Link Endo-Model EVO
Modular Stem, Conical Cemented Stem, 3 mm Offset
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Waldemar Link GmbH & Co. KG, Germany |
|---|---|
| FDA product code | KRO |
| Device type | Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3510 |
| Establishment | Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K202924 |
| Record published | 2021-10-07 |
| Record revised | 2025-06-09 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 15-2951/63 | In distribution | |
| 15-3950/27 | In distribution | |
| 15-2954/02 | In distribution | |
| 15-4613/08 | In distribution | |
| 15-4302/16 | In distribution | |
| 15-2950/15 | In distribution | |
| 15-4313/08 | In distribution | |
| 15-4616/16 | In distribution | |
| 15-4312/12 | In distribution | |
| 15-4613/12 | In distribution | |
| 15-3950/41 | In distribution | |
| 15-2953/00 | In distribution | |
| 15-2953/01 | In distribution | |
| 15-2951/66 | In distribution | |
| 15-3950/32 | In distribution | |
| 15-2951/60 | In distribution | |
| 15-2951/64 | In distribution | |
| 15-4305/08 | In distribution | |
| 15-3950/15 | In distribution | |
| 15-2950/13 | In distribution | |
| 15-3950/25 | In distribution | |
| 15-2951/47 | In distribution | |
| 15-5305/16 | In distribution | |
| 15-2951/56 | In distribution | |
| 15-4614/16 | In distribution | |
| 15-3950/43 | In distribution | |
| 15-3950/28 | In distribution | |
| 15-5605/16 | In distribution | |
| 15-4616/08 | In distribution | |
| 15-2975/18 | In distribution | |
| 15-2958/10 | In distribution | |
| 15-4612/12 | In distribution | |
| 15-6118/29 | In distribution | |
| 15-4605/24 | In distribution | |
| 15-2950/32 | In distribution | |
| 15-3950/36 | In distribution | |
| 15-4311/08 | In distribution | |
| 15-4319/16 | In distribution | |
| 15-4614/08 | In distribution | |
| 15-4605/18 | In distribution | |
| 15-3950/29 | In distribution | |
| 15-5302/16 | In distribution | |
| 15-5604/12 | In distribution | |
| 15-4617/16 | In distribution | |
| 15-2951/55 | In distribution | |
| 15-2950/45 | In distribution | |
| 15-5306/16 | In distribution | |
| 15-4304/24 | In distribution | |
| 15-4320/12 | In distribution | |
| 15-4310/12 | In distribution | |
| 15-3950/22 | In distribution | |
| 15-2958/07 | In distribution | |
| 15-4606/08 | In distribution | |
| 15-2951/79 | In distribution | |
| 15-2954/00 | In distribution | |
| 15-4611/16 | In distribution | |
| 15-4604/18 | In distribution | |
| 15-5604/24 | In distribution | |
| 15-2951/91 | In distribution | |
| 15-2953/08 | In distribution | |
| 15-4620/16 | In distribution | |
| 15-5306/24 | In distribution | |
| 15-5604/08 | In distribution | |
| 15-2958/02 | In distribution | |
| 15-3950/30 | In distribution | |
| 15-5304/24 | In distribution | |
| 15-2951/44 | In distribution | |
| 15-4312/16 | In distribution | |
| 15-4318/16 | In distribution | |
| 15-4619/16 | In distribution | |
| 15-4305/16 | In distribution | |
| 15-2958/12 | In distribution | |
| 15-2958/09 | In distribution | |
| 15-5302/08 | In distribution | |
| 15-5604/16 | In distribution | |
| 15-4606/18 | In distribution | |
| 15-2950/29 | In distribution | |
| 15-2954/10 | In distribution | |
| 15-3950/24 | In distribution | |
| 15-2950/23 | In distribution | |
| 15-2950/42 | In distribution | |
| 15-5606/18 | In distribution | |
| 15-4311/16 | In distribution | |
| 15-4605/08 | In distribution | |
| 15-2950/24 | In distribution | |
| 15-5605/24 | In distribution | |
| 15-2950/14 | In distribution | |
| 15-2950/21 | In distribution | |
| 15-5306/08 | In distribution | |
| 15-4317/08 | In distribution | |
| 15-3950/17 | In distribution | |
| 15-2953/10 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Link Endo-Model EVO Knee System | Waldemar Link GmbH & Co. KG | 324 |
| Endo-Model Modular Knee Prosthesis System | Waldemar Link GmbH & Co. KG | 291 |
| LinkSymphoKnee | Waldemar Link GmbH & Co. KG | 263 |
| Evolution | Microport Orthopedics Inc. | 223 |
| Legion | Smith & Nephew, Inc. | 222 |
| OSS™ Orthopedic Salvage System | Biomet Orthopedics | 211 |
| Ustar II Knee System | United Orthopedic Corp. | 185 |
| “united” Ustar II Knee System | United Orthopedic Corp. | 162 |
| Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer | Zimmer, Inc. | 157 |
| Finn Knee System | Biomet Orthopedics | 138 |
| NexGen | Zimmer, Inc. | 119 |
| Triathlon | Howmedica Osteonics Corp | 106 |
Showing 12 of 109. All products under Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K220628 | 2022-05-03 |
| K211768 | 2021-06-30 |
| K152431 | 2016-05-09 |
| K151008 | 2015-08-26 |
| K143179 | 2015-01-30 |
Recalls Naming This Product
11 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Waldemar Link GmbH & Co. KG | 510(k) number | 2025-07-31 | Class II | Under Investigation by firm | Some modular LinkSymphoKnee TiNbN Tibial Components were manufactured with two uncoated security screws, which is incorrect. | 8 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2025-04-03 | Class II | Nonconforming Material/Component | The device was delivered with a preassembled Femoral Augment screw that was missing its thread. | 1180 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2025-04-03 | Class II | Nonconforming Material/Component | The device was delivered with a preassembled Femoral Augment screw that was missing its thread. | 908 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2025-04-03 | Class II | Nonconforming Material/Component | The device was delivered with a preassembled Femoral Augment screw that was missing its thread. | 441 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2025-04-03 | Class II | Nonconforming Material/Component | The device was delivered with a preassembled Femoral Augment screw that was missing its thread. | 1771 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2025-02-14 | Class II | Labeling Change Control | A problem was discovered during the scanning process of the outer carton label because of an incorrect GTIN on the label, which is a GTIN for a different product. | 37 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2025-02-14 | Class II | Labeling Change Control | A problem was discovered during the scanning process of the outer carton label because of an incorrect GTIN on the label, which is a GTIN for a different product. | 52 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2025-02-14 | Class II | Labeling Change Control | A problem was discovered during the scanning process of the outer carton label because of an incorrect GTIN on the label, which is a GTIN for a different product. | 20 units |
| LinkBio Corp. | 510(k) number | 2023-04-25 | Class II | Under Investigation by firm | Contains the incorrect implant in the packaging. The packaging incorrectly contains the opposite side of the implant (Lateral-Right/Medial-Left instead of Medial-Right/Lateral-Left). | 11 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2022-12-23 | Class II | Component change control | Fixation screw was inserted through the wrong side of the augment (distal to proximal, as opposed to proximal to distal, which is the correct orientation). | 20 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2022-12-23 | Class II | Component change control | Fixation screw was inserted through the wrong side of the augment (distal to proximal, as opposed to proximal to distal, which is the correct orientation). | 20 units |
Recalls
19 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-07-06 | Class II | Process change control | The affected Endo-Model replacement set for a Rotating Hinge tibial plateau incorrectly contains a Pure Hinge plateau. The incorrect plateau could lead to a prolonged or modified surgery as the plateau cannot be inserted and an alternative | 1 US; 9 OUS |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 44 units (1 US, 43 OUS) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 4 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 3 units |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 49 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 7 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 4 units (all OUS) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 3 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 8 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 31 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 1 unit (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 2 units (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 1 unit (OUS only) |
| 2026-01-12 | Class II | Under Investigation by firm | The potential for an implant with a plateau screw where the bushing could detach from the screw shaft due to a longitudinal fracture. | 7 units (OUS only) |
| 2025-11-10 | Class II | Process control | The device has been delivered with a preassembled locking screw that had been inserted from the wrong side into the male taper of the femoral component. | 18 units |
| 2021-03-18 | Class II | Device Design | The firm discovered through customer complaints that device segments may not meet specifications. | 21 units |
| 2021-03-18 | Class II | Device Design | The firm discovered through customer complaints that device segments may not meet specifications. | 13 units |
| 2021-03-18 | Class II | Device Design | The firm discovered through customer complaints that device segments may not meet specifications. | 16 units |
| 2021-03-18 | Class II | Device Design | The firm discovered through customer complaints that device segments may not meet specifications. | 22 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.