Gender Solutions®
10 catalogue numbers from 00-5926-011-01, listed by Zimmer, Inc., United States, under Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer. 7 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (2). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Record
| Listed by | Zimmer, Inc., United States |
|---|---|
| FDA product code | KRR |
| Device type | Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3540 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K070695 |
| Record published | 2017-10-09 |
| Record revised | 2019-09-25 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 00-5926-011-01 | Size 1 | In distribution |
| 00-5926-013-02 | Size 3 | In distribution |
| 00-5926-014-02 | Size 4 | In distribution |
| 00-5926-012-02 | Size 2 | In distribution |
| 00-5926-012-01 | Size 2 | In distribution |
| 00-5926-014-01 | Size 4 | In distribution |
| 00-5926-015-02 | Size 5 | In distribution |
| 00-5926-013-01 | Size 3 | In distribution |
| 00-5926-011-02 | Size 1 | In distribution |
| 00-5926-015-01 | Size 5 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arthrex® | Arthrex, Inc. | 103 |
| Restoris | Mako Surgical Corp. | 76 |
| Prelude Patello-Femoral System | Biomet Orthopedics | 61 |
| Prelude PF | Biomet Orthopedics | 59 |
| KneeTec PFJ | Corin Limited | 49 |
| HemiCAP® | Arthrosurface, Inc. | 48 |
| Instrument | Howmedica Osteonics Corp | 48 |
| Triathlon | Howmedica Osteonics Corp | 23 |
| Prelude PF | Biomet Sports Medicine | 21 |
| WaveKahuna™ | Arthrosurface, Inc. | 16 |
| HemiCAPWAVE® | Arthrosurface, Inc. | 16 |
| Sigma | Depuy (Ireland) | 16 |
Showing 12 of 47. All products under Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K070695 | 2007-06-07 |
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Zimmer, Inc. | 510(k) number | 2017-11-29 | Class II | Packaging | The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag. | 13,227 in total | 2020-04-02 |
| Zimmer, Inc. | 510(k) number | 2017-11-29 | Class II | Packaging | The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag. | 13,227 in total | 2020-04-02 |
| Zimmer, Inc. | 510(k) number | 2016-01-11 | Class II | Process control | LDPE bag containing the implant adheres to the highly polished implant surface. | 5103 | 2017-05-23 |
| Zimmer, Inc. | 510(k) number | 2014-07-30 | Class II | Nonconforming Material/Component | Internal review found that five (5) PFJ implant forgings were identified as have forged laps during receiving inspection process for raw material. These five forgings were not segregated and were subsequently issued to final manufacturing u | 15 units | 2015-01-20 |
| Zimmer, Inc. | 510(k) number | 2013-08-30 | Class II | Package design/selection | The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices. | 5103 | 2014-09-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.