| 2026-07-06 | Class II | Process change control | The affected Endo-Model replacement set for a Rotating Hinge tibial plateau incorrectly contains a Pure Hinge plateau. The incorrect plateau could lead to a prolonged or modified surgery as the plateau cannot be inserted and an alternative | 1 US; 9 OUS |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 44 units (1 US, 43 OUS) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 4 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 3 units |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 49 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 7 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 4 units (all OUS) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 3 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 8 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 31 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 1 unit (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 2 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 1 unit (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 7 units (OUS only) |
| 2025-11-10 | Class II | Process control | The device has been delivered with a preassembled locking screw that had been inserted from the wrong side into the male taper of the femoral component. | 18 units |
| 2021-03-18 | Class II | Device Design | The firm discovered through customer complaints that device segments may not meet specifications. | 21 units |
| 2021-03-18 | Class II | Device Design | The firm discovered through customer complaints that device segments may not meet specifications. | 13 units |
| 2021-03-18 | Class II | Device Design | The firm discovered through customer complaints that device segments may not meet specifications. | 16 units |
| 2021-03-18 | Class II | Device Design | The firm discovered through customer complaints that device segments may not meet specifications. | 22 units |