U2 Total Knee System

Femoral distal augment trial, right medial/left lateral, #1, 12mm

Registry build 21.09.26
21manufacturers in China registered for this device type
1,078catalogue numbers in this listing
20510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Beijing (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JWH
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Changzhou Wastonortho Medical Appliance Co., Ltd. Changzhou Jiangsu Contract manufacturer 5

Showing 12 of 21. All 21 manufacturers in China registered for Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Record

Regulatory record for U2 Total Knee System
Listed by United Orthopedic Corp., Taiwan
FDA product code JWH
Device type Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
Establishment Contract manufacturer, Manufacturer, Exporter
510(k) K222700
Record published 2022-11-04
Record revised 2022-09-16 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Sizes Height 10 to 17 mm
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for U2 Total Knee System
Catalogue number Size Status
2303-1409 In distribution
2703-6185 In distribution
2203-4040 In distribution
2603-6042-RC In distribution
2323-6051 In distribution
2303-1205 In distribution
2703-6128 PSA, φ23×100mm In distribution
2303-2225-RF CR, plained, #2, 18mm In distribution
2303-1825 #2 In distribution
2623-6362 In distribution
2303-1723 #2 In distribution
9323-8106 In distribution
2303-2453-RF UC, #5, 13mm In distribution
2303-2421-RF UC, #2, 9mm In distribution
2303-1632 11mm In distribution
2623-6213 In distribution
2303-1635 18mm In distribution
2303-4053-RF PS, #5, 13mm In distribution
2303-2223-RF CR, plained, #2, 13mm In distribution
2303-1406 In distribution
2323-6026 In distribution
2303-3571 In distribution
2303-4571 In distribution
2803-6231-RC In distribution
2303-3521 In distribution
2303-1219 Height 16 mm In distribution
2603-6111-RC In distribution
2303-1706 In distribution
2303-1260 #6 In distribution
2303-1737 #3 In distribution
2303-2220-RK In distribution
2303-4075-RF PS, #7, 18mm In distribution
2303-1769 #6 In distribution
2303-1218 #1 In distribution
2303-2226-RF In distribution
2303-2237-RF In distribution
2303-1649 #4 In distribution
9323-8105 In distribution
2303-1231 9mm In distribution
2303-2200-RF In distribution
2303-4031-RF PS, #3, 9mm In distribution
2803-6261-RC In distribution
2703-6147-RA In distribution
2303-1625 18mm In distribution
2123-6160 In distribution
2403-6640 In distribution
2803-6133-RC In distribution
2703-5414 In distribution
2323-6054 In distribution
2803-6161-RC In distribution
2323-6022 In distribution
2303-1679 Height 16 mm In distribution
2303-2220-RF In distribution
2303-1714 #1 In distribution
2303-4547 In distribution
2303-4001 PS, #0, 9mm In distribution
9323-8102 In distribution
2303-2211-RF CR, plained, #1, 9mm In distribution
2303-1242 11mm In distribution
2303-2267-RF In distribution
2123-6140 In distribution
2803-6141-RC In distribution
2303-2229-RK In distribution
2303-1709 In distribution
2303-2218-RF In distribution
2303-4544 In distribution
2303-2429-RK In distribution
2303-1810 #1 In distribution
2303-3535 In distribution
2203-4050-RK In distribution
2303-3607 In distribution
2303-1628 Height 14 mm In distribution
2703-5451 In distribution
2603-6261-RC In distribution
2203-4010-RK In distribution
2303-3563 In distribution
2303-4013-RF PS, #1, 13mm In distribution
2203-4260-RG In distribution
2303-2413-RF UC, #1, 13mm In distribution
2303-2236-RF In distribution
2323-6044 In distribution
2603-6323-RC In distribution
2303-2264-RF CR, plained, #6, 15mm In distribution
2703-6131-RA In distribution
2303-4065-RF PS, #6, 18mm In distribution
2603-6061-RC In distribution
2623-6114 In distribution
2303-1700 In distribution
2803-6152-RC In distribution
2303-1272 #7 In distribution
2303-1819 #1 In distribution
2303-4551 In distribution
2303-2240-RF In distribution
2703-6127 PSA, φ21×100mm In distribution
2703-5461 In distribution
2623-6131 In distribution
2303-2471-RF UC, #7, 9mm In distribution
2703-6081 In distribution
2303-2404-RF In distribution
2303-2215-RF CR, plained, #1, 18mm In distribution
2303-2431-RF UC, #3, 9mm In distribution
2303-4004-RF PS, #0, 15mm In distribution
2323-6043 In distribution
2303-1403 In distribution
2303-1246 Height 10 mm In distribution
2303-2249-RF In distribution
2303-2210-RK In distribution
2303-2246-RF In distribution
2803-6241-RC In distribution
2303-3532 In distribution
2703-5418 In distribution
2303-1771 #7 In distribution
2323-6066 In distribution
9323-8110 In distribution
2303-4549 In distribution
2803-6102-RC In distribution
2303-1702 In distribution
2303-1213 13mm In distribution
2623-6011 In distribution
2303-3576 In distribution
2303-4576 In distribution
2323-6047 In distribution
2303-4507 In distribution
2303-1656 #5 In distribution
2303-3568 In distribution
2303-4005-RF In distribution
2203-4070-RK In distribution
2303-1256 #5 In distribution
2623-6134 In distribution
2303-2212-RF CR, plained, #1, 11mm In distribution
2303-1262 11mm In distribution
2303-4002 PS, #0, 11mm In distribution
2303-2214-RF CR, plained, #1, 15mm In distribution
2303-3540 In distribution
2303-3807 In distribution
2303-1226 Height 10 mm In distribution
9304-8115-RA In distribution
2303-3519 In distribution
2703-6032-RA In distribution
2303-3560 In distribution
2323-6016 In distribution
2303-3508 In distribution
2303-1779 #7 In distribution
2803-6232-RC In distribution
2803-6212-RC In distribution
2323-6056 In distribution
2303-4025-RF PS, #2, 18mm In distribution
2323-6067-RA In distribution
2303-1217 Height 12 mm In distribution
2303-2243-RF CR, plained, #4, 13mm In distribution
2403-6660 In distribution
2303-2255-RF CR, plained, #5, 18mm In distribution
2303-1408 In distribution
2303-3523 In distribution
2303-1675 #7 In distribution
2303-2258-RK In distribution
2203-4140-RG In distribution
2623-6211 In distribution
2323-6041 In distribution
2303-2450-RK In distribution
2803-8112 In distribution
2323-6046 In distribution
2223-6010 In distribution
2323-6017 In distribution
2303-1800 In distribution
2303-3539 In distribution
2303-1630 #3 In distribution
2303-1614 15mm In distribution
2303-1746 #4 In distribution
2303-1210 Height 17 mm In distribution
2623-6364 In distribution
2303-1765 #6 In distribution
2303-4532 In distribution
2303-1817 #1 In distribution
2303-2208-RF In distribution
2603-6152-RC In distribution
2303-1728 #2 In distribution
2303-3604 In distribution
2603-6252-RC In distribution
2623-6121 In distribution
2303-1761 #6 In distribution
2303-4572 In distribution
2303-3506 In distribution
2303-1774 #7 In distribution
2703-6085 In distribution
2303-3562 In distribution
2703-6051-RB In distribution
2303-2405-RF In distribution
2203-4040-RK In distribution
2803-8141 In distribution
2303-2440-RK In distribution
2203-4120-RG In distribution
2303-1711 #1 In distribution
2303-4015-RF PS, #1, 18mm In distribution
2223-6040 In distribution
2303-4516 In distribution
2323-6038 In distribution
2303-4557 In distribution
2623-6032 In distribution
2303-3578 In distribution
2303-1611 9mm In distribution
2303-1753 #5 In distribution
2303-1265 18mm In distribution
2303-4035-RF PS, #3, 18mm In distribution
2703-6184 In distribution
2603-6363-RC In distribution
2303-3577 In distribution
2303-4558 In distribution
9323-5513 In distribution
2803-6213-RC In distribution
2303-1237 Height 12 mm In distribution
2303-4563 In distribution
2303-4073-RF PS, #7, 13mm In distribution
2303-1608 In distribution
2303-1829 #2 In distribution
2303-2201 CR, plained, #0, 9mm In distribution
2603-6012-RC In distribution
2203-4000-RB #0 In distribution
2303-2475-RF UC, #7, 18mm In distribution
2803-6122-RC In distribution
9323-8104 In distribution
2703-5468 In distribution
2703-5454 In distribution
2303-1220 #2 In distribution
2303-1648 Height 14 mm In distribution
2303-2442-RF UC, #4, 11mm In distribution
2623-6112 In distribution
2303-1767 #6 In distribution
2603-6211-RC In distribution
2303-1617 Height 12 mm In distribution
2803-6252-RC In distribution
2303-4560 In distribution
2623-6123 In distribution
2303-1744 #4 In distribution
9323-8107 In distribution
2203-4160-RG In distribution
2303-2233-RF CR, plained, #3, 13mm In distribution
2323-6031 In distribution
2623-6232 In distribution
2303-2239-RF In distribution
2303-4032-RF PS, #3, 11mm In distribution
2303-1229 #2 In distribution
2303-1204 In distribution
2703-6037-RA In distribution
2303-2439-RK In distribution
2303-3567 In distribution
2703-6086 In distribution
2203-4150-RG In distribution
2303-2415-RF UC, #1, 18mm In distribution
2303-1634 15mm In distribution

Showing 250 of 300 catalogue numbers.

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prophecy® Microport Orthopedics Inc. 4,423
Exult Knee Replacement System Corentec Co., Ltd. 1,770
Freedom Maxx Orthopedics Inc. 1,693
Legion Smith & Nephew, Inc. 1,534
MyKnee Medacta International SA 1,466
Journey Smith & Nephew, Inc. 1,339
Persona® Zimmer, Inc. 1,254
DJO Surgical Encore Medical, L.P. 1,131
CKS Plus Shalby Advanced Technologies, Inc. 1,024
Lospa Modular Knee System Corentec Co., Ltd. 1,020
Natural-Knee® Zimmer, Inc. 980
Truliant® Exactech, Inc. 934

Showing 12 of 1,175. All products under Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252725 2025-09-25
K243024 2024-12-20
K222700 2022-10-06
K210961 2021-04-21
K161705 2017-03-16
K161360 2017-02-01
K152430 2016-04-12
K150829 2015-09-25
K140073 2014-06-16
K132752 2014-03-13
K131864 2014-01-15
K131116 2013-10-30
K122183 2013-02-05
K120507 2012-05-04
K103733 2011-08-02
K100981 2010-06-14
K082424 2008-12-16
K082469 2008-09-26
K051640 2006-03-01
K021657 2002-08-12

Recalls Naming This Product

10 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of U2 Total Knee System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
United Orthopedic Corp. 510(k) number 2026-05-20 Class II Process design Due to an incomplete process of the component screw by a subcontractor which prevents the properly assembling of stem trail. 2
United Orthopedic Corp. 510(k) number 2026-05-20 Class II Process design Due to an incomplete process of the component screw by a subcontractor which prevents the properly assembling of stem trail. 2
United Orthopedic Corp. 510(k) number 2024-01-03 Class II Nonconforming Material/Component Their is a potential that the implant curved stem may be oriented incorrectly. 598 units
United Orthopedic Corp. 510(k) number 2024-01-03 Class II Nonconforming Material/Component Their is a potential that the implant curved stem may be oriented incorrectly. 479 units
United Orthopedic Corp. 510(k) number 2024-01-03 Class II Nonconforming Material/Component Their is a potential that the implant curved stem may be oriented incorrectly.
UOC USA Inc. 510(k) number 2021-08-27 Class II Device Design Due to product not meeting specification for concentricity and failing to meet requirements of dynamic fatigue testing. 3 devices 2023-01-20
United Orthopedic Corp. 510(k) number 2017-11-24 Class II Labeling mix-ups UOC received a customer compliant report from our distributor on October 31, 2017
which stated that contents of the package do not match the product labeling.
69 pieces 2018-10-09
United Orthopedic Corp. 510(k) number 2017-11-24 Class II Labeling mix-ups UOC received a customer compliant report from our distributor on October 31, 2017
which stated that contents of the package do not match the product labeling.
14 pieces 2018-10-09
Orthopedic Alliance, LLC 510(k) number 2013-02-20 Class II Labeling design The recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Orthopedic Alliance because the directions for use and surgical techniques were not being provided to every physician
and for every surgery.
459 units 2014-03-26
Orthopedic Alliance, LLC 510(k) number 2013-02-20 Class II Labeling design The recall of the Loaner Bin and Sterilization Trays for implants and instruments was initiated by Orthopedic Alliance because the directions for use and surgical techniques were not being provided to every physician
and for every surgery.
57 units 2014-03-26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer