribution
540-63-115 In distribution
540-55-115 In distribution
540-34-100 In distribution
540-15-075 In distribution
540-44-200 In distribution
540-36-100 In distribution
540-64-075 In distribution
540-13-155 In distribution
540-65-115 In distribution
540-23-155 In distribution
540-00-003 In distribution
540-24-075 In distribution
540-46-100 In distribution
540-54-115 In distribution
540-45-150 In distribution
540-23-115 In distribution
540-13-075 In distribution
540-53-115 In distribution
540-00-005 In distribution
540-36-200 In distribution
540-14-075 In distribution
540-53-075 In distribution
540-54-155 In distribution
540-65-075 In distribution
540-15-155 In distribution
540-46-200 In distribution
540-52-053 In distribution
540-33-124 In distribution
540-43-084 In distribution
540-64-155 In distribution
540-23-075 In distribution
540-55-075 In distribution
540-36-150 In distribution
540-52-084 In distribution
540-33-084 In distribution
540-01-001 In distribution
540-22-053 In distribution
540-24-155 In distribution
540-64-115 In distribution
540-12-084 In distribution
540-22-084 In distribution
540-35-200 In distribution
540-25-075 In distribution
540-25-115 In distribution
540-63-075 In distribution
540-53-155 In distribution
540-34-200 In distribution
540-14-155 In distribution
540-01-005 In distribution
540-46-150 In distribution
540-25-155 In distribution
540-00-002 In distribution
540-43-124 In distribution
540-13-115 In distribution
540-62-084 In distribution
540-12-053 In distribution
540-62-053 In distribution
540-15-115 In distribution
540-65-155 In distribution
540-55-155 In distribution
540-54-075 In distribution
540-63-155 In distribution
540-14-115 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Nexel® Zimmer, Inc. 78
Tema Elbow Limacorporate 72
Discovery Elbow System Biomet Orthopedics 72
Arcos Modular Revision Hip System Biomet Orthopedics 58
Latitude™ – Elbow Tornier Inc. 38
Prosthesis, Elbow, Constrained, Cemented Zimmer, Inc. 37
Latitude™ EV Tornier Inc. 36
Comprehensive® SRS Biomet Orthopedics 31
Comprehensive® SRS Instrument Biomet Orthopedics 30
Solar Howmedica Osteonics Corp 27
Zimmer® Nexel® Total Elbow Zimmer, Inc. 23
Arrow Teleflex Medical LLC 13

Showing 12 of 28. All products under Prosthesis, Elbow, Constrained, Cemented

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of DJO Surgical
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2014-05-15 Class II Nonconforming Material/Component Surface finish is different than specified. The implant has 30 grit blast on the exterior of the flange when the print calls for the glass bead blast. The patient may experience pain requiring surgical intervention. 1 2015-03-16
Biomet, Inc. 510(k) number 2011-12-14 Not classified Process change control A Discovery Condyle Kit w/ Hexalobula was opened during an elbow joint replacement surgery, and was found to contain two male condyles. 10 units 2012-12-12
Biomet, Inc. 510(k) number 2011-04-29 Not classified Packaging process control The firm initiated this recall after becoming aware that a Discovery Condyle Kit with Hexalobula contained two male condyles instead of a male and female condyle. 10 KITS 2011-08-29
Biomet, Inc. 510(k) number 2008-05-23 Not classified Packaging process control The component in the package is not the correct size. 6 2009-09-22
Biomet, Inc. 510(k) number 2008-05-23 Not classified Packaging process control The component in the package is not the correct size. 5 2009-09-22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer