OX Legion
Oxinium Legion HK Titanium Tibial Base SZ 5 Left
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | KRO |
| Device type | Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3510 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K151118 |
| Record published | 2020-06-14 |
| Record revised | 2023-09-07 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| XK000682-2 | In distribution | |
| XK000682-3 | In distribution | |
| XK000682-1 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Link Endo-Model EVO Knee System | Waldemar Link GmbH & Co. KG | 324 |
| Endo-Model Modular Knee Prosthesis System | Waldemar Link GmbH & Co. KG | 291 |
| LinkSymphoKnee | Waldemar Link GmbH & Co. KG | 263 |
| Evolution | Microport Orthopedics Inc. | 223 |
| Legion | Smith & Nephew, Inc. | 222 |
| OSS™ Orthopedic Salvage System | Biomet Orthopedics | 211 |
| Ustar II Knee System | United Orthopedic Corp. | 185 |
| “united” Ustar II Knee System | United Orthopedic Corp. | 162 |
| Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer | Zimmer, Inc. | 157 |
| Finn Knee System | Biomet Orthopedics | 138 |
| NexGen | Zimmer, Inc. | 119 |
| Triathlon | Howmedica Osteonics Corp | 106 |
Showing 12 of 109. All products under Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K151118 | 2015-07-28 |
| K081111 | 2008-07-23 |
Recalls
7 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-02-01 | Class II | Process control | The screws package with devices within lot 14AAP6352A were 5 MM instead of 10MM and are too short to be used with the Legion HK Distal Wedge Size 5. | 28 units | 2018-10-22 |
| 2016-05-26 | Class II | Process control | The surface inside of the femoral component, where cement is applied for adhesion, is below specification. | 16 units | 2019-08-16 |
| 2016-05-26 | Class II | Process control | The surface inside of the femoral component, where cement is applied for adhesion, is below specification. | 3 units | 2019-08-16 |
| 2016-05-26 | Class II | Process control | The surface inside of the femoral component, where cement is applied for adhesion, is below specification. | 12 units | 2019-08-16 |
| 2016-05-26 | Class II | Process control | The surface inside of the femoral component, where cement is applied for adhesion, is below specification. | 10 units | 2019-08-16 |
| 2016-05-26 | Class II | Process control | The surface inside of the femoral component, where cement is applied for adhesion, is below specification. | 97 units | 2019-08-16 |
| 2016-05-26 | Class II | Process control | The surface inside of the femoral component, where cement is applied for adhesion, is below specification. | 33 units | 2019-08-16 |
| 2004-06-21 | Not classified | Other | The firm received confirmed reports of Genesis Uni Articular Inserts not locking into tibial base plates intraoperatively. | 11,339 units were distributed | 2006-02-15 |