ZipFix

Sternal Zipfix With Needle Sterile / 5 Pack

Registry build 21.09.26
5manufacturers in China registered for this device type
4catalogue numbers in this listing

Who Else Makes It

Concentrated in Shanghai (2), Zhejiang (2), Jiangsu (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JDQ
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38

Record

Regulatory record for ZipFix
Listed by Synthes Gmbh, Switzerland
FDA product code JDQ
Device type Cerclage, Fixation
Device class Class 2
Regulation 21 CFR 888.3010
Establishment Specification developer, Manufacturer, Exporter
510(k) K110789
Record published 2015-09-14
Record revised 2023-01-16 (version 7)

Specifications

Specifications
MRI safety MR Safe
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for ZipFix
Catalogue number Size Per pack Status
08.501.001.20S 20 In distribution
08.501.001.01S In distribution
08.501.001.05S 5 In distribution
03.501.080 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Cerclage, Fixation Synthes Gmbh 102
Optilink Synthes Gmbh 61
Songer® Spinal Cable System Pioneer Surgical Technology, Inc. 60
DePuy Songer Spinal Cable System Pioneer Surgical Technology, Inc. 36
Tritium® Sternal Cable Plate System Pioneer Surgical Technology, Inc. 34
Dall-Miles Howmedica Osteonics Corp 22
Sternal Cable System Pioneer Surgical Technology, Inc. 20
Sternal Cable System A & E Medical Corporation 19
Compression Screw System Biomet Orthopedics 18
Accord Smith & Nephew, Inc. 15
Cable-Ready® Zimmer, Inc. 14
Arthrex® Arthrex, Inc. 10

Showing 12 of 56. All products under Cerclage, Fixation

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of ZipFix
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Synthes (USA) Products LLC 510(k) number 2015-10-19 Class II Device Design Certain lots of the Application Instrument for Sternal ZIPFIX that were previously recalled on August 19, 2015 and subsequently repaired and returned to customers between August 26, 2015 and September 23, 2015. The screws on the repaired in 267 2016-08-26
Synthes (USA) Products LLC 510(k) number 2015-07-22 Class II Device Design The end cap may loosen and detach making the instrument non-functional. No injuries reported. 451 2016-08-18
Synthes USA (HQ), Inc. 510(k) number 2013-08-13 Class II Labeling False and Misleading When using the 1st generation Zip Fix Application Instrument it is possible to cut the implant while the tensioning trigger is being squeezed which could lead to loosening of the implant. 319 2016-08-18

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer