S-ROM Noiles
S-ROM Noiles Rotating Hinge Femoral Rotating Hinge Cemented Right Medium
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Depuy (Ireland), Ireland |
|---|---|
| FDA product code | KRO |
| Device type | Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3510 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K241000 |
| Record published | 2015-09-24 |
| Record revised | 2024-12-09 (version 4) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 62-3401R | In distribution | |
| 62-3411R | In distribution | |
| 62-3411L | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Link Endo-Model EVO Knee System | Waldemar Link GmbH & Co. KG | 324 |
| Endo-Model Modular Knee Prosthesis System | Waldemar Link GmbH & Co. KG | 291 |
| LinkSymphoKnee | Waldemar Link GmbH & Co. KG | 263 |
| Evolution | Microport Orthopedics Inc. | 223 |
| Legion | Smith & Nephew, Inc. | 222 |
| OSS™ Orthopedic Salvage System | Biomet Orthopedics | 211 |
| Ustar II Knee System | United Orthopedic Corp. | 185 |
| “united” Ustar II Knee System | United Orthopedic Corp. | 162 |
| Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer | Zimmer, Inc. | 157 |
| Finn Knee System | Biomet Orthopedics | 138 |
| NexGen | Zimmer, Inc. | 119 |
| Triathlon | Howmedica Osteonics Corp | 106 |
Showing 12 of 109. All products under Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K191779 | 2019-10-08 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Depuy Orthopaedics, Inc. | 510(k) number | 2014-02-24 | Class II | Packaging | DePuy Orthopaedics has identified the potential for holes to develop in the inner and outer flexible pouches that form the sterile barrier for S-ROM Noiles Rotating Hinge Femur with Pin devices. The outer carton and shrink wrap are intact. | 129 | 2015-03-03 |
| Depuy Orthopaedics, Inc. | 510(k) number | 2014-02-24 | Class II | Packaging | DePuy Orthopaedics has identified the potential for holes to develop in the inner and outer flexible pouches that form the sterile barrier for S-ROM Noiles Rotating Hinge Femur with Pin devices. The outer carton and shrink wrap are intact. | 128 | 2015-03-03 |
| Depuy Orthopaedics, Inc. | 510(k) number | 2014-02-24 | Class II | Packaging | DePuy Orthopaedics has identified the potential for holes to develop in the inner and outer flexible pouches that form the sterile barrier for S-ROM Noiles Rotating Hinge Femur with Pin devices. The outer carton and shrink wrap are intact. | 134 | 2015-03-03 |
| Depuy Orthopaedics, Inc. | 510(k) number | 2014-02-24 | Class II | Packaging | DePuy Orthopaedics has identified the potential for holes to develop in the inner and outer flexible pouches that form the sterile barrier for S-ROM Noiles Rotating Hinge Femur with Pin devices. The outer carton and shrink wrap are intact. | 137 | 2015-03-03 |
Recalls
11 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-05-19 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 160 units |
| 2026-05-19 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 66 units |
| 2026-04-03 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 3 units |
| 2026-04-03 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 3 units |
| 2026-04-03 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 3 units |
| 2026-04-03 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 3 units |
| 2026-04-03 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 3 units |
| 2026-04-03 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 3 units |
| 2026-04-03 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 3 units |
| 2026-04-03 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 3 units |
| 2026-04-03 | Class II | Under Investigation by firm | The external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility. | 3 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.