OX Legion

Oxinium Legion HK Titanium Tibial Base SZ 5 Left

Registry build 21.09.26
7manufacturers in China registered for this device type
3catalogue numbers in this listing
2510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KRO
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for OX Legion
Listed by Smith & Nephew, Inc., United States
FDA product code KRO
Device type Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3510
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K151118
Record published 2020-06-14
Record revised 2023-09-07 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for OX Legion
Catalogue number Size Status
XK000682-2 In distribution
XK000682-3 In distribution
XK000682-1 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Link Endo-Model EVO Knee System Waldemar Link GmbH & Co. KG 324
Endo-Model Modular Knee Prosthesis System Waldemar Link GmbH & Co. KG 291
LinkSymphoKnee Waldemar Link GmbH & Co. KG 263
Evolution Microport Orthopedics Inc. 223
Legion Smith & Nephew, Inc. 222
OSS™ Orthopedic Salvage System Biomet Orthopedics 211
Ustar II Knee System United Orthopedic Corp. 185
“united” Ustar II Knee System United Orthopedic Corp. 162
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer Zimmer, Inc. 157
Finn Knee System Biomet Orthopedics 138
NexGen Zimmer, Inc. 119
Triathlon Howmedica Osteonics Corp 106

Showing 12 of 109. All products under Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K151118 2015-07-28
K081111 2008-07-23

Recalls

7 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-02-01 Class II Process control The screws package with devices within lot 14AAP6352A were 5 MM instead of 10MM and are too short to be used with the Legion HK Distal Wedge Size 5. 28 units 2018-10-22
2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 16 units 2019-08-16
2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 3 units 2019-08-16
2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 12 units 2019-08-16
2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 10 units 2019-08-16
2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 97 units 2019-08-16
2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 33 units 2019-08-16
2004-06-21 Not classified Other The firm received confirmed reports of Genesis Uni Articular Inserts not locking into tibial base plates intraoperatively. 11,339 units were distributed 2006-02-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer